HO HSING
HVP 70-4-ED-CE
Programm: D2_X
Parameterblatt - Parameter List - Liste des Parametres - Lista dei Parametri
Lista de Parametros - Lista dos Parâmetros
HVP70-4-ED-CE_2005_10_20.xls / PB40 / Seite 2
Parameter Limits Preset 609-
100101
Nr. Designation * min max 680R
english * T = Technician level, A = Supplier level (=) same as preset
236 Mode "machine class"
0=4180i; 1=4180; 2=609
A 0 2 0 2
Following parameters are adjusted with parameter F-236
001 Maximum sewing speed T 50 9999 1700 800
004 Start back-tacking speed T 50 8000 800 =
005 End back-tacking speed T 50 8000 800 =
054 Motor brake at normal stop A ON OFF ON =
057 Motor stops with a reserve angle after trimming A ON OFF ON =
058 Setting the angle of (PAR 057.TRU) A 1° 360° 20 40
060 Low speed A 50 350 150 220
079 Mode selection for trimming sequence (for TM output signal) A TS T1
080 Mode selection for tension-release sequence (for ML output signal) A L1 =
081 Delayed angles prior to trimmer engaged A 0° 360° 0 55
085 Delayed angles prior to tension-release A 0° 360° 147 140
122 Upper limit of maximum speed A 50 9999 2000 1000
125 Function for needle up/down switch at panel C300 A A G B E
126 Mode selection for [125.USM] A ON OFF ON =
168 Motors holding torque again adj. A 5 400 40 20
169 Low speed gain A 5 400 50 25
170 Gain kp A 10 150 40 20
171 Gain ki A 100 3000 1800 100
172 Gain ks A 1 40 2 1
179 2. Position; needle up A 0° 359° 0
*1
181 Synchronisation point A 0° 359° 0 EP*/*1
183 Needle bar upper dead point A 0° 359° 0 *1
209 Define the source of index (reference) point A UP DN UP DN
EP*: EP = needle goes into needle plate
*1 s. needle position adjust DA-instruction with part no.:
0791 609681
Freigabe Nr.: 0031/07
Datum: 12.12.07
Name: Pm
DÜRKOPP ADLER
Parameterblatt 9800 370001 PB40
Seite-Page-Página 2 /2