FS Managed L2+ Gigabit Switches Benutzerhandbuch

Kategorie
Netzwerk-Switches
Typ
Benutzerhandbuch
V4.0
COMMUTATEURS L2+ GIGABIT GÉRÉS
MANAGED L2+ GIGABIT SWITCHES
MANAGED L2+ GIGABIT SWITCHES
Quick Start Guide
Quick-Start Anleitung
Guide de Démarrage Rapide
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
1
EN
Introduction
Thank you for choosing S3900 Series Stackable Managed Switches. This guide is designed to
familiarize you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
Grounding Cable x1
Power Cord x2 Mounting Bracket x2
M4 Screw x6Rubber Pad x4
Console Cable x1
NOTE: S3900 series switches have dust plugs delivered with them. Keep the dust plugs
properly and use them to protect idle optical ports.
S3900-24F4S
S3900-48T4S
S3900-24T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
2
EN
Hardware Overview
Front Panel Ports
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
RJ45 SFP+
MGT
Console
Ports Description
RJ45
SFP+
SFP
MGT
Console
10/100/1000BASE-T ports for Ethernet connection
SFP ports for 1G connection
SFP+ ports for 1/10G connection
An out-of-band Ethernet management port
An RJ45 console port for serial management
S3900-24T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
SFP SFP+
MGT Console
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
RJ45 SFP+
MGT Console
S3900-24F4S
S3900-48T4S
3
EN
Front Panel Button
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
RESET
Button Description
RESET
Restart: Press and release the Reset button quickly.
Restore to Factory Default Settings: Press and hold the Reset
button for more than ten seconds.
Back Panels
S3900-24T4S
S3900-24T4S/S3900-48T4S
S3900-24F4S
90-264VAC 47-63Hz
90-264VAC 47-63Hz
Dual Power Supplies
Dual Fans Grounding Point
Grounding Point
Dual Power Supplies
90-264VAC 47-63Hz
90-264VAC 47-63Hz
4
EN
Front Panel LEDs
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
SYS
PWR
RJ45
SFP+
LEDs DescriptionStatus
PWR
SYS
RJ45/SFP/SFP+
Green
Green
Green
Blinking Green
System is working properly.
System is not working properly.Off
Off
Switch is powered on.
Data is being transmitted or received.
No device is connected to the corresponding port.
A device is connected to the corresponding port,
but no activity.
S3900-24T4S
S3900-24F4S
S3900-48T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
SFP
SFP+
SYS and PWR
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
SYS and PWR
RJ45
SFP+
5
EN
The installation site must be well ventilated. Ensure that there is adequate air flow around the
switch.
Before you begin the installation, make sure that you have the following:
Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 40°C.
Installation Requirements
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
6
EN
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with six M4 screws.
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
Mounting the Switch
7
EN
2. Attach the switch to the rack using four M6 screws and cage nuts.
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
Grounding the Switch
90-264VAC 47-63Hz
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
8
EN
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other network
devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the Power
90-264VAC 47-63Hz
WARNING: Do not install power cable while the power is on.
S3900-24T4S
123 4 5 6 789 10 11 12
13 14
9
EN
Connecting the SFP+ Ports
1. Plug the compatible SFP+/SFP transceiver into the SFP+ port.
2. Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to
another fiber device.
Connecting the Console Port
1. Insert the RJ45 connector into the RJ45 console port on the front of the switch.
2. Connect the DB9 female connector of the console cable to RS-232 serial port on the computer.
18 19 20 21 22 23 24
25
25
26
26
27
27
28
CONSOLE
MGT
SYS
PWR
RESET
28
Connecting the Management Ports
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical fibers without eye protection.
10
EN
Connecting the MGT Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the MGT port on the front of the switch.
17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
Stacking the S3900 Series Switches
The S3900 series switches support stacking up to 6 switches between the same models together.
Switches in the series can be physically stacked using optical fiber cables connected to SFP+ transceivers,
or 10G Direct Attach Cables (DAC). Only the last two SFP+ ports on the switch can be used for physical
stacking.
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
11
EN
Configuring the Switch Using the Web-based Interface
Configuring the Switch
Welcome to FS Ethernet Switch
English
Sign in
admin
******
Step 1: Connect your computer to the Management port or any Ethernet port of the switch using the
network cable.
Step 2: Set the IP address of the computer to 192.168.1.x.(“x” is any number from 2 to 254.)
?x
OK Cancel
General
IP address:
Subnet ma sk :
Default ga t ew a y :
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4 (TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit A d v anc e d ...
. . .21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS serv er a ddress au tomatically
Use the following DNS server addresses:
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click Sign in to display the web-based configuration page.
12
EN
1. After configuring the stacking, the last two 10G ports will disappear from the configuration file,
which is normal. This design is to prevent misoperation.
2. If using the DAC as the stacking cable, the 1-3m DAC is recommended.
Stacking Configuration Troubleshooting
Configuring the Switch Using the Console Port
Troubleshooting
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the port
mode to adapt or force the port speed to 1G/10G.
10G Port is not Working
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop
bit and no flow control.
Step 4: Enter the default username and password, admin/admin.
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
13
EN
FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
Connecting the Switch Remotely Unsuccessfully
The Port is not Working, the LED Indicator is Off
1. Ensure the switch ports are in the no shutdown state.
2. Check if the switch can read the DDM information.
3. Check if the port speed setting is correct.
4. Try looping the switch cable.
Product Warranty
Warranty: S3900 Series Switches enjoy 4 years limited warranty against defect in materials
or workmanship. For more details about warranty, please check at https://www.fs.com/poli-
cies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
4
14
DE
Einführung
Vielen Dank, dass Sie sich für einen Stackable-Managed-Switch der S3900-Serie entschieden haben.
Diese Anleitung soll Sie mit dem Layout des Switches vertraut machen und beschreibt, wie Sie den
Switch in Ihrem Netzwerk einsetzen.
Zubehör
Erdungskabel x1
Netzkabel x2 Montagehalterung x2
M4-Schraube x6 Gummipad x4
Konsolenkabel x1
HINWEIS: Die Switches der S3900-Serie werden mit Staubschutzkappen geliefert.
Bewahren Sie die Kappen ordnungsgemäß auf und verwenden Sie sie, um ungenutzte
optische Anschlüsse zu schützen.
S3900-24F4S
S3900-48T4S
S3900-24T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
15
DE
Hardware-Übersicht
Anschlüsse an der Vorderseite
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
RJ45 SFP+
MGT
Konsole
Ports Beschreibung
RJ45
SFP+
SFP
MGT
Console
10/100/1000BASE-T-Ports für Ethernet-Anschluss
SFP-Ports für 1G-Verbindung
SFP+-Ports für 1/10G-Verbindung
Ein Out-of-Band-Ethernet-Management-Anschluss
Ein RJ45-Konsolenanschluss für die serielle Verwaltung
S3900-24T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
SFP SFP+
MGT Konsole
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
RJ45 SFP+
MGT Konsole
S3900-24F4S
S3900-48T4S
16
DE
Taste an der Vorderseite
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
RESET
Taste Beschreibung
RESET
Neustart: Drücken Sie die Reset-Taste schnell und lassen Sie sie los.
Auf Werkseinstellungen zurücksetzen: Drücken und halten Sie die
Reset-Taste länger als zehn Sekunden.
Rückseite
S3900-24T4S
S3900-24T4S/S3900-48T4S
S3900-24F4S
90-264VAC 47-63Hz
90-264VAC 47-63Hz
Duale Stromversorgungen
Zwei Lüfter Erdungspunkt
Erdungspunkt
Duale Stromversorgungen
90-264VAC 47-63Hz
90-264VAC 47-63Hz
17
DE
LEDs auf der Vorderseite
S3900-24T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
SYS
PWR
RJ45
SFP+
LEDs BeschreibungStatus
PWR
SYS
RJ45/SFP/SFP+
Grün
Grün
Grün
Blinkt Grün
Das System arbeitet ordnungsgemäß.
Das System arbeitet nicht ordnungsgemäß.Aus
Aus
Der Switch ist eingeschaltet.
Es werden Daten gesendet oder empfangen.
Kein Gerät ist mit dem entsprechenden Anschluss
verbunden.
Ein Gerät ist mit dem entsprechenden Anschluss
verbunden, aber keine Aktivität.
S3900-24T4S
S3900-24F4S
S3900-48T4S
S3900-24F4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21 22 23 24
25 26 27 28
SYS
PWR
CONSOLEMGT
SFP
SFP+
SYS und PWR
S3900-48T4S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLEMGT
SYS
PWR
49 50 51 52
SYS und PWR
RJ45
SFP+
18
DE
Der Aufstellungsort muss gut belüftet sein. Sorgen Sie für eine ausreichende Luftzirkulation
um den Switch.
Bevor Sie mit der Installation beginnen, stellen Sie sicher, dass Sie
Folgendes zur Verfügung haben:
Standortbedingungen:
Betreiben Sie das Gerät nicht in einem Bereich, der eine Umgebungstemperatur von 40°C
überschreitet.
Installationsanforderungen
Kreuzschlitzschraubendreher.
19"-Rack in Standardgröße mit einer Mindesthöhe von 1 HE.
RJ-45-Ethernet-Kabel der Kategorie 5e oder höher für den Anschluss von Netzwerkgeräten.
Der Installationsort muss frei von austretendem oder tropfendem Wasser, starkem Tau und
Feuchtigkeit sein.
Stellen Sie sicher, dass Gestell und Arbeitsplattform gut geerdet sind.
Stellen Sie sicher, dass der Switch eben und stabil steht, um Gefahrensituationen zu vermeiden.
Stellen Sie das Gerät nicht in einer staubigen Umgebung auf.
19
DE
Montage in einem Rack
1. Befestigen Sie die Montagehalterungen mit acht M4-Schrauben an beiden Seiten des Switches.
25
25
26
26
27 28
27
28
SYS
PWR
RESET
CONSOLE
MGT
Bodenmontage
1. Bringen Sie vier Gummipads an der Unterseite an.
2. Stellen Sie das Gehäuse auf den Tisch.
Montage des Switch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

FS Managed L2+ Gigabit Switches Benutzerhandbuch

Kategorie
Netzwerk-Switches
Typ
Benutzerhandbuch