UP56-2111_3
UP56-2121_3
8014176/VD82/2011-07-29
DEOperatingInstructionsTSCH
SafetySpecications
• NosafetycomponentinaccordancewithEUmachine
guidelines.
• Readtheoperatinginstructionsbeforestartingoperation.
Connection,assembly,andsettingsonlybycompetent
technicians.
• Protectthedeviceagainstmoistureandsoilingwhen
operating.
Productdescription
• TheUP56sensormeasuresthelevelinaimmersiontube
upto6baroverpressurecontactless.Withtheprocess
connectionGFunionthesensorcanbeinstalledtothe
immersiontube.Attheanalogueoutputasignalpropor-
tionaltotheleveliscreated.
•ThesurfaceoftheultrasonictranducersoftheUP56sen-
sorsareprotectedbyaPTFEcoating(Teon).Therefore
thesurfaceoftheultrasonictransducercanbecleaned
fromcakingsorspots.
• Thesensorautomaticallydetectstheloadputtothe
analogueoutputandswitchestocurrentoutputorvoltage
outputrespectively.
• Allsettingsaredonewithtwopush-buttonsandathree-
digitLED-display.
• Lightemittingdiodes(three-colourLEDs)indicateall
operationconditions.
• Choosingbetweenrisingandfallingoutputcharacteristic
ispossible.
• Thesensorsareadjustablemanuallyusingthenumerical
LED-displayormaybetrainedusingTeach-inprocesses.
• UsefuladditionalfunctionsaresetintheAdd-on-menu.
• WiththeConnect+,availableasaccessory,allsensor
settingscanbemadeoptionallybyPC.
TheUP56sensorsindicateablindzone,inwhichthedis-
tancecannotbemeasured.Themeasuringrangeindicates
thedistanceofthesensorthatcanbeappliedinnormal
atmosphericpressurewithsufcientfunctionreserve.
SettheparametersofthesensormanuallyorusetheTeach-
inproceduretoadjustthedetectpoints.
T1 D1 D2 T2
Graphic1:TouchControl
Operation
UP56sensorsworkmaintenancefree.Smallamountsofdirt
onthesurfacedonotinuencefunction.Thicklayersofdirt
andcaked-ondirtaffectthesensorfunctionandtherefore
mustberemoved.
Note
•Inprinciple,theuseofultrasonicsensorsforlevelmea-
surementoffoamingliquidsisnotrecommened.Foam
tendstoabsorbultrasonicwaves.Asaconsequencevery
littleoftheultrasonicpulseisreectedbacktothesensor.
• Ifanmediumiswithinthesetwindowmarginsoftheana-
logueoutput,thenLEDD1lightsupgreen,ifthemedium
isoutsidethewindowmargins,thenLEDD1lightsupred.
• Duringnormalmodeoperation,themeasureddistance
valueisdisplayedontheLED-indicatorinmm.Alterna-
tivelyapercentagescalemaybesetintheadd-on-menu.
• IfnoobjectsareplacedwithinthedetectionzonetheLED-
indicatorshows»---«.
• Ifnopush-buttonsarepressedfor20secondsduring
parametersettingmodethemadechangesarestored
andthesensorreturnstonormalmodeoperation.
Showparameters
Tappingpush-buttonT1shortlyduringnormalmodeoperati-
onshows»PAr«ontheLED-display.Eachtimeyoutappush-
buttonT1theactualsettingsoftheanalogueoutputandthe
switchedoutputareshown.
FactorysettingUP56:
• Risinganaloguecharacteristic
• Windowmarginsfortheanalogueoutputsettoblindzone
andmeasuringrange
• Sensitivityatnormalpressureanduseinanimmersion
tube
C
FlowchartforUP56-21_2_3withdisplay
NumericalparameterizationbyLEDdisplay
Add-on-Menü:Additionalfunctions
2T + 1T
1T
2T
2T + 1T
keep T1 and T2 pressed down approx. 13 s until the welcoming
text has passed through and »Add« appears in the LED display
2T + 1T
2T
1T
2T
2T + 1T
nished
» «: display
mm or cm
» «: display
%, 100%
corresponds
to smallest
analogue
value
» «: display
%, 100%
corresponds
to largest
analogue
value
»C01«: bright display
»C02«: display dimmed
»C03«: display o
The highest assigned
sensor address can
be entered optionally
for optimizing multi-
plex speed.
setting range »01«
to »10«
»F00«: no lter
»F01«: standard lter
»F02«: average value
lter
»F03«: foreground-
lter
»F04«: background-
lter
strength of the selec-
ted measurement
value lter
»P00«: weak lter
eect
to
»P09«: strong lter
eect
Inuences the size of
the detection range.
»E01«: high
»E02«: standard
»E03«: low
smallest value:
blind zone
largest value:
window border near
the sensor – 1
power-save mode display mode select current/
voltage output
measurement
value lter
lter strength
foreground
suppression
multiplex operation
device address
multiplex operation
highest address
»Aut«: automatic detec-
tion of the load
»U«: voltage output
»I«: current output
»00«: synchronization
»01« to »10«:
sensor address
for multiplex
operation
»oFF«: synchronization
deactivated
smallest value:
sensor-remote
window border
largest value:
999 mm at
UM30-211113 and
UM30-212113
999 mm at
UM30-213113,
UM30-214113 and
UM30-215113
measurement range calibration display detection range
sensitivity
Level reector, at
least 200 x 200 mm
2
large, aligned at a
right angle to the sen-
sor, position exactly at
a distance of 250 mm
from the sensor with
UM30-211113 and
UM30-212113 and
at exactly a distance
of 900 mm with all
other sensors. Set
250 mm or 900 mm
on the display. Con-
rm calibration by
pressing T1 + T2.
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2
T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1
T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
2T + 1T
1T
2T
2T + 1T
2T
1T
delay time in seconds
at approach of an
object between de-
tection of the object
and output of the dis-
tance value (acts like
a switch-on delay)
»00«: 0 s (no delay)
to
»20«: 20 s response
delay
response delay
2T + 1T
1T
2T + 1T
2T
1
T
Note:
Changes to the settings
in the add-on menu can
hamper the sensor function.
A6, A7, A8, A10, A11, A12
aect the extent of the re-
sponse delay of the sensor.
keep T1 and T2 pressed down approx. 3 s
until the welcoming text has passed through
2 T + 1 T
T2
2 T
1 T
2 T
1 T
2 T + 1 T
set the window border near
the sensor in mm or cm
set the rising( ) / falling ( )
output characteristic
2 T + 1 T
2 T
1 T
2 T + 1 T
2 T + 1 T
set the analogue output
set the sensor-remote window
border in mm or cm
finished
1 T
A
UP56-2112_3/UP56-2122_3
B
L +
Q
A
Sync/Com
2
4
5
NC
n
wht
blk
3
M
blu
gra
1
L+
Q
A
2
4
5
Q
PNP
brn
wht
blk
3
Sync/Com
gra
blu
M
(
2.22)
56.4
(
2.07)
52.7
106
(4.17)
M
12
x1
(0.24)
6.1
(0.41)
10.5
GF D40
(Georg Fischer)
All dimensions in mm (inch)
8014176/VD82/2011-07-29∙PrintedinGermany(GW/KE)∙29-07-2011∙07/11∙Subjecttochangewithoutnotice.∙SICKAG∙Waldkirch∙Germany∙www.sick.com
D
Installationinanimmersiontube:
Theimmersiontubeshould:
• besmoothinside.
• haveaminimuminnerdiameter.
• haveaventhole(ca.2-3mm).
Installationinapressurizedtank:
IftheUP56isusedinapressurizedtank,thesensorgainhastobe
adjusted.Thesensorgain,issetviatheadd-onmenu,sectionA14
under"detectionrangesensitivity".
Type DiameterDRimmersiontube
UP56-21_2_3 >30mm
DR
Graphic2:Installationinanimmersiontube
Pressure range in
the tank
Detectionrangesensitivity
- E01high(pleasedonotuse)
0...3bar E02standard
3...6bar E03low
Inprinciple,thesensitivityshouldbereducedinpressurizedtanks.
IfindoubtchoosevalueE03low.wählen.
ParameterizationbyTeach-in
current
measurement value
current
measurement value
Set analog output
position medium at
press T1 until »IU« appears
position medium at
press T1 until »End« appears
Set the rising/falling
output characteristic
press T1 until the countdown from
»- 8 -« to »- 0 -« nishes;
the symbol appears for
rising/falling characteristic curve.
symbol for rising/
falling characteristic
curve
symbol for rising/
falling characteristic
curve
press T1 to change the output
characteristic
press T1 and T2
until »End« appears
normal operation
teach in the analogue output
1
2
UP56-2112_3 UP56-2122_3
Measuringrangeinaimmersiontube 30mm…450mm 85mm…1500mm
Ultrasonicfrequency 320kHz 320kHz
Resolution 0,025mm 0,18mm
Reproducibility ±0,15% ±0,15%
Accurancy ≤2% ≤2%
SupplyvoltageVS
1)
9VDC…30VDC 9VDC…30VDC
Residualripple ±10% ±10%
Currentconsumption
2)
≤80mA ≤80mA
Responsetime
3)
68ms 84ms
Analogoutput,reversible
4)5)
QA:4mA…20mA/0V…10V QA:4mA…20mA/0V…10V
Switchinghysteresis 3mm 5mm
Standbydelay <300ms <300ms
Connectiontype M12,5-pin M12,5-pin
Enclosurerating IP67 IP67
Ambienttemperature
6)
Operation–25°C...+70°C Operation–25°C...+70°C
Storage–40°C...+85°C Storage–40°C...+85°C
Ultrasonicconvertor PTFE-coating/FFKM PTFE-coating/FFKM
Processconnection GFunionD40 GFunionD40
Pressureresistance/areaofuse 0bar...6bar 0bar...6bar
Weight 210g 210g
Housingmaterial Withoutdisplay:Teon/PTFE,PP Withoutdisplay:Teon/PTFE,PP
Withdisplay:Teon/PTFE,PBT,TPU Withdisplay:Teon/PTFE,PBT,TPU
1)
Reverse-polarityprotected
2)
Withoutload
3)
Recoverytime32ms…180msaccordingtoEMCEN60947-5-7
4)
Short-circuitprotected,reversible
5)
Automaticswitchingbetweenvoltageandcurrentoutputsdependetonload4mA…20mA:RL≤100/at9V≤UB≤20V;RL≤500/atUB≥20V;0…10V:
RL≥100k/atUB≥15V,short-circuitprotected
6)
Temperaturecompensationat–25°C…+50°C,canbeswitchedoff