11
EN
Operating Instructions
Use
Position the ozone device in a dry
place that is ventilated well, ideally
high up and approx. 1.5 m above the
oor. It is important to ensure that
nothing prevents the air entering the
fan.
Connect the mains cable supplied to
the mains socket (A4).
The ozone device can now be started
by pressing the on-o button (A3).
The ozone device starts in operating
mode, with full power (100%).
It can take up to about 5 minutes to
achieve the full eect.
Starting the machine
1. Start the ozone device.
Press the switch (A3) to ON
2. Switch o the ozone device
Press the power switch (A3) to OFF
Digital control with timer
(Applicable to Wood’s Airmaster
WOZ3000/6000)
The ozone quantity/output can be
varied between 0 and 100%.
Timer modes: daily, interval and
shut-o timer.
See “Digital control” instructions on
the next page for further information.
Maintenance
NOTE!
Always unplug the device before
carrying out servicing/maintenance.
Replacing the prelter
The prelter has to be replaced every
two to four months, depending on
the ambient environment.
1. Undo the lter holder (A2) by
hand.
2. Replace the lter with a new one.
3. Put back the lter holder (A2).
Cleaning/replacing the ceramic
plate
Ozone is formed when a high-voltage
power supply is passed into the ozone
pipe. The ceramic plate should be
cleaned regularly using methylated
spirit or similar. Wipe down all
surfaces using a dry cloth. Make sure
that all components are fully dry
before restarting the machine. The
ceramic plate must be replaced if
the ozone concentration declines or
ceases entirely.
A. If your ozone device has visible
chassis screws on the long sides
1. Undo all the screws on the long
sides of the chassis.
2. Lift the cover o the machine.
3. Go to point C.
B. If your ozone device has no
visible chassis screws:
1. Undo the two screws that hold the
handle in place.
2. Turn the machine upside down.
3. Undo the four screws that hold the
machine’s feet in place.
4. Remove the chassis cover by
pulling/pushing the cover forwards.
5. Go to point C.
C. Replace the ceramic plate:
1. Undo the quick couplings (F5)
2a. WOZ100 Undo the two screws
holding the ceramic plate in
position (F3)
2b. WOZ3000/6000
Move the ceramic plate (F3) out of
its holder.
3. Assemble in reverse order.
NOTE:
The ceramic plate and prelter are
wear parts and are not covered by the
warranty.
All servicing other than that
described here must be performed
by the manufacturer or an authorised
partner.
Servicing
You must contact your local dealer
if your ozone device requires
maintenance. Receipts must be
presented for all warranty claims.
Storage instructions
Store your ozone device at room
temperature between +1 °C and
+35°C.
USING AND MAINTAINING YOUR OZONE DEVICE
It is important to replace the
prelter at regular intervals and
to replace the ceramic plate
regularly Failing to do this may
impair the capacity of the ozone
device and possibly harm the
device.
USING AND MAINTAINING YOUR OZONE DEVICE