Endres+Hauser EA Alteration Display module to Display module Mounting Instruction

Typ
Mounting Instruction
Products Solutions Services
Installation Instructions
Alteration Display module to
Display module with WLAN
Proline 300, 400, 500, 500-digital
EA01158D/06/A2/08.23-00
71601542
2024-01-01
EA01158D
Endress+Hauser 3
Altering an existing display to display with WLAN
Proline 300, 400, 500, 500-digital
Table of contents
1 Overview of alteration kit .......................................................... 4
2 Persons authorized to alter the device .............................................. 5
3 Personnel authorized to fit new nameplates ........................................ 5
4 Intended use ...................................................................... 5
5 Safety instructions ................................................................ 6
6 Symbols .......................................................................... 7
7 Tools list .......................................................................... 7
8 Altering the blind version of the transmitter to a transmitter with a display module
and cover with window for Proline 300 ............................................. 8
9 Altering the transmitter with a display module to a transmitter with a display
module and WLAN interface and external antenna for Proline 300, 500 ............. 9
10 Altering the transmitter with a display module to a transmitter with a display
module and WLAN interface and external antenna for Proline 300, 500-digital ..... 13
11 Operating options and characteristics of WLAN antenna ........................... 20
12 Modifications to the product roots and extended order codes in the CER database on
Engine .......................................................................... 22
13 Disposal ......................................................................... 23
EA01158D
4 Endress+Hauser
1 Overview of alteration kit
The installation instructions apply to the following alteration kits:
Product structure Upgrade Alteration kit (contents)
Alteration kits for Proline 300
DKZ001–****AF*** Transmitter without display
To transmitter
With display
1 × display with ribbon cable
1 × display holder
1 × cover with window, 1 × O-ring
1 × wired-on tag plate, 1 × conversion
instructions
DKZ001–****AG*** Transmitter without display
To transmitter
With display and WLAN interface
1 × display with ribbon cable and WLAN
interface
1 × display holder
1 × cover with window
1 × O-ring, 1 × wired-on tag plate
1 × conversion instructions
DKZ001–****FG***+P8 Transmitter with display
And WLAN interface
To transmitter
With display and WLAN interface
including external antenna
1 × display with ribbon cable and WLAN
interface including external antenna and
cable gland
1 × wired-on tag plate,
1 × conversion instructions
Alteration kits for Proline 500
DKZ002–****FGB*** Transmitter with display
To transmitter with display and WLAN
interface
1 × display with ribbon cable and WLAN
interface
1 × wired-on tag plate
1 × conversion instructions
DKZ002–****FGB***+P8 Transmitter with display
To transmitter with display and WLAN
interface including external antenna
1 × WLAN display with ribbon cable and
WLAN interface including external antenna
and cable gland
1 × wired-on tag plate
1 × conversion instructions
Alteration kits for Proline 500-digital
DKZ002–****FGA*** Transmitter with display to transmitter
with display and WLAN interface
1 × WLAN display with ribbon cable and
WLAN interface
1 × wired-on tag plate
1 × conversion instructions
DKZ002–****FGA***+P8 Transmitter with display to transmitter
with display and WLAN interface
including external antenna
1 × WLAN display with ribbon cable and
WLAN interface including external antenna
and cable gland
1 × wired-on tag plate
1 × conversion instructions
EA01158D
Endress+Hauser 5
2 Persons authorized to alter the device
Authorization to perform alterations is dependent on the approval of the measuring device.
The table below shows the authorized group of people in each case.
Measuring device approval Personnel authorized to carry out conversions 1)
Without approval 1, 2, 3
With approval (e.g. IECEx) 1, 2, 3
For custody transfer 4
1) 1 = Qualified specialist on customer side, 2 = Service technician authorized by Endress+Hauser,
3 = Endress+Hauser (return measuring device to manufacturer)
4 = Check with local approval center if installation/conversion or alteration must be performed under supervision.
3 Personnel authorized to fit new nameplates
Measuring device approval Personnel authorized to apply new nameplates 1)
Without approval 2, 3
With approval (e.g. IECEx) 2, 3*
1) 2 = service technician authorized by Endress+Hauser, 3 = Endress+Hauser (return device to manufacturer)
* Note: Some countries/markets require a field inspection in order to change
nameplates. Please act in accordance with national legislation.
4 Intended use
Alteration kits and installation instructions are used to upgrade certain functions of an
Endress+Hauser measuring device.
Only use original parts from Endress+Hauser.
Check in the W@M Device Viewer if the alteration kit is suitable for the measuring device in
question.
EA01158D
6 Endress+Hauser
=
www.endress.com/deviceviewer
Order code Description
Ser. No.: 12345...
=
5 Safety instructions
Only use original parts from Endress+Hauser.
Comply with national regulations governing mounting, electrical installation,
commissioning, maintenance and alteration.
The specialized technical staff involved in the mounting, electrical installation,
commissioning, maintenance, installation and alteration of the measuring devices must
meet the following requirements:
Specialized technical staff must be trained in instrument safety.
Specialized technical staff must be familiar with the individual operating conditions of the
devices.
In the case of Ex-certified measuring devices, they must also be trained in explosion
protection.
The measuring device is energized! Risk of fatal injury from electric shock. Open the
measuring device only when the device is de-energized.
For measuring devices intended for use in hazardous locations, please observe the
guidelines in the Ex documentation (XA).
For measuring devices in safety-related applications in accordance with IEC 61508 or
IEC 61511: following alteration, re-commission the device in accordance with the Operating
Instructions. Document the alteration.
Before removing the device: set the process to a safe state and purge the pipe of dangerous
process substances.
Risk of injury from hot surfaces! Before commencing work: allow the system and measuring
device to cool to a touch-safe temperature.
In the case of devices in custody transfer, the custody transfer status no longer applies once
the seal has been removed.
The Operating Instructions for the device must be followed.
Risk of damaging electronic components! Ensure you have a working environment
protected from electrostatic discharge.
After removing the electronics compartment cover: risk of electrical shock due to missing
touch protection!
Turn the measuring device off before removing internal covers.
Only open the housing for a short period. Avoid foreign objects, moisture or dirt entering
the housing.
EA01158D
Endress+Hauser 7
Replace defective seals only with original seals from Endress+Hauser.
If threads are defective, the measuring device must be repaired.
Threads (e.g. of the electronics compartment cover and connection compartment cover)
must be lubricated if an abrasion-proof dry lubricant is not available. Use acid-free, non-
hardening lubricant.
If, during alteration, spacing is reduced or the dielectric strength of the measuring device
cannot be guaranteed, perform a test on completion of the work (e.g. high-voltage test in
accordance with the manufacturer's instructions).
Service connector:
Do not connect in potentially explosive atmospheres.
Only connect to Endress+Hauser service devices.
Observe the instructions for transporting and returning the device outlined in the Operating
Instructions.
If you have any questions, please contact your responsible www.addresses.endress.com.
6 Symbols
6.1 Symbols for certain types of information
Symbol Meaning
Permitted
Procedures, processes or actions that are permitted.
Forbidden
Procedures, processes or actions that are forbidden.
Tip
Indicates additional information.
1.
,
2.
,
3.
Series of steps
7 Tools list
Allen key
3 mm
Torx screwdriver
T20
Slotted head
screwdriver
0.5 x 3.5 mm
Hexagon wrench Crimping tool
EA01158D
8 Endress+Hauser
8 Altering the blind version of the transmitter to a
transmitter with a display module and cover with
window for Proline 300
1 → 2 →
2.
3 mm
1.
3.
icht unter
Spannung öffnen
Do not open when
energized
sous tension
Power
Ne pas ouvrir
N
I/O
2.5 Nm (1.8 lbf ft)
N
i
c
ht
u
n
t
e
r
a
r
e
ö
f
f
n
e
n
3 → 4
+E
ESC
2.
3.
2. 1.
ö
f
f
n
e
n
a
r
e
N
i
c
ht
u
n
t
e
r
N
i
c
ht
u
n
t
e
r
ö
f
f
n
e
n
a
r
e
3 mm
1.
2.5 Nm (1.8 lbf ft)
2.
3.
EA01158D
Endress+Hauser 9
9 Altering the transmitter with a display module to a
transmitter with a display module and WLAN interface
and external antenna for Proline 300, 500
The external WLAN antenna is not suitable for use in hygienic applications.
1 → 2 →
N
i
c
ht
u
n
t
e
r
ö
f
f
n
e
n
a
r
e
3.
2.
1. 3 mm
+E
ESC
ö
f
f
n
e
n
a
r
e
N
i
c
ht
u
n
t
e
r
3.
1.
1.
2.
3 → 4 →
5 → 6 →
2.
1.
30 mm
4 Nm
2.
1.
ESC
EA01158D
10 Endress+Hauser
7 → 8 →
9 → 10 →
+E
ESC
2.
3.
2. 1.
ö
f
f
n
e
n
a
r
e
N
i
c
ht
u
n
t
e
r
N
i
c
ht
u
n
t
e
r
ö
f
f
n
e
n
a
r
e
3 mm
1.
2.5 Nm (1.8 lbf ft)
2.
3.
11
EA01158D
Endress+Hauser 11
9.1 Mounting the wireless antenna with cable
For detailed information on the electrical connection, see the "Electrical connection"
section of the Operating Instructions for the device.
For detailed information on commissioning, see the "Commissioning" section of the
Operating Instructions for the device.
EA01158D
12 Endress+Hauser
9.2 Modifying the label
9.2.1 Checking the data on tie-on label:
Device serial number
New order code
Attach tie-on label as per the diagram using wire cable and crimp barrels:
1
EA01158D
Endress+Hauser 13
10 Altering the transmitter with a display module to a
transmitter with a display module and WLAN interface
and external antenna for Proline 300, 500-digital
10.1 Aluminum transmitter housing
The external WLAN antenna is not suitable for use in hygienic applications.
1 →
T20
1.
2.
2 →
-+-
ESC
2.
1.
3 →
-+-
ESC
2.
1.
EA01158D
14 Endress+Hauser
4 → 5 →
1.
2.
30 mm
4 Nm
6 → 7 →
8 → 9 →
3.
1.
-+-
ESC
2.
1.
2.
-+-
ESC
EA01158D
Endress+Hauser 15
10 → 11
T20
1.
2.
10.2 Polycarbonate transmitter housing
The external WLAN antenna is not suitable for use in hygienic applications.
1 →
T20
1.
2.
2 →
-+-
ESC
2.
1.
EA01158D
16 Endress+Hauser
3 →
-+-
ESC
2.
1.
4 → 5 →
1.
2.
30 mm
4 Nm
6 → 7 →
Route the antenna cable through
the guide on the rear of the
display.
EA01158D
Endress+Hauser 17
8 → 9 →
3.
1.
-+-
ESC
2.
1.
2.
-+-
ESC
Plug in the display connector (1), guide the ribbon cable for the display
behind the tab on the module bracket (2), secure the display (3).
Route the antenna cable into the
side of the transmitter housing
(1), fold down the electronics
compartment cover (2).
10 → 11
2.
T20
1.
3.
EA01158D
18 Endress+Hauser
10.3 Mounting the wireless antenna with cable
3.
1.
2.
5.
4.
For detailed information on the electrical connection, see the "Electrical connection"
section of the Operating Instructions for the device.
For detailed information on commissioning, see the "Commissioning" section of the
Operating Instructions for the device.
EA01158D
Endress+Hauser 19
10.4 Modifying the label
10.4.1 Checking the data on tie-on label:
Serial number of device
New order code
Attach tie-on label as per the diagram using wire cable and crimp barrels:
1
10.4.2 Fit the nameplate:
Fit the nameplate (optional) according to the existing device labeling (see also Section 3
→  5 Authorized persons).
EA01158D
20 Endress+Hauser
11 Operating options and characteristics of
WLAN antenna
1 2 3
4 5 6
1 Transmitter with external WLAN antenna
2 LED lit constantly: WLAN reception is enabled on measuring device
3 LED flashing: WLAN connection established between operating unit and measuring device
4 Computer with WLAN interface and web browser (e.g. Microsoft Internet Explorer, Microsoft Edge)
for accessing integrated device web server or operating tool (e.g. FieldCare, Device Care)
5 Mobile handheld terminal with WLAN interface and web browser (e.g. Microsoft Internet Explorer,
Microsoft Edge) for accessing integrated device web server or operating tool
(e.g. FieldCare, Device Care)
6 Smartphone or Tablet (e.g. Field Xpert SMT70)
Function WLAN: IEEE 802.11 b/g (2.4 GHz)
Function WLAN: IEEE 802.11 b/g (2.4 GHz)
Access Point with DHCP server (factory setting)
• Network
Function WLAN: IEEE 802.11 b/g (2.4 GHz)
Access Point with DHCP server (factory setting)
• Network
Encryption WPA2-PSK AES-128 (in accordance with IEEE 802.11i)
Configurable WLAN channels 1 to 11
Degree of protection IP67
Available antennas Internal antenna
External antenna (optional)
In the event of poor transmission/reception conditions at the place of
installation.
Available as an accessory .
Only 1 antenna is active at any one time!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Endres+Hauser EA Alteration Display module to Display module Mounting Instruction

Typ
Mounting Instruction