Sentiotec IS1 Benutzerhandbuch

Typ
Benutzerhandbuch
Version 04/23 Ident-Nr. 1-026-216
EN
DE
INSTRUCTIONS FOR INSTALLATION AND USE
English
36
Infrared control unit
IS1
P-IS1-T
Table of Contents
1. About this instruction manual 3
2. Important information for your safety 4
2.1. Intended use 4
2.2. Safety information for the installer 5
2.3. Safety information for the user 6
3. Product description 7
3.1. Scope of delivery 7
3.2. Optional accessories 7
3.3. Product functions 7
4. Installation 8
4.1. Preparing for surface mounting 8
4.2. Preparing for recess mounting 9
4.3. Preparing the housing 9
5. Electrical connection 10
5.1. Removing the front cover 12
6. Final assembly 13
6.1. Final assembly - surface mounting 13
6.2. Final assembly - recess mounting 14
6.3. Fitting the sensor 15
7. Adjusting the heating time limit 16
8. Operation 17
8.1. Operating and display elements 17
8.2. Quick start 18
8.3. Description of the functions and control elements 19
9. Troubleshooting 21
10. Disposal 22
11. Technical data 22
EN
Instructions for installation and use p. 3/22
1. About this instruction manual
Read these installation and operating instructions carefully and keep them within
reach when using the infrared control unit. This ensures you can refer to informa-
tion about safety and operation at any time.
Symbols used for warnings
These installation and operating instructions feature warning symbols next to
activities presenting a hazard to the user. Warning symbols must be observed
at all times. This prevents damage to property and injuries, which in the worst
case may be fatal.
The warning symbols contain keywords with the following meanings:
DANGER!
Serious or fatal injury will occur if this warning symbol is not observed.
WARNING!
Serious or fatal injury may occur if this warning symbol is not observe.
CAUTION!
Minor injuries may occur if this warning symbol is not observed.
ATTENTION!
This keyword is a warning that damage to property may occur.
Other symbols
This symbol indicates tips and useful information.
The current installation and operating instructions can also be found in
the downloads section of our website: www.sentiotec.com/downloads.
Instructions for installation and use p. 4/22
2. Important information for your safety
The IS1 infrared control unit has been produced in accordance
with the safety regulations applicable for technical units. However,
hazards may occur during use. You should therefore adhere to
the following safety information and the specic warnings in the
individual chapters.
2.1. Intended use
The IS1 infrared control unit is used to control and regulate the
interior temperature and to operate the cabin light. The infrared
control unit may only be used for controlling one heating circuit with
a maximum capacity of 3.0 kW.
Suitable infrared heaters: DIR-350-R, WIR-350-R, DIR-500-R,
WIR-500-R, DIR-750-R, WIR-750-R, DIR-1300-R, WIR-1300-R,
ECO-350-R, ECO-350-G, ECO-500-R, ECO-500-G, ECO-750-R,
O-IRC-W
Suitable infrared plates: IR-WP-175, IR-WP-100, IR-WP-390, IR-
WP-510, IR-WPHL-510, IR-WPHL-100, IR-WPHL-390, IR-WPHL-175
Only in connection with the optional P-ISX-FF foil sensor.
Any use exceeding this scope is considered improper. Improper
use can result in damage to the product, severe injuries or death.
EN
Instructions for installation and use p. 5/22
2.2. Safety information for the installer
Installation may only be performed by a qualied electrician or
similarly qualied person.
Installation and connection of the infrared control unit may only
be performed when the power supply is disconnected.
The temperature sensor must be mounted in such a way that
ensures it is unaected by the inow of air.
Observe all regulations applicable at the installation location.
For your own safety, consult your supplier in the event of prob-
lems that are not explained in sucient detail in the installation
instructions.
Instructions for installation and use p. 6/22
2.3. Safety information for the user
The device must not be used by children under 8 years old.
The device may only be used by children over 8 years old, by
persons with limited psychological, sensory or mental capabili-
ties or by persons with lack of experience/knowledge under the
following conditions:
When they are supervised.
When they have been shown how to use the device safely
and are aware of the hazards that could occur.
Children must not play with the device.
Children under 14 years old may only clean the device if they
are supervised.
For health reasons, do not use the infrared cabin if you are under
the inuence of alcohol, medication or drugs.
Make sure that no ammable objects have been placed on or
in front of the infrared heater or infrared heat plate before the
infrared control unit is switched on.
For your own safety, consult your supplier in the event of prob-
lems that are not described in sucient detail in the operating
instructions.
EN
Instructions for installation and use p. 7/22
3. Product description
3.1. Scope of delivery
IS1 infrared control unit
1.6 m mains connection cable
1.5 m room sensor with silicone cable
Installation material
Instructions for installation and use
3.2. Optional accessories
IR-IS-A03 Adapter cable for heaters and heat plates (0.3 m)
IR-IS-A25 Adapter cable for heaters and heat plates (2.5 m)
IR-1P2 T-splitter, 2-way
IR-1P3 Splitter, 3-way
IR-1P5 Splitter, 5-way
P-ISX-FF Foil sensor incl. 3 m cable
P-ISX-FUSE Fine fuse connection for light
O-F2 Room sensor
3.3. Product functions
The IS1 infrared control unit is used to regulate the cabin temperature using a
room sensor. Settings can be made for the target temperature, duration and light
using the operating elements. The current temperature is shown on the display.
1 heating circuit for a max. capacity of 3.0 kW enables the connection of infrared
heaters and infrared heat plates.
Installation instructions, only for experts p. 8/22
4. Installation
The infrared control unit can either be surface-mounted or recess mounted.
4.1. Preparing for surface mounting
To mount the control unit on a surface, you need to make cable bushings in the
cabin wall. Refer to the following gure for the positions.
49
85
17,5
34
49
65
80,5
1
7
2 3 4 5 6
1 Sensor cable outlet
2 Mains power line
3 Heater/foils outlet
4 Free
5 Free
6 Light outlet
7 Cable shaft
Caution: If the cable is fed down-
wards through the cable shaft 7, the
sensor cable must be tted with ad-
ditional protective insulation.
EN
Installation instructions, only for experts p. 9/22
4.2. Preparing for recess mounting
Mounting the control unit in a recess requires a cut-out section.
Cut-out section size: 160 mm x 102 mm
Mounting depth: 39.5 mm
4.3. Preparing the housing
102 mm
160 mm
R=5 mm
Ensure that the control unit
has sucient rear ventilation!
Work on the housing must only be carried out using a standard screw-
driver. Using a cordless screwdriver may cause irreparable damage to
the housing.
Remove the four screws in the housing 1.
Take the cover 2 o the control unit.
Loosen the strain reliefs 3.
1
2
3
Installation instructions, only for experts p. 10/22
5. Electrical connection
Before mounting the control unit, the electrical connections must be completed.
Observe the following points when connecting the power:
Installation may only be performed by a qualied electrician or similarly quali-
ed person.
Make sure that the connection cables are properly tted in the terminals. Poorly
tted cables heat up quickly and can result in irreparable damage and re.
N
L
PE
230V 1N ~ 50Hz
16A
3
L N U N
3
N L
ww
rw
3
2
wr bb
bb
2
max. 200W
Mains
Heating system
max. 3.0 kW
Light
Room sensor
Optional foil
sensor
EN
Installation instructions, only for experts p. 11/22
1. Guide the connection cable for the room sensor through the cable bushing
in the middle of the housing cover. Do not, under any circumstances, guide
the sensor cables through the existing openings at the bottom.
2. The inlet and outlet for the heating system and lighting are fed out at the
bottom of the housing.
3. Connect all cables and lines to the control unit according to the connection
diagram.
4. Reattach the strain reliefs which were loosened under point 4.3. Preparing
the housing on page 9.
There is an ex-works wire jumper at the terminal marked “r” (excess
temperature). This should only be removed if a temperature sensor with
safety temperature limiter is connected. The sensor included in the de-
livery does not have a safety temperature limiter.
Foil sensor: the foil sensor is only required for the operation of infrared
foils and infrared heat plates. If a foil sensor is connected to the control
unit, the maximum cabin temperature is limited to 50° C.
At the “b - bterminals, a resistor is tted ex-works. This may only be
removed if a foil sensor is connected.
Installation instructions, only for experts p. 12/22
5.1. Removing the front cover
The front cover must be removed to mount the controller on the wall. To do this,
use a at screwdriver.
Once the control module has been mounted on the wall, replace the cover.
First t the upper edge of the cover into the control unit housing.
Then press the bottom against the housing until the cover clicks into place
again.
Insert the screwdriver into the hole provided at the bottom edge of the control
unit.
The cover is held on by a clip. Press this inwards carefully until the cover
loosens.
Now remove the cover from the control unit.
EN
Installation instructions, only for experts p. 13/22
6. Final assembly
After all the electrical connections have been made, the control unit can be
mounted.
6.1. Final assembly - surface mounting
To attach the control unit, use the 50 mm screws included in the delivery. Do not
use screws with a larger diameter. This could damage the housing irreparably.
DANGER!
When tightening the screws, be careful not to damage any cables in the
wall. This can lead to severe damage and injury.
Work on the housing must only be carried out with a screwdriver. Using
a cordless screwdriver may cause irreparable damage to the housing.
Installation instructions, only for experts p. 14/22
6.2. Final assembly - recess mounting
For recess mounting the control unit is placed in a wall cut-out section and at-
tached using the 16 mm Torx screws included.
DANGER!
When tightening the screws, be careful not to damage any cables in the
wall. This can lead to severe damage and injury.
EN
Installation instructions, only for experts p. 15/22
6.3. Fitting the sensor
The room sensor is tted in the infrared cabin about 30 cm below the ceiling or
according to the cabin manufacturer's instructions.
Attach room sensor 1 to the cabin wall using the two 16 mm wood screws
included.
Lay the 2-pin cable 2 in the cabin wall and secure with cable ties.
CAUTION - incorrect readings: If the room sensor is tted too near
the heater, it will produce incorrect measured values. Maintain a mini-
mum horizontal distance of approx. 30 cm to the heater and approx.
30 cm to the cabin ceiling. Do not t the room sensor above the infrared
heating rods.
1
2
Installation instructions, only for experts p. 16/22
7. Adjusting the heating time limit
The heating time limit for the control unit is set at the factory to 99 minutes. This
can be extended up to 24 hours by setting the jumper as described below. The
jumper set is available as an accessory under the order number O-JUMP.
ATTENTION!
For domestic use, the heating time limit may be extended to a maximum
of 6 hours. The provisions of EN 60335-2-53 must be observed for heat-
ing time limits of more than 6 hours.
Heating time settings can only be made to the exact minute for operating
times of up to 99 minutes. From 99 minutes to 9.9 hours, the operating
time can be set with a precision of 0.1 of an hours (6 minutes). After this,
only in 1 hour increments.
L N U N
N L
JP1
JP2
JP3
Operating time Jumper
99 minutes none
6 hours JP1
12 hours JP2
24 hours JP1 + JP2
EN
Instructions for use for the user p. 17/22
8. Operation
8.1. Operating and display elements
36
2
Operating elements:
1 On/O button
2 Light
3 + button
4 Mode/OK button
5 - button
1
7
8
3
4
6
5
Display elements:
6 Temperature and operating time
display
7 Temperature selection
8 Operating time selection
Fig. 1:Operating and display elements
Instructions for use for the user p. 18/22
8.2. Quick start
Press button 1 to switch on the control unit.
The current cabin temperature appears in display 6 and display 7 lights up.
You can adjust the required temperature with buttons 3 and 5. While you are
making the setting, display 6ashes.
Press button 4 to conrm the temperature and display 6 indicates the
current temperature in the cabin.
Now press button 4 to switch to the time symbol 8.
Press buttons 3 and 5 to set the required operating time.
Press button 4 to conrm the setting or wait until the control unit makes
the setting automatically.
The display now shows the remaining operating time.
Note: If no button is pressed for more than 5 seconds, the control unit
automatically uses the target temperature.
Note: Press button 4 to switch between the symbols 7and 8. The display
then shows the respective value:
Symbol 7: current cabin temperature
Symbol 8: remaining operating time
Note: Press button 1 to enable the control unit to save the settings when
switched o. When the control unit is switched on again with button 1 the
previous settings are retrieved again.
EN
Instructions for use for the user p. 19/22
8.3. Description of the functions and control elements
Observe Fig. 1:Operating and display elements on page 17.
On/O button 1
Use this button to switch the control unit on and o (standby). If the operating
time and temperature have already been set, the control units starts immediately
with the previously selected settings. The settings are saved when switching to
standby.
Light button 2
Here you can switch on the cabin light at any time. even if the control unit is
in standby. The cabin light also stays on once the operating time has elapsed.
+ button 3
Press this button to increase the value of the selected option. Hold down the
button to increase the value more quickly. As soon as you press the button, the
display begins to ash and the target value is shown.
Mode/OK button 4
You can switch between the displays for temperature and the operating time
with this button. The current value is displayed. You can also press this button
to conrm the target value.
- button 5
Press this button to decrease the value of the selected option. Hold down the
button to increase the value more quickly. As soon as you press the button, the
display begins to ash and the target value is shown.
Temperature and duration display 6
When the display is lit up permanently it shows the respective current value. The
target value is displayed when you press button 3 or 5. The display ashes until
you press button 4 or the value is set automatically after 5 seconds. Then the
display is lit up permanently and the actual value is shown again.
Instructions for use for the user p. 20/22
Temperature selector 7
Here you can set the required temperature. Press buttons 3 and 5 to make the
setting. While the target temperature is being displayed, display 6 ashes. You
can now conrm the set value by pressing 4 or wait 5 seconds until the value is
set automatically.
Minimum value: 30° C
Maximum value: 70° C for heater mode, 50° C for foil mode
Operating time selection 8
Here you can set the required operating time. Press buttons 3 and 5 to make the
setting. While the required operating time is being displayed, display 6 ashes.
You can now conrm the set value by pressing 4 or wait 5 seconds until the value
is set automatically.
Note: The maximum operating time is restricted by the heating time limit.
See also 7. Adjusting the heating time limit on page 16.
Operating time Setting precision
< 99 minutes 1 minute
99 minutes - 9.9 hours 0.1 hours (6 minutes)
> 9.9 hours 1 hour
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Sentiotec IS1 Benutzerhandbuch

Typ
Benutzerhandbuch

in anderen Sprachen