Pepperl+Fuchs UB6000-30GM-H3-V1 Bedienungsanleitung

Typ
Bedienungsanleitung
Ultraschall-Sensor
Ultrasonic Sensor
Abmessungen
Elektrischer Anschluss/Kurven/
Zusätzliche Informationen
Electrical Connection / Curves / Additional Information
Dimensions
Technische Daten
Technical data
UB6000-30GM-H3-V1
ø74
M30 x 1,5
32,5
110
100
80
19
M12 x 1
5
36
-
ø74
M30 x 1.5
32.5
110
100
80
19
M12 x 1
5
36
Ta k t
Echo
Normsymbol/Anschluss:
2 = Eingang für Sendeimpuls
4 = Ausgang für Echolaufzeit
Adernfarben gemäß EN 60947-5-2.
1
2
3
4
(BN)
(WH)
(BU)
(BK)
+ UB
- UB
U
Steckverbinder V1
2
31
4
Charakteristische Ansprechkurve
Abstand X [m]
Kurve 1: ebene Platte 100 mm x 100 mm
Kurve 2: Rundstab, Ø 25 mm
Abstand Y [m]
1
2
0 1 2 3 4 5 6 7 8 9 10
4
3
2
1
-0
-1
-2
-3
-4
Characteristic response curves
Distance X [m]
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
Distance Y [m]
1
2
0 1 2 3 4 5 6 7 8 9 10
4
3
2
1
-0
-1
-2
-3
-4
Clock
Echo
Standard symbol/Connection:
2 = Emitter pulse input
4 = Echo propagation time output
Core colours in accordance with EN 60947-5-2.
1
2
3
4
(BN)
(WH)
(BU)
(BK)
+ UB
- UB
U
Connector V1
2
31
4
Part. No.:
Date:
130479
12/09/2009 DIN A3 -> DIN
45-1226A
Doc. No.:
Allgemeine Daten
Erfassungsbereich 350 ... 6000 mm
Einstellbereich 400 ... 6000 mm
Blindzone 0 ... 350 mm 1)
Normmessplatte 100 mm x 100 mm
Wandlerfrequenz ca. 65 kHz
Elektrische Daten
Betriebsspannung UB10 ... 30 V DC , Welligkeit 10 %SS
Leerlaufstrom I0 30 mA
Eingang
Eingangstyp 1 Impulseingang für Sendeimpuls (Takt)
0-Pegel (aktiv): < 5 V (UB > 15 V)
1-Pegel (inaktiv): > 10 V ... +UB (UB > 15 V)
0-Pegel (aktiv): < 1/3 UB (10 V < UB < 15 V)
1-Pegel (inaktiv): > 2/3 UB ... +UB (10 V < UB < 15 V)
Impulsdauer 50 ... 700 s (typ. 500 s) 2)
Pausendauer 50 x Impulsdauer
Impedanz 10 kOhm intern mit +UB verbunden
Ausgang
Ausgangstyp 1 Impulsausgang für Echolaufzeit, kurzschlussfest
Open Collector pnp mit pull down Widerstand = 22 k
0-Pegel (kein Echo): -UB
1-Pegel (Echo erkannt): (+UB-2 V)
Bemessungsbetriebsstrom Ie15 mA , kurzschluss-/überlastfest
Temperatureinfluss der Echolaufzeit: 0,17 % /K
Umgebungsbedingungen
Umgebungstemperatur -25 ... 85 °C (248 ... 358 K)
Lagertemperatur -40 ... 85 °C (233 ... 358 K)
Mechanische Daten
Schutzart IP67
Anschluss Gerätestecker V1 (M12 x 1), 4-polig
Material
Gehäuse Messing, vernickelt, Kunststoffteile PBT
Wandler Epoxidharz/Glashohlkugelgemisch; Schaum Polyurethan
Masse 250 g
Normen- und Richtlinienkonformität
Normenkonformität
Normen EN 60947-5-2:2007
IEC 60947-5-2:2007
General specifications
Sensing range 350 ... 6000 mm
Adjustment range 400 ... 6000 mm
Unusable area 0 ... 350 mm 1)
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 65 kHz
Electrical specifications
Operating voltage UB10 ... 30 V DC , ripple 10 %SS
No-load supply current I0 30 mA
Input
Input type 1 pulse input for transmitter pulse (clock)
0-level (active): < 5 V (UB > 15 V)
1-level (inactive): > 10 V ... +UB (UB > 15 V)
0-level (active): < 1/3 UB (10 V < UB < 15 V)
1-level (inactive): > 2/3 UB ... +UB (10 V < UB < 15 V)
Pulse length 50 ... 700 s (typ. 500 s) 2)
Pause length 50 x pulse length
Impedance 10 kOhm internal connected to +UB
Output
Output type 1 pulse output for echo run time, short-circuit proof
open collector pnp with pulldown resistor = 22 kOhm
level 0 (no echo): -UB
level 1 (echo detected): (+UB-2 V)
Rated operational current Ie15 mA , short-circuit/overload protected
Temperature influence the echo propagation time: 0.17 % / K
Ambient conditions
Ambient temperature -25 ... 85 °C (248 ... 358 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Protection degree IP67
Connection V1 connector (M12 x 1), 4-pin
Material
Housing brass, nickel-plated, plastic components PBT
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 250 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
IEC 60947-5-2:2007
Adressen / Addresses / Adresses / Direcciónes / Indirizzi
Contact Pepperl+Fuchs GmbH · 68301 Mannheim · Germany · Tel. +49 621 776-4411 · Fax +49 621 776-27-4411 · E-mail: [email protected]l-fuchs.com
Worldwide Headquarters: Pepperl+Fuchs GmbH · Mannheim · Germany · E-mail: info@de.pepperl-fuchs.com
USA Headquarters: Pepperl+Fuchs Inc. · Twinsburg · USA · E-mail: fa-info@us.pepperl-fuchs.com
Asia Pacific Headquarters: Pepperl+Fuchs Pte Ltd · Singapore · E-mail: [email protected]perl-fuchs.com · Company Registration No. 199003130E
For more contact-adresses refer to the catalogue or internet: http://www.pepperl-fuchs.com
Function
The sensing range is determined in the downstream evaluation electronics such as PLC modules or other existing evaluation units.
The object distance in pulse-echo mode is obtained from the echo time t. The emission of an ultrasonic pulse starts simultaneously with the
falling slope of the clock input signal.
We recommend the usage of a npn-transistor to trigger the sensors clock input. The sensors clock input is connected to the +UB potential
internally by means of a pull up resistor.
1) The unusable area (blind range) BR depends on the pulse duration Ti .
The unusable area reaches a minimum with the shortest pulse duration.
2) The sensors detection range depends on the pulse duration Ti.
With pulse duration < typical pulse duration, the sensors detection range may be reduced.
Clock
Echo
T
i
t
t
t
Clock
Echo
Clock
+ U
B
- U
B
Funktion
Die Ermittlung des Objektabstands erfolgt in einer nachgeschalteten Auswerteelektronik wie z. B. einem SPS-Modul oder einer eigenen
vorhandene Auswerteeinheit.
Der Objektabstand wird im Puls-Echobetrieb aus der Schalllaufzeit t ermittelt. Der Sendeimpuls des Ultraschall-Sensors startet mit der
fallenden Signalflanke am Takteingang des Sensors.
Wir empfehlen, den Takteingang des Sensors mittels eines npn-Transistors anzusteuern, der den Takteingang auf das Potenzial -UB legt. Der
Takteingang des Sensors ist intern über einen Pull-Up-Widerstand mit +UB verbunden.
1) Die Blindzone BR ist abhängig von der Impulsdauer Ti .
Bei kürzerer Impulsdauer ist auch der Blindbereich kleiner.
2) Die Reichweite des Sensors ist abhängig von der Impulsdauer Ti .
Bei einer Impulsdauer < als der typischen Impulsdauer ist mit reduzierter Reichweite zu rechnen.
Takt
Echo
T
i
t
t
t
  • Page 1 1
  • Page 2 2

Pepperl+Fuchs UB6000-30GM-H3-V1 Bedienungsanleitung

Typ
Bedienungsanleitung