hivolt HAR2 Bedienungsanleitung

Kategorie
Audioverstärker
Typ
Bedienungsanleitung
1
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
HAR12
12 Channel
High Voltage Amplifier
HAR2
2 Channel
High Voltage Amplifier
Operating Manual
2
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
1 WARNINGS ................................................................................................................................................................ 3
2 OVERVIEW................................................................................................................................................................ 5
3 DESCRIPTION........................................................................................................................................................... 5
3.1 BLOCK DIAGRAM ................................................................................................................................................... 6
3.2 CONTROL VOLTAGE INPUT ................................................................................................................................... 7
3.3 MEASURING CIRCUITS / MONITOR OUTPUTS .................................................................................................... 7
3.4 INHIBIT............................................................................................................................................................... 8
3.5 LOADING CONDITIONS......................................................................................................................................... 8
4 INSTALLATION AND OPERATION ..................................................................................................................... 9
4.1 GENERAL................................................................................................................................................................ 9
4.2 TEMPERATURE BALANCE ....................................................................................................................................... 9
4.3 FUNCTIONAL TEST ................................................................................................................................................ 9
4.4 OUTPUT CONNECTIONS ........................................................................................................................................ 9
4.5 VENTILATION REQUIREMENTS ............................................................................................................................. 9
4.6 RACK MOUNTING HAR12 ................................................................................................................................10
4.7 WALL MOUNTING HAR2-W............................................................................................................................. 10
4.8 PERIODIC SERVICE............................................................................................................................................. 10
4.9 TROUBLESHOOTING ............................................................................................................................................ 11
5 TECHNICAL SPECIFICATIONS.......................................................................................................................... 11
5.1 EXTERNAL CONNECTORS.................................................................................................................................... 13
5.2 INTERNAL CONNECTORS .................................................................................................................................... 13
5.3 AMBIENT CONDITIONS........................................................................................................................................ 13
5.4 MECHANICAL SPECIFICATIONS .......................................................................................................................... 14
6 DECLARATION OF CONFORMITY ................................................................................................................... 15
3
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
1 Warnings
Attention! This device produces dangerous voltage above 500V.
The device should be operated only by skilled personnel, in accordance with the local
regulations and the instructions given in this manual.
Before switching on the unit, the experiment set-up should be checked out, and
safety should be assured. High voltage areas have to be sealed off and secured.
In case of suspected damage or malfunction, the device should immediately be put
out of service, and it should be secured against unintentional or accidental
operation.
To provide protection for personnel in case of unit failure, the safety ground must
always be connected! Local regulations about grounding should be taken into
account.
High voltages may still exist even after the switch-off of the device due to capacitive
charge! Capacitances connected to the outputs of the device can possibly remain
charged to dangerous voltages, even after switching off the device
Before removing any covers or modules, switch off the mains switch and disconnect
the unit from the mains!
Fuses have to be replaced by types as rated on the nameplate on the rear of the
unit.
Personal safety must be given the highest priority !
4
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
Warnhinweise
Achtung! Dieses Gerät erzeugt lebensgefährliche Spannungen über 500V.
Vor jeder Inbetriebnahme des Hochspannungsverstärkers sind u.a. folgende Regeln zu
beachten:
Die Inbetriebnahme darf nur von einer Elektrofachkraft im Sinne der
Berufsgenossenschaft der Feinmechanik und Elektrotechnik vorgenommen werden.
Vor der Inbetriebnahme muss die Bedienungsanleitung gelesen und verstanden
worden sein.
Es sind die einschlägigen Bestimmungen und Vorschriften des Gesetzgebers, der
Berufsgenossenschaft und des VDE zu beachten, insbesondere
- DIN-VDE 104 "Errichten und Betreiben elektrischer Prüfanlagen"
(s. auch BGI 891 "Errichten und Betreiben von elektrischen Prüfanlagen")
- Unfallverhütungsvorschrift DGUV Vorschrift 3 / BGV A3
"Elektrische Anlagen und Betriebsmittel"
Das Gerät darf nur als Bestandteil eines im Ganzen den Vorschriften für den Umgang
mit Hochspannung genügenden Gesamtaufbaus betrieben werden!
Sollte der Verdacht bestehen, dass das Gerät beschädigt ist oder Fehlfunktionen
zeigt, ist es umgehend außer Betrieb zu setzen und gegen beabsichtigten oder
unbeabsichtigten Betrieb zu sichern.
Der Erdbolzen auf der Rückplatte des Geräts muss mit dem Zentralen Erdpunkt des
Versuchsaufbaus und dem Schutzleiter verbunden werden. Die örtlichen Vorschriften
über Erdung sind zu beachten.
Die Ausgangssteckverbinder dürfen nur bei spannungsfrei geschaltetem Gerät
betätigt werden! Es besteht sonst die Gefahr eines elektrischen Schlages.
Vor jedem Einschalten des Geräts ist der Versuchsaufbau zu überprüfen und sicher-
zustellen, dass es zu keiner Gefährdung kommen kann. Die Hochspannung
führenden Bereiche müssen vorschriftengerecht abgesperrt oder anderweitig
gesichert sein!
Bei Arbeiten am Versuchsaufbau oder bei Berühren der Ausgangsanschlüsse ist das
Gerät zuvor von der Spannungsversorgung zu trennen.
Im angeschlossenen Versuchsaufbau können evtl. vorhandene Kapazitäten auf
Hochspannung aufgeladen werden. Diese können auch nach Abschalten des Geräts
noch gefährliche Spannungen führen.
Vor dem Öffnen des Geräts ist das Gerät von der Spannungsversorgung zu trennen.
Sollte ein Ersatz der Netzsicherungen erforderlich sein, so ist sicherzustellen, dass
nur Sicherungen der angegebenen Nennstromstärke und Nennspannung als Ersatz
verwendet werden.
Der Personensicherheit ist höchste Priorität einzuräumen!
5
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
2 Overview
This manual covers the following models:
HAR12A 12-channel high voltage amplifier
HAR12 12-channel high voltage amplifier mainframe (BNC output connectors)
HAR12S 12-channel high voltage amplifier mainframe (SHV output connectors)
HAR2 2-channel high voltage amplifier mainframe (SHV output connectors)
HAR2-W 2-channel high voltage amplifier mainframe (SHV output connectors)
HA05B2 single channel high voltage amplifier module family
3 Description
The high voltage amplifier HAR12 is a 3U high 19" rack-mountable unit. Up to twelve
independent channels provide output voltages in the range of –500V to +500V at a load current
of ±2mA each. The gain is 50 and the input voltage range is ±10 V. The channels consist of
HA05B2 amplifier modules.
The amplifier channels are characterized by high accuracy, very high stability and very low
noise. The device can thus be used as a multi channel reference voltage source.
Both the output voltage and the load current of each channel can be displayed on two DVMs.
A rotary switch (CHANNEL) is provided for selection of the channel to be measured.
The output voltages of each channel can be controlled by a control voltage (IN) or by a 10-turn
potentiometer (SETPOINT). Each channel is equipped with a voltage monitor output, current
monitor output and inhibit input.
All amplifier outputs are protected against overload, short circuit, and transient overvoltage.
The HAR2/HAR2-W mainframes accommodate up to two amplifier channels.
HAR2 is a table top unit, HAR2-W is a wall-mount type.
The HAR12 models are supplied by mains voltage. The HAR2 models are supplied by 24VDC
6
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
3.1 Block diagram
1N
IN
-
10K0
A3
SETPOINT
I NHI B
+540V
A2
I-MON
A3
W2
1
2
3
X5
Spannungsregler V1 9
1K00
-10.0V
MAN
V24
VO
I NHI B
A4
V-MON
49R9
INHIB
-540V
X6
X7
CMR
X4

 
+
REM
+10.0V
10R0 OFFSET
W1
1
2
3
The block diagram shows one amplifier channel.
7
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
3.2 Control Voltage Input
The control voltage input (IN) is connected to a differential amplifier to
suppress common mode voltages between the external signal source and
the amplifier. Two jumpers (W1, W2) are provided on each amplifier
module HA05B2 in order to adapt the control voltage input to the signal
source.
W1 connects the input signal reference via 10 to the amplifier signal
ground. W2 adjusts the amplifier gain to the output impedance of the
signal source.
W1
1-2 Common mode voltage / Noise <1 VRMS
or floating signal source
Default
2-3 Common mode voltage / Noise 1...4 VRMS
W2
1-2 Output impedance of signal source <1 Default
2-3 Output impedance of signal source 50
Alternatively, the control voltage can be generated by means of a 10-
turn potentiometer (SETPOINT). The potentiometer supplies –10 V at the
CCW end position (0) and +10 V at the CW end position (10). Zero
position is at 5. Switching between internal and external control voltage
is achieved by a front panel switch (MAN / REM).
3.3 Measuring Circuits / Monitor Outputs
Two monitor outputs (V-MON / I-MON) provide actual values of output voltage and output
current, both of which are normalized to ±10 V. The monitor outputs receive their signal through
a compensated voltage divider. Current measurement takes place differentially across a sense
resistor in the output line. Due to differential measurement, a certain drift of the measured
output current over temperature and output voltage is inevitable (refer to technical
specifications).
If the INHIB-input is active, then an appreciable current flows through the sense resistor. This
current is shown by I-MON even though it does not flow from the output (The current flows into
the inhibit semiconductor switch). This value is masked out in the signal to the DVM.
The monitor outputs are buffered and short-circuit-proof. They can drive capacitive loads
(coaxial cable). They are not designed to drive terminated cables (50/75 ), and they should
not be short circuited during normal operation. Load impedance 4 k.
8
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
3.4 INHIBIT
Each high voltage amplifier channel can be remotely switched off through the INHIB input. The
input is TTL-compatible. A LOW-signal turns on the amplifier. In case of open input or HIGH-
signal, the amplifier is turned off. For manual operation, a 50 : BNC-termination resistor can be
used to statically turn the amplifier channel on.
The Inhibit-signal drives a semiconductor switch, short-circuiting the output (approx. 100 )
within microseconds. The switch conducts independently of the internal supply voltage, even
after the device is switched-off.
The INHIB input is not suitable to achieve a safe state at the amplifier output. It must not be
used for safety relevant purposes.
3.5 Loading Conditions
The amplifiers are designed to drive any combination of resistive and capacitive loads.
Full output voltage is available for resistive loads 250 k. When driving capacitive loads the
reactive current must be taken into consideration. This current into the load capacitance
depends on the capacitance value and the slew-rate: iCL = CL * dv / dt.
The effective load capacitance consists of connected load capacitance, the capacitance of the
output cable, and the capacitance internal to the amplifier. If the output current exceeds the
peak current capability of the amplifier module (refer to the specifications), the output voltage
will become distorted.
The achievable large-signal bandwidth strongly depends on the capacitance of the connected
load.
Particularly with regard to the high speed versions of the amplifier modules, the cable
capacitance may become the dominant part of load capacitance. One meter of typical coaxial
cable has a capacitance of about 100 pF.
Large capacitive loads driven by high frequency signals may result in a DC-offset superimposed
on the output voltage. This occurs if the final value of the desired output voltage can not be
reached periodically.
No damage to the amplifier modules will result from the different conditions mentioned.
9
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
4 Installation and Operation
4.1 General
After unpacking, perform an initial inspection to ensure that the unit is in a good working order.
If the unit was damaged in shipment, notify the carrier immediately.
4.2 Temperature balance
In order to avoid condensation inside the device, the device itself must be able to adopt room
temperature. Please arrange the unpacked device at least 2 hours before usage.
4.3 Functional Test
Before installing the unit in a complete setup, a short test should be performed:
1. Assure that the power switch is off.
2. Disconnect all the signal and high voltage cables from the device.
3. Set all of the SETPOINT-potentiometers to 10.0.
4. Set all input selector switches to REM.
5. Connect the unit to a grounded power outlet and turn the unit on.
6. Connect a 50: BNC-termination impedance to the input INHIB at channel 1.
7. Select channel 1 (CHANNEL).
8. The voltage DVM should display about 0000 ±10;
the current DVM should display about 0000 ±10.
9. Set the input selector switch to MAN.
10. The voltage DVM should display about 500.0;
the current DVM should display about 0000 ±20.
11. Turn the SETPOINT-potentiometer to 0.
12. The output voltage changes from about +500 V to about -500 V.
13. Repeat the test with all the other channels.
14. Switch off the device.
4.4 Output connections
The outputs of the device supply a voltage of higher than 500 V. Connections to the load should
be provided only using connectors and cables with appropriate voltage rating.
Do not mate or unmate the output connector unless the device is switched off!
4.5 Ventilation Requirements
The HAR12 Amplifier Subrack may be used in rack mounted or bench top applications. In either
case, sufficient space must be allowed for cooling air to reach the ventilation inputs on the front
panels and for the fan exhaust air to exit from the rear of the unit.
The HAR2 may not be covered when in use. The unit must not be used without the provided
rubber-feet mounted to the bottom side.
Sufficient space for ventilation must be kept below and above the unit when the HAR2-W is
mounted.
10
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
4.6 Rack Mounting HAR12
The HAR12 Amplifier Subrack is designed to fit in a standard 19" equipment rack. Use the rack
mount brackets at both sides of the front panel to install the unit into a 19" rack.
4.7 Wall Mounting HAR2-W
178mm
132,50 mm
4x
10,2x7mm
160,20mm
37,7mm 57,1mm 37,7mm
4.8 Periodic Service
The unit does not require periodic service.
11
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
4.9 Troubleshooting
If the unit behaves unusual or erratic, shut the power supply off and check all load,
programming, and monitoring connections and circuits. Correct any problems found and retest
the system. If the unit still fails to operate correctly, check the following points:
The displays are off although the unit is connected to a working mains outlet and
switched on:
Check the line fuses located in the IEC-inlet. Replace if necessary
(Fuse type: IEC127-2/V, slow, 3.15A, 250V).
Examine the level of INHIB-Input signals.
Warning
- Before removing any covers or modules, switch off the mains switch and disconnect
the unit from the mains !
- Capacitances connected to the outputs of the device can possibly remain charged to
dangerous voltages, even after switching off the device
- In case of suspected damage or malfunction, the device should immediately be put
out of service, and it should be secured against unintentional or accidental operation.
- Maintenance should be carried out by qualified personnel only.
Please contact the manufacturer before attempting to repair a possibly damaged unit.
5 Technical Specifications
HAR12, HAR12A, HAR12S
Parameter Conditions
Mains voltage 95 – 265 Vac
Mains frequency 47 – 63 Hz
Input current VLine=115Vac, full load 1.0 ARMS
Input current VLine=230Vac, full load 0.5 ARMS
Mains fuses F1, F2 IEC127-2/V, slow, 3.15A,
250V
Protection class I
HAR2, HAR2-W
Parameter Conditions
Supply voltage 22.8 – 25.2 Vdc
Input current VIN=24Vdc, full load 0.6 Adc
12
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
All models
Parameter Conditions
Input voltage range IN -10 V...+10 V
max. Input voltage IN 12 VRMS / ±17VDC
Input impedance IN 50 k
Gain RL = 500 k, control value via IN 50 ±0.2%
Output voltage stability RL = 500 k, control value via IN,
Tamb < ±10 K, t = 24 h
< ±100 ppm f.s.
Load regulation IL = 0 -> 100% < 100 ppm
Temperature coefficient
Output voltage
RL = 500 k, 10.00 V via IN,
Tamb < ±10 K
typ. 5 ppm/K
Output voltage range RL = 500 k -500 V…+500 V
Output offset voltage
- HA05B2
- HA05B2_BA
< ±20 mV
< ±30 mV
Load current range -2 mA...+2 mA
Peak output current
- HA05B2
- HA05B2_BA
driving a capacitive load
> ±2 mA
> ±8 mA
Short circuit current < ±4 mA
Power bandwidth
- HA05B2
- HA05B2_BA
RL = 500 k, CL = 100 pF
500 Hz
15000 Hz
Internal output capacitance
- HA05B2
- HA05B2_BA
1200 pF typ.
100 pF typ.
Ripple / Noise
- HA05B2
- HA05B2_BA
RL = 500 k, CL = 100 pF
10 mVPP / 1 mVRMS
30 mVPP / 3 mVRMS
Scaling V-MON 10 V 500 V ±0.2% f.s.
Scaling I-MON 10 V 2 mA ±0.2% f.s.
Zero point stability I-MON VO=-500 V...+500V,
Tamb < ±10 K
< ±0.2% f.s.
Accuracy DVM (U/I) < ±0.2% f.s.
Zero point stability DVM (I) VO=-500 V...+500V,
Tamb < ±10 K
< ±0.2% f.s.
Input voltage INHIB INHIB=LOW -15...1.5 V
Input voltage INHIB INHIB=HIGH 2.4...+15 V
max. Input voltage INHIB 30 VRMS / ±30VDC
Response time INHIB=>HIGH VO<50 V, CL = 100 pF < 10 µs
Response time INHIB=>LOW VO=500 V, CL = 100 pF ca. 2.5 ms
Signal ground and high voltage ground are connected to chassis ground / protective earth.
13
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
5.1 External Connectors
Signals: BNC
Outputs: BNC (HAR12, HAR12A)
Outputs: SHV (HAR12S, HAR2, HAR2-W)
Power line: IEC320-1 (HAR12, HAR12A, HAR12S)
Earth: Bolt M4 (HAR12, HAR12A, HAR12S)
Power supply: 2 pole Combicon Plug (796634-2) (HAR2, HAR2-W)
5.2 Internal Connectors
Internal connectors for HA05B2 plug-in modules (DIN41612, Type F)
Pins Signal
D2 B2 Z2 +540V
D4 B4 Z4 GND
D6 B6 Z6 VO (Amplifier output)
D8 B8 Z8 GND
D10 B10 Z10 -540V
D12 B12 Z12 GND
D14 B14 Z14 n.c.
D16 B16 Z16 n.c.
D18 B18 Z18 Internal connection, do not connect
D20 B20 Z20 Internal connection, do not connect
D22 B22 Z22 Internal connection, do not connect
D24 B24 Z24 Internal connection, do not connect
D26 B26 Z26 Internal connection, do not connect
D28 B28 Z28 Internal connection, do not connect
D30 B30 Z30 +24V
D32 B32 Z32 GND
5.3 Ambient conditions
Parameter Conditions Min. Max. Unit
Ambient temperature
- Operation
- Storage and transportation
0
-25
+40
+70
°C
°C
Relative humidity
- Operation
- Storage and transportation
Not condensing
5
5
80
95
%
%
14
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
5.4 Mechanical Specifications
HAR12
Parameter Value Unit
Depth 365 mm
Width 482 mm
Height 134 mm
Weight 9.5 kg
HAR2
Parameter Value Unit
Depth 264 mm
Width (HAR2/HAR2-W) 141/177 mm
Height (HAR2/HAR2-W) 139/134 mm
Weight 1.9 kg
© hivolt.de GmbH&Co. KG and WME Power Systems GmbH, Hamburg, Germany
10/2016
15
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
6 Declaration Of Conformity
We declare under sole responsibility that the products
Device: High Voltage Amplifiers
Models: HAR12S
equipped with amplifier modules type HA05B2
HAR2
equipped with amplifier modules type HA05B2
are in accordance with the following European directives:
Low Voltage Directive 2006/95/EG
EMC Directive 2004/108/EG
and comply with the following European standards:
EN 61010-1:2010 Safety requirements for electrical equipment for
measurement, control, and laboratory use -
Part 1: General requirements
EN 61326-1:2013 Electrical equipment for measurement, control and
laboratory use -
EMC requirements - Part 1: General requirements
Classification: Group 1, Class B
Manufacturer:
WME Power Systems GmbH
Oehleckerring 40
D-22419 Hamburg
2016-10-04
Wulf Müller
Managing Director
16
hivolt.de GmbH & Co. KG
Oehleckerring 40 y D-22419 Hamburg y +49 40 53 71 22 80 y +49 40 53 71 22 99 y [email protected] y http://www.hivolt.de
EG-Konformitätserklärung
Hiermit erklären wir, dass die Bauart der nachfolgend bezeichneten Gerätefamilie in der von uns
in den Verkehr gebrachten Ausführung den wesentlichen Anforderungen der unten genannten
EG-Richtlinien entspricht.
Bezeichnung: Hochspannungsverstärker
Typen: HAR12S
ausgerüstet mit Verstärkermodulen Typ HA05B2
HAR2
ausgerüstet mit Verstärkermodulen Typ HA05B2
Einschlägige Richtlinien:
Niederspannungsrichtlinie 2014/35/EU
EMV-Richtlinie 2014/30/EU
Folgende Normen wurden zur Beurteilung der Geräte hinsichtlich der oben genannten
Richtlinien herangezogen:
EN 61010-1:2010 Sicherheitsbestimmungen für elektrische Mess-, Steuer-,
Regel- und Laborgeräte
Teil 1: Allgemeine Anforderungen
EN 61326-1:2013 Elektrische Mess-, Steuer-, Regel- und Laborgeräte –
EMV-Anforderungen – Teil 1: Allgemeine Anforderungen
Klassifizierung: Gruppe 1, Klasse B
Hersteller:
WME Power Systems GmbH
Oehleckerring 40
D-22419 Hamburg
2016-10-04
Wulf Müller
Geschäftsführer
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

hivolt HAR2 Bedienungsanleitung

Kategorie
Audioverstärker
Typ
Bedienungsanleitung

in anderen Sprachen