English
Through-beam photoelectric sensor
Operating instructions
Safety notes
• Read the operating instructions before commissioning.
• Connection, mounting, and setting may only be performed by trained
specialists.
• Not a safety component in accordance with the EU Machinery Directive.
• UL: Only for use in applications in accordance with NFPA 79. Adapters
listed by UL with connection cables are available. Enclosure type 1.
• When commissioning, protect the device from moisture and contami-
nation.
• These operating instructions contain information required during the life
cycle of the sensor.
Correct use
The WS / WE100-2 is an opto-electronic through-beam photoelectric sensor
(referred to as "sensor" in the following) for the optical, non-contact de
-
tection of objects, animals, and persons. A sender (WS) and a receiver (WE)
are required for operation. If the product is used for any other purpose or
modied in any way, any warranty claim against SICK AG shall become void.
Commissioning
1 Observe the application conditions: Adjust the distance between the
sender and the receiver according to the corresponding diagram [H]
(x = sensing range, y = operating reserve).
If several through-beam photoelectric sensors which are installed next
to one another are to be used, we recommend swapping the sender /
receiver arrangement at every second through-beam photoelectric
sensor and ensuring that there is sucient distance between the
through-beam photoelectric sensors. By doing this, mutual interfer-
ence can be prevented [cf. H].
2 Mount sensors (sender and receiver) using suitable mounting brackets
(see the SICK range of accessories). Align the sender and receiver with
each other.
Note the sensor's maximum permissible tightening torque of < 0.5 Nm.
3 The sensors must be connected in a voltage-free state (U
B
= 0 V).
The information in the graphics [B] must be observed, depending on
the type of connection:
– Male connector connection: pin assignment
– Cable: core color
Only apply voltage / switch on the power supply (U
B
> 0 V) once all
electrical connections have been completed. The green LED indicator
lights up on the sensor.
Explanations of the connection diagram (graphic B):
Switching output Q (according to graphic B):
WS/WE100-2P (PNP: load -> M)
L = light switching
D = dark switching
4 Align the sender with the receiver. Select the position so that the red
emitted light beam hits the receiver. Tip: Use white paper or a reector
as an alignment aid. The sender must have a clear view of the receiver,
with no object in the path of the beam [see G]. You must ensure that
the optical openings (front screen) of the sensors are completely clear.
5 Sensor with potentiometer:
The sensitivity is adjusted with the potentiometer (type: 270°). Clock-
wise rotation: operating reserve increased; counterclockwise rotation:
operating reserve reduced. We recommend setting the potentiometer
to "Maximum."
The sensor is adjusted and ready for operation. Refer to graphics C
and G to check the function. If the switching output fails to behave in
accordance with graphic C, check application conditions. See section
Fault diagnosis.
Fault diagnosis
Table I indicates which measures are to be taken if the sensor stops
working.
Disassembly and disposal
The sensor must be disposed of according to the applicable country-spe-
cic regulations. Eorts should be made during the disposal process to
recycle the constituent materials (particularly precious metals).
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
– clean the external lens surfaces
– check the screw connections and plug-in connections
No modications may be made to devices.
Subject to change without notice. Specied product properties and
technical data are not written guarantees.
Deutsch
Einweg-Lichtschranke
Betriebsanleitung
Sicherheitshinweise
• Vor der Inbetriebnahme die Betriebsanleitung lesen.
• Anschluss, Montage und Einstellung nur durch Fachpersonal.
• Kein Sicherheitsbauteil gemäß EU-Maschinenrichtlinie.
• UL: Nur zur Verwendung in Anwendungen gemäß NFPA 79.
Von UL gelistete Adapter mit Anschlusskabeln sind verfügbar.
Enclosure type 1.
• Gerät bei Inbetriebnahme vor Feuchte und Verunreinigung schützen.
• Diese Betriebsanleitung enthält Informationen, die während des
Lebenszyklus des Sensors notwendig sind.
Bestimmungsgemäße Verwendung
Die WS / WE100-2 ist eine optoelektronische Einweg-Lichtschranke (im
Folgenden Sensor genannt) und wird zum optischen, berührungslosen
Erfassen von Sachen, Tieren und Personen eingesetzt. Zum Betrieb ist ein
Sender (WS) und ein Empfänger (WE) erforderlich. Bei jeder anderen Ver-
wendung und bei Veränderungen am Produkt verfällt jeglicher Gewährleis-
tungsanspruch gegenüber der SICK AG.
Inbetriebnahme
1 Einsatzbedingungen beachten: Distanz zwischen Sender und
Empfänger mit dem zugehörigen Diagramm [vgl. H] abgleichen
(x = Schaltabstand, y = Funktionsreserve).
Beim Einsatz von mehreren Einweg-Lichtschranken, die nebenein-
ander installiert werden, empfehlen wir, bei jeder zweiten Ein-
weg-Lichtschranke die Anordnung von Sender und Empfänger zu tau-
schen, bzw. genügend Abstand zwischen den Einweg-Lichtschranken
einzuhalten. Damit können gegenseitige Beeinussungen vermieden
werden [vgl. H].
2 Sensoren (Sender und Empfänger) an geeignete Befestigungswinkel
montieren (siehe SICK-Zubehör-Programm). Sender und Empfänger
zueinander ausrichten.
Maximal zulässiges Anzugsdrehmoment des Sensors von < 0.5 Nm
beachten.
3 Anschluss der Sensoren muss spannungsfrei (U
B
= 0 V) erfolgen.
Je nach Anschlussart sind die Informationen in den Graken [vgl. B]
zu beachten:
– Steckeranschluss: Pinbelegung
– Leitung: Adernfarbe
Erst nach Anschluss aller elektrischen Verbindungen die Span-
nungsversorgung (U
B
> 0 V) anlegen bzw. einschalten. Am Sensor
leuchtet die grüne Anzeige-LED.
WS / WE100-2X1xxx
-2X3xxx
-2X4xxx
WS / WE100-2
5
(16.4)
10
(31.8)
15
(49.2)
100
10
1
20
(65.6)
25
(82.0)
30
(98.4)
35
1
2
Sensing range
3
With slotted mask, width 2.0 mm
With slotted mask, width 1.0 mm
3 With slotted mask, width 0.5 mm
Erläuterungen zum Anschlussschema (Grak B):
Schaltausgang Q (gemäß Grak B):
WS / WE100-2P (PNP: Last -> M)
L = hellschaltend
D = dunkelschaltend
4 Sender auf Empfänger ausrichten. Positionierung so wählen, dass der
rote Sendelichtstrahl auf den Empfänger auftrit. Tipp: Weißes Papier
oder Reektor als Ausrichthilfe verwenden. Der Sender muss freie
Sicht auf den Empfänger haben, es darf sich kein Objekt im Strahlen-
gang benden [vgl. G]. Es ist darauf zu achten, dass die optischen
Önungen (Frontscheiben) der Sensoren vollständig frei sind.
5 Sensor mit Potentiometer:
Mit dem Potentiometer (Art: 270°) wird die Empndlichkeit
eingestellt. Drehung nach rechts: Erhöhung der Funktionsreserve, Dre-
hung nach links: Verringerung der Funktionsreserve. Wir empfehlen,
das Potentiometer auf "Maximal" zu stellen.
Sensor ist eingestellt und betriebsbereit. Zur Überprüfung der Funktion
Grak C und G heranziehen. Verhält sich der Schaltausgang nicht gemäß
Grak C, Einsatzbedingungen prüfen. Siehe Abschnitt Fehlerdiagnose.
Fehlerdiagnose
Tabelle I zeigt, welche Maßnahmen durchzuführen sind, wenn die Funktion
des Sensors nicht mehr gegeben ist.
Demontage und Entsorgung
Die Entsorgung des Sensors hat gemäß den länderspezisch anwendbaren
Vorschriften zu erfolgen. Für die enthaltenen Wertstoe (insbesondere
Edelmetalle) ist im Rahmen der Entsorgung eine Verwertung anzustreben.
Wartung
SICK-Sensoren sind wartungsfrei.
Wir empfehlen, in regelmäßigen Abständen
– die optischen Grenzächen zu reinigen
– Verschraubungen und Steckverbindungen zu überprüfen
Veränderungen an Geräten dürfen nicht vorgenommen werden.
Irrtümer und Änderungen vorbehalten. Angegebene Produkteigenschaften
und technische Daten stellen keine Garantieerklärung dar.
Anzeige-LED / Fehlerbild /
LED indicator / fault pattern
Ursache /
Cause
Maßnahme /
Measures
grüne LED leuchtet nicht bzw. flackert /
green LED does not light up or flickers
Sensor ist noch betriebsbereit, aber die Betriebsbe-
dingungen sind nicht optimal (Funktionsreservefaktor
zwischen 0,9 und 1,1) /
Sensor is still ready for operation, but the operating
conditions are not ideal (operating reserve factor
between 0.9 and 1.1)
Betriebsbedingungen prüfen: Lichtstrahl (Lichtfleck)
vollständig auf den Reflektor ausrichten / Reinigung
der optischen Flächen (Sensor und Reflektor) /
Empfindlichkeit (Potentiometer) neu einstellen / falls
Potentiometer auf max. Schaltabstand eingestellt:
Abstand zwischen Sensor und Reflektor verringern
sowie Reflektortyp mit Grafik H überprüfen /
Reflektor eignet sich nicht für gewählte Applikation
(wir empfehlen, ausschließlich SICK-Reflektoren zu
verwenden) / Schaltabstand überprüfen und ggf.
anpassen, siehe Grafik H /
Check the operating conditions: Fully align the beam
of light (light spot) with the reflector / Clean the optical
surfaces (sensor and reflector) / Readjust the sensi
-
tivity (potentiometer) / If the potentiometer is set to
the max. sensing range: Reduce the distance between
the sensor and the reflector, and check the reflector
type against graphic H / Reflector is not suitable for
the application in question (we recommend only using
SICK reflectors) / Check sensing range and adjust if
necessary; see graphic H
grüne LED leuchtet nicht /
green LED does not light up
keine Spannung oder Spannung unterhalb der
Grenzwerte /
no voltage or voltage below the limit values
Spannungsversorgung prüfen, den gesamten elektri
-
schen Anschluss prüfen (Leitungen und Steckerver-
bindungen) /
Check the power supply, check all electrical connec-
tions (cables and plug connections)
grüne LED leuchtet nicht /
green LED does not light up
Spannungsunterbrechungen /
Voltage interruptions
Sicherstellen einer stabilen Spannungsversorgung
ohne Unterbrechungen /
Ensure there is a stable power supply without
interruptions
grüne LED leuchtet nicht /
green LED does not light up
Sensor ist defekt /
Sensor is faulty
Wenn Spannungsversorgung in Ordnung ist, dann
Sensor austauschen /
If the power supply is OK, replace the sensor
gelbe LED leuchtet, kein Objekt im Strahlengang /
yellow LED lights up, no object in the path of the beam
Der Lichtstrahl einer Einweg-Lichtschranke trifft
auf den Empfänger einer anderen (benachbarten)
Einweg-Lichtschranke /
The beam of light of a photoelectric through-beam
sensor hits the receiver of another (neighboring)
photoelectric through-beam sensor
Bei jeder zweiten Einweg-Lichtschranke die Anordnung
von Sender und Empfänger tauschen, bzw. genügend
Abstand zwischen den Einweg-Lichtschranken
einhalten /
Swap the sender and receiver arrangement at every
second photoelectric through-beam sensor and ensure
that there is sufficient distance between the through-
beam photoelectric sensors
WS / WE100-2
Sensing range
(with reflector PL80A)
Schaltabstand
(mit Reflektor PL80A)
Portée
(avec réflecteur PL80A)
Distância de comutação
(com refletor PL80A)
0 ... 20 m
Sensing range max.
(with reflector PL80A)
Schaltabstand max.
(mit Reflektor PL80A)
Portée max.
(avec réflecteur PL80A)
Distância de comutação max.
(com refletor PL80A)
0 ... 33 m
Light spot diameter / distance Lichtfleckdurchmesser / Entfernung Diamètre spot / distance Diâmetro do ponto de luz / distância 1,800 mm / 25 m
Supply voltage U
B
Versorgungsspannung U
B
Tension d'alimentation U
B
Tensão de alimentação U
B
DC 10 ... 30 V
1)
Output current I
max.
Ausgangsstrom I
max.
Courant de sortie I
max.
Corrente de saída I
max.
100 mA
Max. switching frequency Schaltfolge max. Commutation max. Sequência max. de comutação 1000 Hz
2)
Max. response time Ansprechzeit max. Temps de réponse max. Tempo max. de resposta ≤ 0.5 ms
3)
Enclosure rating Schutzart Indice de protection Tipo de proteção IP 67
Protection class Schutzklasse Classe de protection Classe de proteção
Circuit protection Schutzschaltungen Protections électriques Circuitos de proteção A,B,D
4)
Ambient operating temperature Betriebsumgebungstemperatur Température de service Temperatura ambiente de funcionamento -25 ... +55°C
1)
Limit value:
operation in short-circuit protection mains max. 8 A;
residual ripple max. ± 10 %
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
A = U
B
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
1)
Grenzwerte:
Betrieb im kurzschlussgeschützten Netz max. 8 A;
Restwelligkeit max. ± 10 %
2)
Mit Hell- / Dunkelverhältnis 1:1
3)
Signallaufzeit bei ohmscher Last
4)
A = U
B
-Anschlüsse verpolsicher
B = Ein- und Ausgänge verpolsicher
D = Ausgänge überstrom- und kurzschlussfest
1)
Valeurs limites :
fonctionnement sur réseau protégé contre les courts-circuits max. 8 A ;
ondulation résiduelle max. ± 10 %
2)
Pour un rapport clair / sombre de 1:1
3)
Temps de propagation du signal sur charge ohmique
4)
A = raccordements U
B
protégés contre les inversions de polarité
B = entrées et sorties protégées contre les inversions de polarité
D = sorties protégées contre les courts-circuits et les surcharges
1)
Valores limite:
funcionamento com rede à prova de curto-circuito max. 8 A;
ondulação residual max. ± 10 %
2)
Com proporção sombra / luz 1:1
3)
Tempo de funcionamento do sinal com carga ôhmica
4)
A = conexões protegidas contra inversão de pólos U
B
B = entradas e saídas protegidas contra polaridade inversa
D = saídas protegidas contra sobrecorrente e curto-circuito
WS / WE100-2
Distanza di commutazione
(con riflettore PL80A)
Distancia de conmutación
(con reflector PL80A)
开关距离
(带反射器 PL80A)
検出範囲
(リフレクタを用いた場合PL80A)
Расстояние срабатывания
(с отражателем PL80A)
0 ... 20 m
Distanza max. di commutazione
(con riflettore PL80A)
Distancia de conmutación max.
(con reflector PL80A)
最大开关距离
(带反射器 PL80A)
最大検出範囲
(リフレクタを用いた場合PL80A)
Расстояние срабатывания, макс.
(с отражателем PL80A)
0 ... 33 m
Diametro punto luminoso / distanza Diámetro del punto luminoso / distancia
光斑直径 / 距离 光点のスポット径 / 距離 Диаметр светового пятна / расстояние 1,800 mm / 25 m
Tensione di alimentazione U
B
Tensión de alimentación U
B
供电电压 U
B
供給電圧 U
B
Напряжение питания U
B
DC 10 ... 30 V
1)
Corrente di uscita I
max.
Intensidad de salida I
max.
输出电流 I
max.
出力電流 I
max.
Выходной ток I
макс.
100 mA
Sequenza di commutazione max. Secuencia de conmutación max.
最大开关操作顺序 最大スイッチング周波数
Частота срабатывания макс. 1000 Hz
2)
Tempo di reazione max. Tiempo de respuesta max.
最长响应时间 最大応答時間
Время отклика ≤ 0.5 ms
3)
Tipo di protezione Tipo de protección
防护类型 保護等級
Класс защиты IP 67
Classe di protezione Clase de protección
防护等级 保護クラス
Класс защиты
Commutazioni di protezione Circuitos de protección 保护电路 回路保護 Схемы защиты A,B,D
4)
Temperatura ambientale di funzionamento Temperatura ambiente de servicio
工作环境温度 周辺温度 (作動中)
Диапазон рабочих температур -25 ... +55°C
1)
Valori limite:
funzionamento in rete protetta da cortocircuito max. 8 A; ondulazi-
one residua max. ± 10 %
2)
Con rapporto chiaro / scuro 1:1
3)
Durata segnale con carico ohmico
4)
A = U
B
-Allacciamenti protetti dall'inversione di polarità
B = entrate e uscite protette da polarità inversa
D = uscite protette da sovracorrente e da cortocircuito
1)
Valores límite:
funcionamiento en red protegida contra cortocircuitos max. 8 A;
ondulación residual max. ± 10 %
2)
Con una relación claro / oscuro de 1:1
3)
Duración de la señal con carga óhmica
4)
A = U
B
protegidas contra polarización inversa
B = Entradas y salidas protegidas contra polarización incorrecta
D = Salidas a prueba de sobrecorriente y cortocircuitos
1)
极限值:
在防短路电网中运行,最大 8 A;
最大余波 ± 10 %
2)
明暗比为 1:1
3)
信号传输时间(电阻负载时)
4)
A = U
B
接口(已采取反极性保护措施)
B = 具有反极性保护的输入端和输出端
D = 抗过载电流和抗短路输出端
1)
限界値:
短絡保護の操作は最大 8 A;
残留リップルは最大 ± 10 %
2)
ライト / ダークの比率 1:1
3)
負荷のある信号経過時間
4)
A = U
B
接続は逆接保護
B = 入力および出力は逆接保護
D = 出力過電流および短絡保護
1)
Предельные значения:
эксплуатация в защищенной от короткого замыкания сети макс. 8 А;
остаточная волнистость макс. ± 10 %
2)
Соотношение светлых и темных участков изображения 1:1
3)
Продолжительность сигнала при омической нагрузке
4)
A = U
B
-подключения с защитой от перепутывания полюсов
B = входы и выходы с защитой от перепутывания полюсов
D = выходы с защитой от тока перегрузки и короткогозамыкания
+ (L+)
- (M)
not connected
brn
blu
blk
1
3
4
- (M)
Q
brn
blu
blk
1
3
4
+ (L+)
not connected
- (M)
brn
wht
blu
1
2
3
not connected
blk
4
+ (L+)
- (M)
brn
wht
blu
1
2
3
Q
blk
4
+ (L+)
- (M)
brn
blu
- (M)
Q
brn
blu
blk
not connected
blk
A B
E
G
H I
C
More representatives and agencies at www.sick.com ∙ Subject to change
without notice ∙ The specied product features and technical data do not
represent any guarantee.
Weitere Niederlassungen nden Sie unter www.sick.com ∙ Irrtümer
und Änderungen vorbehalten ∙ Angegebene Produkteigenschaften und
technische Daten stellen keine Garantieerklärung dar.
Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à
modication sans préavis ∙ Les caractéristiques de produit et techniques
indiquées ne constituent pas de déclaration de garantie.
Para mais representantes e agências, consulte www.sick.com ∙ Alterações
poderão ser feitas sem prévio aviso ∙ As características do produto e os
dados técnicos apresentados não constituem declaração de garantia.
Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti
soggetti a modiche senza preavviso ∙ Le caratteristiche del prodotto e i
dati tecnici non rappresentano una dichiarazione di garanzia.
Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin
previo aviso ∙ Las características y los datos técnicos especicados no
constituyen ninguna declaración de garantía.
欲了解更多代表机构和代理商信息,请登录 www.sick.com ∙
如有更改, 不另行通知 ∙ 对所给出的产品特性和技术参数
的正确性不予保证。
その他の営業所はwww.sick.com よりご覧ください ・ 予告なしに変更され
ることがあります ・ 記載されている製品機能および技術データは保証を明
示するものではありません。
------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------------------------
BZ int49
Detailed addresses and further locations at www.sick.com
Australia
Phone +61 (3) 9457 0600
1800 33 48 02 –
tollfree
Austria
Phone +43 (0) 2236 62288-0
Belgium/Luxembourg
Phone +32 (0) 2 466 55 66
Brazil
Phone +55 11 3215-4900
Canada
Phone +1 905.771.1444
Czech Republic
Phone +420 234 719 500
Chile
Phone +56 (2) 2274 7430
China
Phone +86 20 2882 3600
Denmark
Phone +45 45 82 64 00
Finland
Phone +358-9-25 15 800
France
Phone +33 1 64 62 35 00
Germany
Phone +49 (0) 2 11 53 010
Greece
Phone +30 210 6825100
Hong Kong
Phone +852 2153 6300
Hungary
Phone +36 1 371 2680
India
Phone +91-22-6119 8900
Israel
Phone +972 97110 11
Italy
Phone +39 02 27 43 41
Japan
Phone +81 3 5309 2112
Malaysia
Phone +603-8080 7425
Mexico
Phone +52 (472) 748 9451
Netherlands
Phone +31 (0) 30 229 25 44
New Zealand
Phone +64 9 415 0459
0800 222 278 – tollfree
Norway
Phone +47 67 81 50 00
Poland
Phone +48 22 539 41 00
Romania
Phone +40 356-17 11 20
Russia
Phone +7 495 283 09 90
Singapore
Phone +65 6744 3732
Slovakia
Phone +421 482 901 201
Slovenia
Phone +386 591 78849
South Africa
Phone +27 10 060 0550
South Korea
Phone +82 2 786 6321/4
Spain
Phone +34 93 480 31 00
Sweden
Phone +46 10 110 10 00
Switzerland
Phone +41 41 619 29 39
Taiwan
Phone +886-2-2375-6288
Thailand
Phone +66 2 645 0009
Turkey
Phone +90 (216) 528 50 00
United Arab Emirates
Phone +971 (0) 4 88 65 878
United Kingdom
Phone +44 (0)17278 31121
USA
Phone +1 800.325.7425
Vietnam
Phone +65 6744 3732
SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch
------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------- 8017528.12HR 0819 COMAT ------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------------------------
2006/42/EG
NO
SAFETY
2006/42/EG
NO
SAFETY