Korenix JetNet 5728G-24P Series Quick Installation Manual

Kategorie
Netzwerk-Switches
Typ
Quick Installation Manual

Dieses Handbuch eignet sich auch für

JetNet 5728G Series
Industrial Managed Ethernet Switch
Quick Installation Guide
www.korenix.com
V1.0
Introduction
JetNet 5728G/5720G series is rackmount High-Port Density and Gigabit Managed Industrial
PoE switch, designed exclusively for highly critical PoE applications such as real time IP
video surveillance with high resolution quality and the evolving wireless communication
systems such as Wimax and 802.11 a/b/g/n Access Points. All of the 8, 16 or 24 Fast
Ethernet PoE injector ports of the switches can deliver 15.4W by IEEE 802.3af or 30W by
the latest High Power PoE IEEE 802.3at standard for upgrading the existing video network
infrastructure to a powerful surveillance network.
The 4 Gigabit Ethernet ports provide high speed uplink to connect with higher level backbone
switches. With the Korenix patented MSRTM network redundancy technology, the switches
can aggregate up to 12 fast Ethernet and 2 gigabit rings while providing high quality data
WUDQVPLVVLRQZLWKOHVVWKDQPVQHWZRUNUHFRYHU\WLPH)XUWKHUPRUHWRHQVXUHWKHWUDI¿F
switching without data loss and blocking, the JetNet 5728G/5720G series provides 12.8G
backplane with the integrated non-blocking switching function. JetNet 5728G/5720G
incorporates LLDP function and perfectly works with the Korenix patented Korenix NMS
for allowing administrators to automatically discover devices and efficiently manage the
industrial network performance in large scale surveillance networks. To further ensure the
non-stop power delivery, JetNet 5728G/5720G series supports dual 53VDC power inputs
and provides alarm relay output signaling function. For high voltage requiring applications the
PoE switch provides extra 100~250VAC power supply capability.
With the advanced Layer2 management features including IGMP Query/Snooping, DHCP,
256 VLAN, QoS, LACP, LPLD, etc. and the corrosion resistant robust design, JetNet
5728G/5720G highly outstands from other PoE switches and becomes the revolutionary
solution for industrial surveillance applications.
Model Name
JetNet 5728G-24P
JetNet 5728G-16P
JetNet 5720G-8P
Description
Rackmount Managed High Power PoE Switch
24 10/100 Base-TX (24 PoE) + 4 Gigabit Combo Ports
Rackmount Managed High Power PoE Switch
24 10/100 Base-TX (16 PoE) + 4 Gigabit Combo Ports
Rackmount Managed High Power PoE Switch
16 10/100 Base-TX (8 PoE) + 4 Gigabit Combo Ports
2. Interface Introduction
2.1 Dimension: JetNet 5728G/5720G Industrial Gigabit Switch dimension (H x W x D)
is 43.8mm x 431mm x 375mm
Diagram: JetNet 5728G
Diagram: JetNet 5720G
8QSDFNWKHER[\RXZLOO¿QG
The Rack Mount Managed Ethernet Switch
RS-232 DB9 (Null-Modem) console cable
Rack Mount kit
Power Cord (Depend on Country
QIG
Hardware Installation
3. Mount the Switch to 19’’ rack
3.1 Attach the brackets to the device by using the screws provided in the Rack Mount kit.
3.2 Mount the device in the 19’ rack by using four rack-mounting screws provided by the
rack manufacturer.
3.3 When installing multiple switches, mount
them in the rack one below the other.
Note: Check if the rack environment
WHPSHUDWXUHFRQIRUPVWRWKHVSHFL¿HG
operating temperature range. Do not
place any equipment on top of the
switch and please properly grounded.
2.2 Panel Layout
The front panel includes up to 24 10/100Mbps Fast Ethernet ports, 4 combo Gigabit
Ethernet ports, SFP slot, RS-232 console port, System / Combo Port LED and up to 24
PoE LED.
The back panel of the JetNet 5728G Industrial Gigabit Managed Switch consists of two
DC power inputs, 1 AC Input, 1 Relay Output.
1357
2468
91 11 31 5
10 12 14 16
17 19 21 23
18 20 22 24
G1(25) G3(27) G1(25) G3(27)
G2(26) G4(28) G2(26) G4(28)
Console
G3G113 59 11 15 17 19 21 2371 3
24 68 10 12 14 16 18 20 22 24
Alarm
DC1
DC2
PSU
R.S.
Sys
LNK
ACT
LNK
ACT
JetNet 5728G
24+4G Rackmount Gigabit
Managed PoE Plus Ethernet Switch
G4G2
af/at
af/at
4. Power the unit and connect to network Cable
4.1 Wiring Power Inputs
JetNet 5728G/5720G provides 2 types power input, AC power input and DC power input.
It also provides redundant or aggregated power inputs, depending on the voltage of
power input. If there are over 2 power inputs are connected with different voltages, JetNet
5728G/5720G will be powered from the highest connected voltage (redundant power).
If the voltages of power inputs are the same, the total power output will be aggregated
(aggregated power).
AC Power Input
Connect the attached power cord to the AC power input connector, the available AC power
input is range from 100-250VAC.
High Voltage Power Input
The power input support both 100-250VAC power input. Connect the power cord to the
PE for Protective Earth, L / V+ for LINE or V+, N/V- for Neutral or V-. For high power input,
tighten the wire-clamp screws to prevent DC wires from being loosened is must.
DC Power Inputs
The range of the available DC power input is from 46-57VDC. In the IEEE802.3at mode,
the PoE power output is 50~57 VDC, 0.6A, therefore, the suggested DC power input
ranges is 53VDC (52~57VDC). In the IEEE802.3af mode, the PoE power output is 44~57
VDC, 0.35A, therefore, the suggested DC power input is 48VDC (46~57VDC).
If the DC power input is 53VDC, the unit will aggregate the power with the AC power input,
if any.
Follow below steps to wire JetNet 5728G/5720G redundant or aggregated DC power
inputs.
1. Insert positive and negative wires into V+ and V- contacts
respectively of the terminal block connector.
2. Tighten the wire-clamp screws to prevent DC wires from
being loosened.
3. DC1 and DC2 support polarity reverse protection functions.
Note 1: It is a good practice to turn off input and load power.. Otherwise, your screwdriver
blade can inadvertently short your terminal connections to the grounded enclosure.
Note 2: The range of the suitable electric wire is from 12 to 22 AWG.
Note 3: The unit will alarm for loss of power, for instance, PSU, DC1 or DC2.
Power Supply
Type
Input Range
Max. Input
Current
Fuse
Rating
Max. Power
Consumption
Mix Max All Ethernet Ports
48 VDC
53 VDC
46 VDC 57 VDC 8.2 A 10 A (T)
30W
HI (110/230
VAC), 47-63Hz
100 VAC 252 VAC 4 A 4 A (T)
Power Supply
Type
Input Range
Fuse
Rating
Power Consumption
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 369.6W 369.6W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 568W 720W
3RZHU6XSSO\6SHFL¿FDWLRQV
7DEOH3RZHU6XSSO\6SHFL¿FDWLRQV
JetNet 5728G-24P
Power Supply
Type
Input Range
Fuse
Rating
Power Consumption
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 246.4W 246.4W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 364W 480W
JetNet 5728G-16P
Power Supply
Type
Input Range
Fuse
Rating
Power Consumption
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 123.2W 123.2W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 182W 240W
JetNet 5720G-8P
7DEOH3R(3R(3OXV3RZHU6XSSO\6SHFL¿FDWLRQV
Note 1: (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
Note 2: Power consumption varies based on configuration. 10/100Tx ports consume
URXJKO\:OHVVWKDQ¿EHURSWLFSRUWV
1RWH)RUFRQWLQXHGSURWHFWLRQDJDLQVWULVNRI¿UHUHSODFHRQO\ZLWKVDPHW\SHDQG
rating of fuse.
4.3 Wiring Digital Output
JetNet 5728G/5720G provides 1 digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close for fault conditions. The
IDXOWFRQGLWLRQVLQFOXGHSRZHUIDLOXUH(WKHUQHWSRUWOLQNEUHDNRURWKHUSUHGH¿QHGHYHQWV
ZKLFKFDQEHFRQ¿JXUHGLQ-HW1HW**8,
Wiring digital output is exactly the same as wiring power input introduced in chapter 2.2.
4.4 Wiring Earth Ground
To ensure the system will not be damaged by noise or any electrical shock, we suggest
you to make exact connection with JetNet 5728G/5720G with Earth Ground.
On the back panel of JetNet 5728G/5720G, there is one earth ground screw. Loosen
the earth ground screw by screw drive; then tighten the screw after earth ground wire is
connected.
4.5 Wiring Fast Ethernet Ports
JetNet 5728G/5720G includes 24 RJ-45 Fast Ethernet ports. The fast Ethernet ports
support 10Base-T and 100Base-TX, full or half duplex modes. All the fast Ethernet ports
will auto-detect the signal from connected devices to negotiate the link speed and duplex
mode. Auto MDI/MDIX allows users to connect another switch, hub or workstation without
changing straight through or crossover cables.
Note that crossover cables simply cross-connect the transmit lines at each end to the
received lines at the opposite end.
Straight-through Cabling Schematic Cross-over Cabling Schematic
Connect one side of an Ethernet cable into any switch port and connect the other side to
your attached device. The LNK LED will light up when the cable is correctly connected.
Refer to the LED Indicators section for descriptions of each LED indicator. Always make
sure that the cables between the switches and attached devices (e.g. switch, hub, or
workstation) are less than 100 meters (328 feet).
The wiring cable types are as below.
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable, EIA/TIA-568 100-ohm (100m)
100 Base-TX: 2-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m)
1000 Base-TX: 4-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m)
IEEE 802.3af : 4-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m)
IEEE 802.3at : 4-pair UTP/STP Cat. 5e / 6 cable, EIA/TIA-568 100-ohm (100m)
Note that Ethernet cables use pins 1, 2,
3, and 6 of an 8-pin RJ-45 connector.
The signals of these pins are converted
by the automatic MDI-X function, as
shown in the table below:
Pin MDI-X
1
2
3
6
Signals
RD+
RD-
TD+
TD-
MDI Signals
TD+
TD-
RD+
RD-
4.6 Wiring Combo Ports
JetNet 5728G/5720G includes 4 RJ-45 Gigabit Ethernet ports. The speed of the gigabit
Ethernet port supports 10Base-T, 100Base-TX and 1000Base-TX. JetNet 5728G/5720G
also equips 4 gigabit SFP ports combo with gigabit Ethernet ports. The speed of the
SFP port supports 1000Base-SX/LX. The SFP ports accept standard MINI GBIC SFP
transceiver. But, to ensure system reliability, Korenix recommends using the Korenix
FHUWL¿FDWHG*LJDELW6)37UDQVFHLYHU7KHFHUWL¿FDWHG6)3WUDQVFHLYHULQFOXGHV%DVH
SX/LX single/multi mode ranger from 550m to 80KM.
4.7 Data and Power Ports
JetNet 5728G/5720G comes standard with up to 24 10/100BaseTX IEEE802.3af (PoE)
and IEEE802.3at (PoE Plus) compliant Ethernet ports (ports 1-24). In addition to the
10/100BaseTX port features, the PoE ports provide normal 48 VDC at 350mA (max
15.4W/port) or provide normal 53 VDC at 606mA (max 30W/port), auto-sensing and
automatic power off when cables are removed. The following table shows the RJ45 PoE
pin-out assignment.
10/100BaseTx PoE Pin-out
Pin Description
1 RX + and Vport -
2 RX – and Vport -
3 TX + and Vport +
6 TX – and Vport +
4, 5, 7, 8 NC
Table: RJ45 PoE pin-out assignment
This product is designed for in building installation only and is not intended to be
connected to exposed (outside plant) networks.
4.8 Wiring RS-232 Console Cable
Korenix JetNet 5728G/5720G attaches one RS-232 DB-9 to DB-9 cable in the box.
Connect the DB-9 connector to the COM port of your PC, open Terminal tool and set up
serial settings to 9600, N,8,1. (Baud Rate: 9600 / Parity: None / Data Bit: 8 / Stop Bit: 1)
Then you can access CLI interface by console cable.
Note: If you lost the cable, please contact with your sales or follow the pin assignment to
buy a new one. The Pin assignment spec is listed in the appendix.
1.1 Go to Start -> Program -> Accessories -> Communication -> Hyper Terminal
1.2 Give a name to the new console connection.
1.3 Choose the COM name, and select the correct serial settings. The serial settings of
the JetNet 5728G/5720G are as below:
Baud Rate: 9600 / Parity: None / Data Bit: 8 / Stop Bit: 1
1.4 After connected, you can see Switch login request. Type the username and password
then you can login. The default username is “admin”, password is “admin”.
)ROORZWKHPDQXDOWRFRQ¿JXUHWKHVRIWZDUHIHDWXUHV
Note: The Hyper Terminal may need to be additionally installed in the Windows 7, 8, and
Vista.
Device Management
JetNet 5728G/5720G Rack Mount Managed Ethernet Switch provides both in-band and
RXWEDQGFRQ¿JXUDWLRQPHWKRGV<RXFDQFRQ¿JXUHWKHVZLWFKYLDWKH56FRQVROHZLWK
WKHDWWDFKHGFRQVROHFDEOH2U\RXFDQUHPRWHO\PDQDJHWKHVZLWFKYLDQHWZRUN<RXFDQ
choose Telnet/SSH, Web/HTTPS management.
1. Preparation for console management: Attach the RS-232 DB9 connector to your
PC’s COM port. Connect the RS-232 DB9 connector to the console port of the JetNet
5728G/5720G.
2. Preparation for Web management: Before you attempt to use the embedded web interface
to manage switch operation, verify that your JetNet 5728G/5720G is properly installed on
your network and that every PC on this network can access the switch via the web browser.
2.1 Launch the web browser (Internet Explorer or
Mozila Firefox) on the PC.
2.2 Type http://JetNet 5728G/5720G_IP_Address
(The default IP address is 192.168.10.1.)
then press Enter.
2.3 he login screen will appear next. Key in the user
name and the password. The default user name and
password is admin/admin.
2.4 Click OK, and then the Home page of the
web-based management interface will appear.
2.5 At the left column of the web management
interface is the software function. The right
column lists the available settings. The top
column indicates the front panel and shows
the link status of each interface.
Korenix Customer Service
KoreCARE is Korenix Technology’s global service center, where our professional staffs are
ready to answer your questions at any time.
Email address of Korenix Global Service Center: [email protected]
3. Preparation for Telnet management: Go to Start -> Program -> Accessories -> DOS
Prompt, Type Telnet 192.168.10.1 (Default IP Address) then press Enter.
㥩志
JetNet 5728G/5720G㌱ࡍᵰᷬᕅཐㄥਙθॹݼ㖇㇗ශᐛѐPoEӚᦘᵰщѰ儎ḽ߼儎㾷≸Ⲻ
PoEᓊ⭞㙂䇴䇗θׁྸᇔᰬⲺIP㿼仇ⴇ᧝㌱㔕θՐ⎿਀䈮ྸWimax802.11a/b/g/nㅿݾ䘑Ⲻ
儎ࣕ⦽儎ᑜᇳⲺᰖ㓵䇴༽᧛ޛȾӚᦘᵰⲺ8Ѡθ16Ѡᡌ24ѠPoEԛའ㖇ב⭫ㄥਙൽ᭥ᤷIEEE
802.3afIEEE 802.3atњ〃ב⭫ḽ߼θᨆב15.4W30W⭫䠅䗉࠰θਥሼ⧦ᴿⲺ㿼仇㖇㔒ॽ
㓝ѰᴪᕰཝⲺ㿼仇ⴇ᧝㖇Ⱦ
4Ѡॹݼԛའ㖇ਙᨆב儎䙕р䘔䙐䚉θਥ䘔᧛рቸѱᒨӚᦘᵰȾ䟽⭞Korenixщ࡟MSRTM㖇㔒
ߍ֏ᢶᵥθӚᦘᵰਥ᮪ਾ12ѠⲴݼ⧥㖇ૂ2Ѡॹݼ⧥㖇θᨆב儎૷䍞ⲺᮦᦤՖ䗉ᵃࣗθ㠠᜾
ᰬ䰪ቅӄ5msȾ↚ཌθѰҼ⺤ؓᮦᦤӚᦘ䗽ぁ⋗ᴿԱ֋јऻᡌᤛ๫⧦䊗θ5728G/5720Gᨆב
12.8G㜂ᶵᒬ᮪ਾҼᰖ䱱ດӚᦘࣕ㜳ȾJetNet 5728G/5720G᭥ᤷLLDP䬴䐥ቸਇ⧦অ䇤θ㜳ཕ
ᇂ㗄ⲺфKorenixщ࡟JetView Pro i2NMS㖇㇗䖥Ԭާੂ֒⭞θᑤࣟ⭞ᡭ൞ཝශ㿼仇ⴇ᧝㖇㔒ѣ
㠠ࣞỶ㍘䇴༽θᒬᴿ᭾Ⲻ㇗⨼൞㓵䇴༽ȾѰҼ⺤ؓу䰪ᯣⲺ⭫ⓆבᓊθJetNet 5728G/5720G
᭥ᤷ53VDCਂ⭫Ⓠ䗉ޛԛ਀ᯣ⭫㔝⭫ಞᣛ䆜䗉࠰ࣕ㜳Ⱦ䪾ሯ儎ু⭫Ⓠ⧥ູⲺᓊ⭞θPoEӚᦘ
ᵰ⢯ࡡᨆב100~250VAC儎ুᵰශਥב䘿᤟Ⱦ
ݾ䘑Ⲻ2ቸ㖇㇗ࣕ㜳ऻᤢIGMP Query/SnoopingθDHCPθ256ѠVLAN㓺θQoSθLACPθ
LPLDㅿㅿȾ JetNet 5728G/5720G䟽⭞ᕰരⲺᣍ㞆㲶ᶆᯏ䇴䇗θ䖹ެᆹPoEӚᦘᵰどᇐᙝᴪ
儎θᱥᐛѐ㿼仇ⴇ᧝㖇㔒Ⲻ䶟ળᙝ䀙ߩᯯṾȾ
1. ᢉᔶऻ㻻Ỷḛ䞃Ԭ
ᵰᷬᕅ㖇㇗ශӚᦘᵰ
RS-232 DB9 (Null-Modem)᧝࡬㓵㔼
ᵰᷬᆿ㻻䞃Ԭ
⭫Ⓠ㓵(דᦤуੂളᇬ㿺㤹)
QIGᘡ䙕ᆿ㻻ੇሲ
䡓ờ⭰墬
CH
2. ⮂䶘ԁ㔃
2.1 ተሮ: JetNet 5728G/5720GॹݼᐛѐӚᦘᵰተሮ(H x W x D)Ѱ
43.8mm x 431mm x 375mm
Diagram: JetNet 5728G
Diagram: JetNet 5720G
3. ሼӚᦘᵰ㻻р19㤧ሮᵰᷬ
3.1 ⭞㷰ѓሼᢎᷬരᇐ൞Ӛᦘᵰњם
3.2 4仍ᵰᷬ㷰ѓሼӚᦘᵰ㻻р19㤧ሮᵰᷬ
3.3 䴶㾷ᆿ㻻ཐਦӚᦘᵰᰬθԄрᖶсжቸቸരᇐ
4. Ѱ䇴༽ב⭫θ䘔᧛㖇㓵
༽⌞: Ỷḛᵰᷬ޻⧥ູ⑟ᓜᱥੜ൞㿺Ṳ
㤹പ޻θу㾷᭴㖤Ա֋⢟૷൞Ӛᦘᵰ京
䜞θ䈭↙⺤᧛൦Ⱦ
2.2 䶘ᶵᐹቶ
ࢃ䶘ᶵऻᤢᴶཐ24Ѡ10/100Mbpsᘡ䙕ԛའ㖇ਙθ4Ѡcomboॹݼԛའ㖇ਙθSFPᨈ″θRS-
232᧝࡬ㄥਙθ㌱㔕/Comboਙ⣬ᘷ᤽⽰⚥Ⱦ
JetNet 5728G੄䶘ᶵऻ੡2DC⴪⍷⭫䗉ޛㄥᆆθ1ACӚ⍷⭫ᨈᆊθ1䐥㔝⭫ಞᣛ䆜䗉࠰
1357
2468
91 11 31 5
10 12 14 16
17 19 21 23
18 20 22 24
G1(25) G3(27) G1(25) G3(27)
G2(26) G4(28) G2(26) G4(28)
Console
G3G113 59 11 15 17 19 21 2371 3
24 68 10 12 14 16 18 20 22 24
Alarm
DC1
DC2
PSU
R.S.
Sys
LNK
ACT
LNK
ACT
JetNet 5728G
24+4G Rackmount Gigabit
Managed PoE Plus Ethernet Switch
G4G2
af/at
af/at
4.1 䘔᧛⭫Ⓠ㓵
JetNet 5728G/5720Gᨆב2〃⭫Ⓠ䗉ޛθACӚ⍷⭫ૂDC⴪⍷⭫Ⓠθੂᰬҕ᭥ᤷߍ֏⭫ⓆȾ
ྸ᷒2䐥⭫ⓆⲺ⭫ুуж㠪θJetNet 5728G/5720GՐֵ⭞⭫ু儎㘻ב⭫(ߍ֏⭫Ⓠ)Ⱦ㤛2
䗉ޛ⭫ুж㠪θࡏ᮪ᵰ䗉࠰ࣕ⦽Ր㻡᮪ਾȾ
AC⭫Ⓠ䗉ޛ
ሼḽ䞃⭫Ⓠ㓵᧛ޛAC⭫Ⓠ᧛ਙθᴿ᭾ⲺAC⭫Ⓠ䗉ޛ㤹പᱥφ100-250VAC.
儎ু⭫Ⓠ䗉ޛ
DC⭫Ⓠ䗉ޛ
DC⴪⍷⭫䗉ޛ㤹പᱥφ46-57VDCȾ൞IEEE802.3at⁗ᕅθPoE䗉ޛѰ50~57 VDCθ0.6Aθ
ഖ↚ᔰ䇤ֵ⭞53VDC (52~57VDC)⭫Ⓠב⭫Ⱦ൞IEEE802.3af⁗ᕅθPoE䗉࠰Ѱ44~57
VDCθ0.35Aθഖ↚ᔰ䇤ֵ⭞48VDC (46~57VDC)⭫Ⓠב⭫Ⱦ㤛DC⭫ⓆѰ53VDCθъੂᰬ
ᴿAC⭫Ⓠב⭫θࡏӚᦘᵰՐሼ䗉࠰⭫䠅᮪ਾȾ
䈭דᦤྸс↛僚ѰJetNet 5728G/5720G䘔᧛ߍ֏ᡌ㚐ਾDC⭫Ⓠ
1. ሼ⭫ⓆⲺ↙䍕ᶷ࠼ࡡᨈޛ᧛㓵ㄥᆆⲺV+ V- ᨈ″
2. ᤝ㍝㓵཯㷰ѓθ䱨↘DC⭫Ⓠ㓵㝧㩳
3. DC1 DC2᭥ᤷᶷᙝਃ᧛ؓᣚ
༽⌞1: ൞䘔㓵ҁࢃθ䈭ީ䰣⭫Ⓠθᒬሼ᧛㓵ㄥᆆᤊсȾੜࡏθᛞⲺ㷰ѓ࠶ਥ㜳䙖ᡆ᧛㓵ㄥ
ᆆф൦㓵⸣䐥Ⱦ
༽⌞2: 䘸⭞⭫Ⓠ㓵㤹പ12Њ22 AWG
༽⌞3: ⭫ⓆѣᯣӚᦘᵰਥԛਇ࠰ᣛ䆜θׁྸθPSUθDC1DC2
Table: ⭫Ⓠ㿺Ṳ
4.2 ⭫Ⓠ㿺Ṳ
⭫Ⓠ㊱ශ
䗉ޛ㤹പ
ᴶཝ䗉ޛ
⭫⍷
ؓ䲟ѓ
ㅿ㓝
ᴶཝࣕ㙍
Mix Max
ᡶᴿԛའ㖇ਙ
48 VDC
53 VDC
46 VDC 57 VDC 8.2 A 10 A (T)
30W
HI (110/230
VAC), 47-63Hz
100 VAC 252 VAC 4 A 4 A (T)
JetNet 5728G-24P
⭫Ⓠ㊱ශ
䗉ޛ㤹പ
ؓ䲟ѓ
ㅿ㓝
ࣕ㙍
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 369.6W 369.6W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 568W 720W
⭫Ⓠ㊱ශ
䗉ޛ㤹പ
ؓ䲟ѓ
ㅿ㓝
ࣕ㙍
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 246.4W 246.4W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 364W 480W
JetNet 5728G-16P
Table: PoE/PoE + ⭫Ⓠ㿺Ṳ
༽⌞1: (F)㺞⽰ᘡ⟊ؓ䲟ѓ, (T)㺞⽰ᰬᔬؓ䲟ѓ
༽⌞2: ࣕ㙍਎ौะӄ㔉ᶺ਎ौȾ10/100TxㄥਙⲺࣕ㙍㓜Ѱ1Wθ∊ݿਙքȾ
༽⌞3: ѰҼ䱨↘⚡⚴ধ䲟θ䈭ᴪᦘੂ㊱ශੂㅿ㓝Ⲻؓ䲟ѓ
4.3 䘔᧛DO
JetNet 5728G/5720Gᨆבж䐥DOθᡌ〦Ѱ㔝⭫ಞᣛ䆜䗉࠰Ⱦ↙ᑮ⣬ᘷс㔝⭫ಞ䀜⛯ᱥᔶ䐥
⣬ᘷθᖉ࠰⧦᭻䳒ᰬθࡏ䰣ਾȾ᭻䳒ӁԬऻᤢφ⭫Ⓠѣᯣθ㖇ਙѣᯣᡌެԌ人䇴ӁԬȾ
DO᧛㓵ф2.2ㄖ㢸ѣⲺ⭫Ⓠ᧛㓵ᇂޞжṭ
⭫Ⓠ㊱ශ
䗉ޛ㤹പ
ؓ䲟ѓ
ㅿ㓝
ࣕ㙍
Mix Max Worst Case Max
48VDC
(IEEE802.3af)
46 VDC 57 VDC 1.5 A (F) 123.2W 123.2W
53 VDC
(IEEE802.3at)
52 VDC 57 VDC 1.5 A (F) 182W 240W
JetNet 5720G-8P
4.4 ᧛൦
ѰҼ⺤ؓ㌱㔕у਍ಠ༦ᡌ⭫࠱ᖧଃθᔰ䇤ሼJetNet 5728G/5720G↙⺤᧛൦Ⱦ
JetNet 5728G/5720GⲺ੄䶘ᶵᴿжѠ൦㓵㷰∃θᶴᔶ᧛൦㷰ѓθ᧛ޛ᧛൦㓵θᤝ㍝㷰ѓ䱨
↘㝧㩳Ⱦ
4.5 䘔᧛ᘡ䙕ԛའ㖇ㄥਙ
JetNet 5728G/5720Gऻ੡24ѠRJ-45ᘡ䙕ԛའ㖇ਙȾᘡ䙕ԛའ㖇ㄥਙ᭥ᤷ10Base-Tθ
100Base-TXθޞਂᐛঀਂᐛ⁗ᕅȾᡶᴿㄥਙ᭥ᤷ㠠ࣞঅ୼θ㠠䘸ᓊਂᐛ⁗ᕅȾ㠠䘸ᓊ
MDI/MDIXࣕ㜳θᯯ׵⭞ᡭ䘔᧛ެԌӚᦘᵰθ䳼㓵ಞᡌᐛ֒ㄏθᰖ䴶ᴪᦘӚ৿ᡌ⴪䙐㓵
㔼Ⱦ
⴪䙐㓵ഴ⽰ Ӛ৿㓵ഴ⽰
ԛའ㖇㓵ⲺжㄥᨈޛӚᦘᵰㄥਙθਜжㄥ䘔᧛ᛞⲺ⧦൰䇴༽Ⱦ㤛᧛㓵↙⺤θLink᤽⽰⚥ՐӤ
䎭Ⱦ৸䰻LED᤽⽰⚥ᨅ䘦Ҽ䀙∅ѠLED⣬ᘷȾ⺤ؓӚᦘᵰૂ䇴༽ҁ䰪(ׁྸӚᦘᵰθ䳼㓵ಞ
ᡌᐛ֒ㄏ)Ⲻ䘔㓵у䎻䗽100(328㤧ተ)Ⱦ
㓵㔼㿺Ṳྸсφ
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable, EIA/TIA-568 100-ohm (100m)
100 Base-TX: 2-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m)
1000 Base-TX: 4-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m)
IEEE 802.3af : 4-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100
m)
IEEE 802.3at : 4-pair UTP/STP Cat. 5e / 6 cable, EIA/TIA-568 100-ohm (100m)
⌞ᝅԛའ㖇㓵ֵ⭞Pins 1θ2θ3θ6Ֆ
䗉ᮦᦤȾ䘏ӑؗਭᕋ㝐㠠䘸ᓊMDI-X θ
ྸഴ㺞ᡶ⽰φ
Pin MDI-X
1
2
3
6
Signals
RD+
RD-
TD+
TD-
MDI Signals
TD+
TD-
RD+
RD-
4.6 䘔᧛Comboㄥਙ
JetNet 5728G/5720Gऻ੡4ѠRJ-45ॹݼԛའ㖇ਙθㄥਙ䙕⦽᭥ᤷ10Base-Tθ100Base-
TXθ1000Base-TX ȾJetNet 5728G/5720G䞃༽4ѠॹݼSFP/RJ-45 ComboㄥਙȾSFP᭥ᤷ
1000Base-SX/LXȾSFPㄥਙ᧛਍ḽ߼MINI GBIC SFP᭬ਇಞȾѰҼ⺤ؓ㌱㔕ਥ䶖ᙝθ᧞㦆
ֵ⭞㔅䗽Korenix僂䇷ⲺSFPݿ᭬ਇಞ⁗ඍȾ䙐䗽䇚䇷ⲺSFP᭬ਇಞ⁗ඍऻᤢ1000Base-SX/
LX ঋ⁗/ཐ⁗θ550MЊ80KMуੂ㿺ṲȾ
4.7 ᮦᦤૂ⭫Ⓠㄥਙ
JetNet 5728G/5720Gᤛᴿᴶཐ24Ѡ10/100BaseTX IEEE802.3af (PoE)IEEE802.3at (PoE
Plus) ㄥਙȾ䲚Ҽ10/100BaseTXㄥਙ⢯ᙝθPoEㄥਙᨆב48 VDC@350mA (ᴶ儎15.
4W/
port)⭫䠅䗉࠰θᡌ53 VDC@606mA (ᴶ儎30W/port)θᖉ㖇㓵ѣᯣᰬՐ㠠ࣞỶ⎁ᒬ㠠ࣞᯣ
⭫Ⱦс㺞ࡍ࠰ҼRJ45 PoEㄥਙⲺpin-outᇐѿ
10/100BaseTx PoE Pin-out
Pin Description
1 RX + and Vport -
2 RX – and Vport -
3 TX + and Vport +
6 TX – and Vport +
4, 5, 7, 8 NC
Table: RJ45 PoE pin-out assignment
䈛ӝ૷䇴䇗Ѱᇚ޻ᆿ㻻θу᧞㦆⭞ӄᡭཌ㖇㔒⧥ູȾ
4.8 䘔᧛RS-232᧝࡬ㄥਙ
Korenix JetNet 5728G/5720Gḽ䞃жᶗRS-232 DB-9DB-9᧝࡬㓵㔼ȾሼDB9᧛ཪ䘔᧛ࡦ
PCCOMਙθᢉᔶ㌱㔕䎻㓝㓾ㄥθ䇴ᇐѨਙ৸ᮦ9600, N,8,1. (Baud Rate: 9600 / Parity:
None / Data Bit: 8 / Stop Bit: 1)θࡏਥ䙐䗽CLIળԚ㺂䇵䰤ӚᦘᵰȾ
༽⌞φ㤛ሼ㓵㔼䚍ཧθ䈭㚊㌱䬶୤ネਙҼ䀙Pin㝐ᇐѿ䠃᯦ཕҦȾPin㝐ᇐѿՐ൞䱺ᖋѣࡍ
᱄Ⱦ
䇴༽㇗⨼
JetNet 5728G/5720Gᵰᷬᕅ㖇㇗ශᐛѐԛའ㖇Ӛᦘᵰ᭥ᤷᑜ޻(in-band)਀ᑜཌ(out-band)䇴㖤
⁗ᕅȾ⭞ᡭਥԛ䙐䗽RS232᧝࡬ㄥਙሯӚᦘᵰ䘑㺂䇴㖤θᡌ䙐䗽㖇
㔒䘑㺂䘒ぁ㇗⨼Ⱦᛞ䘎ਥԛ
䘿᤟Telnet/SSH, Web/HTTPSཐ〃㇗⨼⮂䶘Ⱦ
1. Console㇗⨼Ⲻ߼༽ᐛ֒: RS-232 DB9᧛ཪㄥ䘔᧛ࡦ֖䇗㇍ᵰⲺCOMਙθሼRJ-45ㄥਙᨈ
ޛJetNet 5728G/5720GⲺ᧝࡬ㄥਙȾ
1.1 䘆㺂Start(੥ࣞ) -> Program(ぁᓅ) -> Accessories(䱺Ԭ) -> Communication(䙐䇥) ->
Hyper Terminal(䎻㓝㓾ㄥ)
1.2 Ѱ᧝࡬䘔㓵ળ੃Ⱦ
1.3 䘿᤟COMㄥਙਭθ䇴ᇐ↙⺤ⲺѨਙ৸ᮦȾJetNet 5728G/5720GⲺѨਙ৸ᮦྸсφ
Baud Rate: 9600 / Parity: None / Data Bit: 8 / Stop Bit: 1
1.4 䘔᧛੄θՐ࠰⧦ӚᦘᵰⲺⲱᖋᨆ⽰Ⱦ䭤ޛ⭞ᡭ੃਀ᇼ⸷঩ਥⲱᖋȾ唎䇚⭞ᡭ੃ᱥ
"admin"θᇼ⸷ᱥ"admin"Ⱦ
1.5 ṯᦤ⭞ᡭᢁ߂䘑㺂ࣕ㜳䇴㖤Ⱦ
2. Web㇗⨼߼༽ᐛ֒: ൞ֵ⭞޻㖤Web⮂䶘ሯӚᦘᵰᇔ᯳㇗⨼ҁࢃθ䈭ݾ僂䇷JetNet
5728G/5720Gᐨ㔅↙⺤᧛ޛ㖇㔒θъ㖇㔒ѣⲺԱᝅ䇗㇍ᵰ䜳ਥԛ䙐䗽Web⎅㿾ಞ䇵䰤Ӛᦘ
ᵰȾ
2.1 ੥ࣞ䇗㇍ᵰрⲺ⎅㿾ಞ (IE
㿾ಞᡌMozila Firefox)
2.2 ൞൦൶ṅ䭤ޛhttp://JetNet 5728G/5720G_IP_
Address (唎䇚IP൦൶Ѱ 192.168.10.1.) ❬੄ഔ䖜
2.3 ࠰⧦ⲱᖋネਙθ䭤ޛ⭞ᡭ੃ૂᇼ⸷θ唎䇚Ⲻ⭞ᡭ੃
ૂᇼ⸷ᱥadmin/admin
2.4 ⛯࠱"OK"䭤θࡏՐ࠰⧦web㇗⨼⮂䶘Ⲻѱ享
2.5 ൞享䶘ⲺᐜםᱥӚᦘᵰ਺亯ࣕ㜳ሯᓊⲺળԚ
ṇȾ਩םࡏՐᱴ⽰ᖉࢃ䇴ᇐȾ京䜞Ѱࢃ䶘ᶵഴ
⽰θᱴ⽰਺ѠㄥਙⲺ䘔㓵⣬ᘷ
Korenix ᇘᡭᵃࣗ
KoreCAREᱥ〇⍑⨼ᙓ〇ᢶޞ⨹ᵃࣗѣᗹθᡇԢщѐⲺᢶᵥӰ઎䳅ᰬ߼༽䀙ㆊᛞⲺ⯇䰤Ⱦ
〇⍑⨼ᙓޞ⨹ᇘᵃѣᗹEmail൦൶Ѱ: [email protected]
3. Telnet㇗⨼Ⲻ߼༽ᐛ֒: 䘆㺂Start(੥ࣞ) -> Program(ぁᓅ) -> Accessories(䱺Ԭ) -> DOS(
Ԛ㺂)θ䭤ޛTelnet 192.168.10.1 (Ӛᦘᵰ唎䇚IP൦൶) ❬੄ഔ䖜Ⱦ
Einführung
Die JetNet 5728G/5720G Serie sind 19” Rack-Montage Gigabit administrierbare industrielle
PoE Switches mit hoher Portdichte, entwickelt insbesondere für hochkritische PoE
Anwendungen wie Echtzeit IP Video Überwachung mit hoher Auflösungsqualität oder für
neue Systeme der drahtlosen Kommunikation wie z.B. WiMAX und 802.11 a/b/g/n Access
Points. Jeder der 8, 16 oder 24 Fast Ethernet PoE Injektor Ports der Switches liefert
15.4W gemäß IEEE 802.3af oder 30W gemäß des letzten High-Power PoE IEEE 802.3at
Standard zur Modernisierung zur Aufrüstung existierender Video Netzwerkinfrastukturen zu
leistungsstarken Videoüberwachungsnetzwerken.
Die 4 Gigabit Ethernet Ports bieten einen High Speed Uplink für die Verbindungen zu
darüber liegenden Backbone Switches. Mit der Korenix patentierten MSRTM Netzwerk
Redundanz Technologie können die Switches bis zu 12 Fast Ethernet und 2 Gigabit Rings
aggregieren und dies bei höchster Datenübertragungsqualität mit weniger als 5ms Netzwerk
Recovery Time. Weiterhin, um ein Data-Switching ohne Datenverlust oder Blockierung zu
gewährleisten, bietet die JetNet 5728G/5720G Serie eine 12.8G Backplane mit integrierter
Non-Blocking Switching Funktion. Die in den JetNet 5728G/5720G eingebaute LLDP Funktion
arbeitet perfekt mit der von Korenix patentierten Korenix Network Management Software
NMS zusammen und erlaubt damit Administratoren eine automatische Erkennung der
*HUlWHXQGHLQHHI¿]LHQWH$GPLQLVWUDWLRQGHU1HW]ZHUN3HUIRUPDQFHLQJURHQLQGXVWULHOOHQ
Überwachungsnetzwerken. Um zusätzlich eine Non-Stop Stromversorgung sicherzustellen,
unterstützt die JetNet 5728G/5720G Serie redundante 53VDC Power Eingänge und bietet
Alarmrelais Ausgänge als Signalfunktion. Für Anwendungen mit Stromnetzspannung bieten
die PoE Switches einen eigenen 100~250VAC Stromversorgungseingang.
DE
Model Name
JetNet 5728G-24P
JetNet 5728G-16P
JetNet 5720G-8P
Description
Administrierbarer Rackmount High Power PoE Switch mit
24 10/100 Base-TX (24 PoE) + 4 Gigabit Combo Ports
Administrierbarer Rackmount High Power PoE Switch mit
16 10/100 Base-TX (16 PoE) + 4 Gigabit Combo Ports
Administrierbarer Rackmount High Power PoE Switch mit
16 10/100 Base-TX (8 PoE) + 4 Gigabit Combo Ports
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Korenix JetNet 5728G-24P Series Quick Installation Manual

Kategorie
Netzwerk-Switches
Typ
Quick Installation Manual
Dieses Handbuch eignet sich auch für