Fig. 10
Presence Time Settings
ON
DIP
123456
MIN MAX
TEST HIGH
SAFE NO
MOTION NO
UNI-DIR.
LOW
NC
NC
BI-DIR.
5 MIN
1 MIN
30 SEC
10 SEC
PRESENCE
TIME
MIN MAX MIN MAXMIN MAX
MOTION AREA ADJUSTMMENT
CENTER
LEFT
RIGHT
TEACH-IN
TÜV NOT TÜV
Carlo Gavazzi Industri A/S, Over Hadstenvej 40, DK-8370 Hadsten, Denmark,
declare that the ESPE type 2 product Guardian 2 is in conformity with:
Low-Voltage Directive 2006/95/EC
EN60947-1: 2007 Low-voltage switchgear and control gear - General rules
EMC Directive 2004/108/EC
EN61326-1: 2006 Electrical equipment for measurement. Control and labora-
tory use – EMC requirements – Part 1: General Requirements
EN61000-3-1: 2008 Electrical equipment for measurement, control and
laboratory use - EMC requirements - Part 3-1: Immunity requirements for
safety-related systems and for equipment intended to perform safety-related
functions (functional safety) - General industrial applications
Machinery Directive 2006/42/EC
EN ISO 13849-1: 2008 Safety of machinery - Safety-related parts of control
systems - Part 1: General principles for design
DIN18650-1: 2005 Building hardware. Powered pedestrian doors.
Part 1: Product requirements and test methods
prEN16005: 2009 Powered pedestrian doors - Safety in use of power pedes-
trian doors - Requirements and test methods
EN 12978: 2003 + A1: 2009
Person authorised to compile the technical file:
K. Soerensen, Carlo Gavazzi Industri A/S, Over Hadstenvej 40,
DK-8370 Hadsten, Denmark
EC type examination No. 44 205 09 555114.
Notified body 0044
TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 Essen, Germany
Hadsten, 3 June 2010, K. Soerensen (R&D Manager)
EC Declaration of Conformity
The sensor surface must be cleaned with soft cotton. Light soap water can be
used. No alcohol must be used as the frontglass can be miscoloured.
Maintenaince
The presence time is used to “hold” the door
open if a person or object is present and not
moving in the presence zon. After the “Presence
time” has expired, the doors will close. If an
person or object has not moved within the
“Presence time”, the person or object will be
stored as part of the background. The “Present
time” can be set on the rotary switch for 10 sec,
30 sec, 1 min or 5 min. See fig. 10
According to DIN18650-1, EN12978, the door control system must have a
test function, which checks the presence detector for correct function and
connection at least once per door cycle.
Test Input
t
t
Active high, test pulse: 12-24 VAC/DC
0 VAC/DC
Active low, test pulse: 12-24 VAC/DC
0 VAC/DC
See test sequence (Operating Diagram) on page 66