PNI HS650 Benutzerhandbuch

Typ
Benutzerhandbuch
PNI SafeHouse HS650
Wireless alarm system/ Drahtloses Alarmsystem/Sistema de alarma
inalámbrico/Système d’alarme sans fil/Vezeték nélküli riasztórendszer/
Sistema di allarme senza fili/Draadloos alarmsysteem/Bezprzewodowy
system alarmowy Sistem de alarma wireless
EN User manual ......................................................... 3
BG Ръководство за употреба ............................. 30
DE Benutzerhandbuch .............................................. 61
ES Manual de usuario ............................................... 89
FR Manuel utilisateur ............................................... 117
HU Használati utasítás .............................................. 144
IT Manuale utente .................................................. 171
NL Handleiding ........................................................ 198
PL Instrukcja obsługi ............................................... 225
RO Manual de utilizare ............................................. 253
2
3
English
Warnings
Before using this product, please read the user manual carefully.
The installation and configuration of this alarm system require basic technical
knowledge to allow a correct understanding of the technical terms and
procedures described in this manual.
Follow the step by step instructions and start with simple settings. After making
the settings, test the correct operation of the product.
Main functions
4.3 inch color IPS touch screen
Remote control via Tuya Smart application (Android/iOS)
Menu and voice prompts in 9 languages
Built-in siren, wired indoor siren included in the package and the possibility
of pairing a wireless outdoor siren
Up to 90 wireless zones (sensors) and 3 wired zones (EOLR)
Up to 8 smart sockets or relays
Supports renaming areas, for example: door, bedroom, window, balcony,
living room, smoke sensor, gas sensor, CO sensor, etc.
Low battery warning for sensors
Event log
Alarm alert sent by phone call or SMS on preset phone numbers (up to 5
phone numbers can be set)
Direct phone call via GSM
Built-in tamper
GSM 4G and WiFi communication
Automatic time synchronization via GSM and WiFi
System configuration via SMS
Recorded alarm messages (up to 20 seconds/message)
Remote arming/disarming via Tuya Smart application
Scheduled arming/disarming
3
4
English
General information
Burglary protection
Your alarm system has two modes of protection against burglary: Home arming
and Total arming.
Home arming (perimeter arming) only protects the perimeter, allowing you to
move freely inside the house.
Total arming protects the entire building.
Zones
The sensors paired to your alarm system will be assigned to dierent “zones”
(maximum 90 for wireless sensors and maximum 3 for wired sensors). For
example, the sensor on the front door of the house can be assigned to zone
01, the sensor on the window in the master bedroom in zone 02 and so on. The
zone number is displayed on the screen when an alarm or problem occurs on a
specific area.
Entry and Exit Delay
Your alarm system has been programmed with adjustable delay time that allows
you to leave the house after arming the system and disarm the system at the
entrance into the house, without triggering an alarm.
If you leave the house too late after arming the system or disarm the system
too late after entering the house, the system will trigger an alarm. Disarm the
system immediately.
The alarm and the event notifications on the phone
When an alarm is triggered, the built-in and the external siren will sound until
the system is disarmed or until the preset time interval for the siren expires. A
message will show up on the control panel screen with the area or areas where
the alarm was triggered. If set, the alarm system will call or send SMS via the
4G GSM network to the preset phone numbers (maximum 5) or will send
notification via the mobile application (Tuya Smart).
4
5
English
Alarm system control via Tuya Smart application
Download the Tuya Smart app via Google Play or App Store or scanning the
QR codes below:
Android iOS
Open the application, create an account and log in.
Add your device by clicking the + icon in the upper right corner of the
screen or by clicking the Add device button (this button only appears when
you do not have any devices added to the application).
Select the Sensors option on the left side of the screen.
From the list of devices, select Alarm (Wi-Fi)
Select the WiFi network you want to connect to and add the password.
In the next interface, select the option EZ Mode from the upper right
corner.
Access the alarm system control panel menu WiFi->AirLink Configure
Then tick Confirm the indicator is blinking rapidly. Click Next.
The application will start scanning the nearby devices.
After it identifies your device, you will receive the confirmation Added
Successfully.
To finish, click the button Done.
5
6
English
The application allows you to add accessories (remote controls and sensors), to
configure the system, to arm and disarm, to view the history log.
For details about the menu in the application, please read the explanations of
the alarm menu (page 12).
6
7
English
Main unit
Package contents:
1 x control unit
1 x wireless motion sensor
1 x wireless magnetic sensor
1 x wired indoor siren
2 x remote controls
2 x RFID TAGs
230V - 5V power adapter with USB
USB - microUSB power cable
Mounting accessories
Touchscreen
SOS button
RFID reader
Tamper-switch
7
8
English
SIM slot
Wired zones connection
5V USB
Microphone
On/Off Wired siren connection
SOS button lights
Lighting Meaning
The LED flashes alternately The system is in alarm state
The LED pulses The system is armed
The LED is constantly lit. The system is disarmed
Connecting wired accessories
Zone 1, Zone 2, Zone 3 and Zone 4 are the EOLR wired zones that support
devices (sensors) with NO (open circuit) and NC (closed circuit) signal with
a response time of 300 ms. Maximum resistance of the area: 11000 Ohms +
EOLR
Connect the NC (Normally Closed) devices in series at the top of the loop. The
EOLR resistor must be connected in series with the devices to the last device.
Connect the NO (open circuit) devices in parallel, in the loop.
8
9
English
Wiring diagram
Note: EOLR (End of Line Resistor): If the EOLR resistor is not at the end of the loop,
the area will not be properly monitored and the system may not respond to an open
circuit in the area.
Home screen
123 4 6
7
5
910 11 12
13 14 15 16 17
8
9
10
English
1GSM status
Missing SIM card or defective SIM
card
GPRS - connected to server
RSSI signal level
The signal level is displayed by bars
from 1 to 5 (weak to strong), and
the bars are gray if the system is not
registered in the GSM network
2WiFi status
The system is connected to WiFi. The
number of bars indicates the signal
strength.
The system is connected to the server,
if the point is displayed.
3GSM Outgoing SMS
Outgoing phone call
4Keyboard status Keys locked
5Power supply
The system is powered to 230V
0~3 bars
The system is powered by the built-
in battery. The icon is red when the
battery is discharged.
6Time 15:44 Real time
7Real time
7View system status
messages
Exit delay
Message “Please exit” + Countdown
You have xx seconds to leave the house. When
the time has expired, the alarm system is armed.
10
11
English
7View system status
messages
Entry delay
Message “Please disarm” + Countdown
You must disarm the system before the entry
time expires. If the time has expired and you
have not disarmed, the alarm will sound.
7View system status
messages
Pairing mode
Message “Synchronizing” + Countdown
You must activate the wireless accessory before
the pairing time expires.
7View system status
messages
Message “Alarm” or “Panic Alarm“ is displayed
together with the Zone where the alarm was
triggered.
8Screen lock button
9 Date and day of the week
10 Call Press to access the phone number
dialing interface
11 Arm Press to arm the system
12 Sockets Press to add up to 8 smart sockets
13 Alarm status
The system is fully armed
The system is partially armed
The system is disarmed
13 Log Click to see the arming/disarming history log
14 System status
The system is in normal condition, no
alarm
The system is in alarm, it will also
display the area where the alarm was
triggered
15 Menu Press to access the menu
16 Home arming Press to activate partial (perimeter)
arming
17 Disarming Press to disarm the system
11
12
English
Menu
Settings
Delay
Exit Delay Set the exit delay
Between 0 ~ 65535 sec.
Default:
40 sec.
Entry Delay Set the entry delay
Between 0 ~ 65535 sec.
Default:
30 sec.
Siren Duration Set siren duration
Between 0 ~ 65535 sec.
Default:
3 minutes
Switch
Arm Beep Enable/Disable the beep
when arming/disarming (1)
Default:
Enabled
Siren
Enable/Disable the siren
sound when an alarm
occurs
Default:
Enabled
Arm SMS
Enable/Disable SMS
notification on arming/
disarming
Default:
Disabled
Keypad lock Enable/Disable the key
lock function (2)
Default:
Disabled
Keyboard
Backlight
Enable/Disable
illuminated keys(3)
Default:
Enabled
Keypad tone Enable/Disable key
sound
Default:
Enabled
SOS Enable/Disable SOS
button
Default:
Enabled
12
13
English
Switch
Delay tick
Enable/Disable
countdown sound at
entry or exit
Default:
Enabled
Door/Window
open warning
Enable/Disable open
window/door warning
after arming (4)
Default:
Enabled
Human Voice Enable/Disable voice
prompts
Default:
Enabled
Password
System Change the system
password(5)
Default:
6666
User Change the user
password(6)
Default:
1234
Language
Chinese, English, German, Russian, Spanish,
Polish, Italian, French, Portuguese, Greek,
Romanian (7)
Default:
English
Initialization Return to factory settings. All accessories and parameters
will be deleted.(8)
Phone
1st Phone,
2nd Phone,
3rd Phone,
4th Phone,
5th Phone
Input the phone number and enable or disable calling or
sending an SMS in case of alarm on the respective number
Log
Alarm log Displays the alarm history log
Arm log Displays the history log of arming/disarming the system
13
14
English
Parts
Remote The interface allows you to add, delete a remote control or
delete all remote controls
Detector The interface allows you to add, edit or delete all sensors in
the system
RFID The interface allows you to add, delete a TAG or delete all
RFID TAGs in the system
Siren Learn Send a mating signal to a wireless siren
Alarm Socket AirLink for pairing with a smart socket
Socket On/
O Timer Add a smart plug and set a daily activation program
Decoder Displays the alarm system ID
EOL Zone
EOL Zone 1
Define a name and number of EOLR
zones (wired zones)
EOL Zone 2
EOL Zone 3
EOL Zone 4
WiFi
AirLink
Configure WiFi setup (Requires smartphone app)
Unbind Disconnect the Unit from the server
MAC/IP Display the MAC and IP addresses of the WiFi module
SoftAP
Configure WiFi hotspot connection
14
15
English
Record
Record Audio message recording (sent by calling the preset phone
numbers in case of alarm)
Play Message playback
Delete Delete message
Duration Set message duration, between 0-20 sec. Default:
20 sec.
Timer
Arm Timer Set a daily time for automatic arming
Disarm Timer Set a daily time for automatic disarming
Zone&Sync It is not active.
The time zone can be set via SMS. See page 23
Date&Time Set date and time
Wi-Fi- Sync Turn on/o time synchronization using WiFi
network information
Default:
On
2G/4G Sync Turn on/o time synchronization using the
GSM network information
Default:
On
Version
Displays the firmware version and MAC address of the WiFi module, the
firmware version and IMEI of the GSM module and the serial number of the
central unit.
Footnotes
1. Arming beep: When the function is enabled, the system will announce by a
sound the arming or disarming operation.
2. Key lock: If this function has been enabled, the system will automatically
15
16
English
lock the keyboard if no operation is performed for 30 seconds. To activate the
keyboard, you must enter the user password.
3. Keys backlight: If the function is deactivated, the key backlights turn o
after 30 seconds if no operation is performed.
4. Open door/window warning: If the function is enabled, the system will
generate an warning notification when you open a door or window after the exit
time has elapsed.
5. System password: used to unlock the keypad and make remote settings via
SMS.
6. User password: used to unlock the keypad, as a prefix for remote settings via
SMS and notification for alarm text.
7. Language: the voice prompts and the notification will be in the selected
language. After selecting the desired language, the panel will restart.
8. Initialization: All customized parameters will return to factory defaults and
all paired sensors will be deleted.
Configuration
Power the control unit
Connect the power adapter in the package to the 5V micro USB port and move
the backup battery switch to the “ON” position.
WiFi communication through the integrated module
If your system is configured to report alarms and accept remote control via the
mobile application, the wireless router the alarm system is connected to must
always be on and connected to the Internet.
GSM/4G WiFi communication through the integrated module
If your system is set up to report alarms, receive settings via SMS, or make voice
calls, make sure a SIM card is installed (see image below) and the control panel
is connected to the GSM/4G network. Disable the PIN to the SIM card before
adding it into the unit.
16
17
English
Add and configure phone numbers
You can set up to 5 phone numbers that will receive alarm notifications via SMS
or voice call.
Go to the menu: Phone -> 1st Phone, 2nd Phone, 3rd Phone, 4th Phone,
5th Phone
Phone number: Touch the icon to input the phone number (maximum
18 digits) using the numeric keypad
Phone call: Press twice the icon to select between On and O. If you
select the On option, in the event of an alarm, a voice message will be sent
to that phone number.
SMS: Press twice the icon to select between On and O. If you select
the On option, in case of an alarm, an SMS will be sent to the respective
phone number.
Press the √ key to confirm.
Add/Delete remote controls
Add new remote control
In the main menu, select: Parts->Remote
Press to add a new remote control.
On the screen, the message Synchronising will show up. The system enters
the pairing mode and counts the remaining pairing time (maximum 20
sec.).
Press a button on the remote control to send a signal to the control panel.
On the screen, the message Device code has been learnt will show up if the
remote control was successfully paired.
Delete remote control
In the main menu, select: Parts->Remote
Press next to the remote control you want to delete.
Press the √ key to confirm.
Delete all remote controls
In the main menu, select: Parts->Remote
17
18
English
Press the key to delete all the remote controls.
Press the √ key to confirm.
Add/Delete wireless sensors
Add sensor
In the main menu, select: Parts->Detector
Press the key to add a sensor.
Touch the icon
A
to choose a name for the added sensor.
Touch the icon
24h
to select the working mode of the sensor
Choose between:
Active when perimeter arming - usually assigned to sensors or magnetic
contacts on exterior (perimeter) doors and windows. The sensor is active when
the system is fully armed or partially armed.
Inactive when perimeter arming - usually assigned to a sensor (eg motion
sensor) in an interior area (eg living room, hall, bedroom). The sensor remains
inactive if the system is partially armed.
24 hours active - usually assigned to an area that contains an emergency button,
smoke sensor, CO sensors, flood sensors and gas sensors.
To use the sensor as a doorbell, select Doorbell.
To deactivate the sensor, select Close.
Touch the icon 1 where you will be able to assign a number to that area.
The area number must be unique .
Press the key . The message Synchronising appears on the screen.
The system enters pairing mode and counts the remaining pairing time
(maximum 20 sec.)
Trigger the sensor to send a pairing signal towards the control panel.
After pairing, the message Learning OK will be displayed.
Edit/Delete a sensor
In the main menu, select: Parts->Detector
Click on the number in front of the sensor you want to edit in the list of
sensors. When you have finished editing the name, mode and area number,
press the √ key to confirm.
To delete, Touch the icon next to the sensor you want to delete. Press
the √ key to confirm.
18
19
English
Delete all sensors
In the main menu, select: Parts->Detector
Touch the icon to delete all sensors.
Press the √ key to confirm.
Add/Delete RFID TAGs
Add new TAG
In the main menu, select: Parts-> RFID
Touch the icon to add a TAG
The message Synchronising appears on the screen. The system enters
pairing mode and counts down the remaining pairing time (max. 20 sec.).
Move the TAG closer to the RFID area marked on the control panel.
The screen will display Device code has been learnt if the TAG was
successfully paired.
Delete TAG
In the main menu, select: Parts-> RFID
To delete a TAG, Touch the icon next to the TAG you want to delete.
Press the √ key to confirm.
Delete all TAGs
In the main menu, select: Parts-> RFID
Touch the icon to delete all TAGs.
Press the √ key to confirm.
Pairing a wireless siren
Switch the siren to pairing mode (see the siren user manual). Note: The
wireless siren is not included in this package. Compatible product: Wireless
outdoor siren PNI SafeHouse HS007
In the main menu, select: Parts->Siren Learn
The system sends a signal to the siren. The message Learn signal sent
appears on the screen. The wireless siren will confirm pairing with an audible
or visual signal (see the siren user manual).
19
20
English
Pairing a wireless socket or relay
In the main menu, select: Parts->Alarm Socket
Switch the wireless socket/relay to pairing mode (see the socket/relay
manual). The wireless socket/relay is not included in this package.
Press the key On and Off one at a time. On the screen, the icon
appears. The system sends a signal to the socket/relay twice. The message
Learn signal sent appears on the screen.
The wireless socket/relay will confirm the pairing. For details, refer to the
manual of the wireless socket or relay.
To test whether the wireless device can be opened and closed, press the key
On and Off.
Note: When an audible alarm is triggered, the wireless socket or relay will remain
open until the system is disarmed or the alarm time expires.
Intelligent automation
Wireless socket/relay learning
In the main menu, select: Parts->Socket On/O Timer
Touch the icon to add a new timer for a previously added socket/relay.
Press + and - to choose the socket/relay number and to set the hour (HH)
and minutes (mm).
Press the day or days of the week in which you want the timer to be active.
Click the icon to enable or disable timing.
Press the √ key to confirm.
Note: You can open and close the wireless socket or relay in the Tuya Smart mobile
application.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281

PNI HS650 Benutzerhandbuch

Typ
Benutzerhandbuch