Chauvet Maverick Storm 1 Spot Referenzhandbuch

Kategorie
Flutlichter
Typ
Referenzhandbuch

Dieses Handbuch eignet sich auch für

Quick Reference Guide
English EN
Español ES
Français FR
Deutsch DE
Nederlands NL
1
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
About This Guide
The Maverick Storm 1 Spot Quick Reference Guide (QRG) has basic product information such as connection, mounting,
menu options, and DMX values. Download the User Manual from www.chauvetprofessional.com
for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico:
www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany:
www.chauvetlighting.eu/warranty.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period
specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty
extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you
must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product
name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you
specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is
valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France,
Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
DO NOT open this product. It contains no user-serviceable parts.
DO NOT look at the light source when the product is on.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product
to fully acclimate to the surrounding environment before connecting it to power.
CAUTION: This product’s housing may be hot when lights are operating.
Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT submerge this product (IP65). Regular outdoor operation is fine.
DO NOT operate this product if the housing, lenses, or cables appear damaged.
DO NOT connect this product to a dimmer or rheostat.
ONLY connect this product to a grounded and protected circuit.
ONLY use the hanging/mounting bracket or the handles to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
RF Exposure Warning for North America, and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Contact
Outside the US, United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request
support or return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included
Maverick Storm 1 Spot
Seetronic Powerkon IP65 Power Cord
2 Omega Brackets with Mounting Hardware
Quick Reference Guide
EN
2
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Replacing the Fuse
1. Disconnect this product from power.
2. Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Maverick Storm 1 Spot will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Maverick Storm 1 Spot uses a 5-pin DMX data connection for its DMX personalities:
33Ch
and
26Ch
. See the User
Manual for information about connecting and configuring the product for DMX operation.
Signal Connection
The Maverick Storm 1 Spot can link to controller software using an Ethernet connection. If using other Art-Net™ or sACN -
compatible products with the Maverick Storm 1 Spot, you can control each individually on a single network. See the User
Manual for information about how to connect and configure the product for these signals.
Art-Net Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers
have this capability. The Maverick Storm 1 Spot supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from www.chauvetprofessional.com for more details.
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
3
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
Mounting
Before mounting this product, read the Safety Notes. Use at least two mounting points per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting
clamps, go to http://trusst.com/products.
Mounting Diagram
Control Panel Description
Battery Powered Display
Press and hold until menu screen appears (approx 15 sec.).
Followspot Mode
The followspot mode disables the pan and tilt motors, allowing the output of the product to be aimed by hand. To enable
the followspot mode of the Maverick Storm 1 Spot, hold <UP> and <LEFT> while the product is powering on. When the
product is turned off and back on, the pan and tilt will return to normal function.
Button Name Function
<>
<UP>
Navigates upwards through the menu list or increases the numeric value when in a
function
<>
<MENU> Exits from the current menu or function
<>
<DOWN>
Navigates downwards through the menu list or decreases the numeric value when in a
function
<>
<LEFT> Navigates leftwards through the menu list
<>
<ENTER>
Enables the currently displayed menu or sets the currently selected value into the selected
function
<>
<RIGHT> Navigates rightwards through the menu list
Overhead Mounting Surface Mounting
Safety Cable
Mounting
Clamp
Omega
Bracket
(x2)
EN
4
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
Menu Map
Main Level Programming Levels Description
Address 000–512 Network Setting
Network Setup
IP Mode
Manual
Selection of IP modeDHCP
Static
Universe 000–255 Set the Universe
Ip _ _ _._ _ _._ _ _._ _ _ IP setting
SubMask _ _ _._ _ _._ _ _._ _ _ Subnet Mask
Personality
DMX 26CH
NO
Choose 26 Channels of DMX
YES
DMX 33CH
NO
Choose 33 Channels of DMX
YES
Settings
Control Mode
DMX
Signal Selection
WDMX
ArtNet
sACN
Pan Reverse
NO
Reverse the Pan
YES
Tilt Reverse
NO
Reverse the Tilt
YES
Screen Reverse
NO
Manually or automatically reverse the
screen
YES
AUTO
Pan Angle
540
Change the Pan angle360
180
Tilt Angle
270
Change the Tilt angle180
90
BL. O. P/T Move
NO
Enable/disable XY blackout
YES
BL. O. Color Move
NO
Enable/disable color blackout
YES
BL. O. Gobo Move
NO
Enable/disable gobo blackout
YES
Lock Screen
NO
Lock the buttons and touchscreen
YES
Swap XY
NO
Swap the pan and tilt
YES
WDMX Reset
NO
Reset the wireless DMX
YES
Backlight Timer
30S
Set the backlight to turn off
automatically after a chosen time
1M
5M
ON
Loss of Data
Hold
Loss of data setting
Close
Fans
Auto
Change the fan speed modeFull
ECO
Theatrical Dimming
ON
Enable/Disable theatrical dimming
OFF
5
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
Settings
(cont.)
Dimmer Curve
Linear
Set the dimmer curve
Square
I Squa
SCurve
PWM Option
600Hz
PWM selection
1200Hz
2000Hz
4000Hz
6000Hz
15000Hz
Smart Zoom
OFF
Enable/Disable smart zoom feature
ON
Beam Correction
OFF
Enable/Disable the beam correction
ON
Preset Select
PRESET A
Recorded preset menu options PRESET B
PRESET C
Preset Sync
NO Allows recorded preset menu options
to be transferred to other Maverick
Storm 1 Spots in the DMX daisy chain
YES
Reset Function
Pan/Tilt
NO/YES
Reset individual functions to factory
Iris/
Prism
Color/
CMY
Gobo/
Gobo
Rotate
Reset individual functions to factory
Frost
All
Factory Settings
NO
Reset all functions to factory
YES
Main Level Programming Levels Description
EN
6
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
Test
Auto Test Auto test the product
Manual Test
Pan
000–255
Individually test each function/channel
Pan Fine
Tilt
Tilt Fine
P/T Speed
Dimmer
Dimmer Fine
Shutter
Virtual Shaking
Cyan
Magenta
Yellow
CTO
Color
Gobo
Gobo Rotate
Gobo Index
Gobo2
Animation
Animation Rotate
Focus
Focus Fine
Focus Auto
Zoom
Zoom Fine
Prism
Prism Rotate
Iris
Frost
Frost2
CMY Macro
CMY Macro Speed
Special Function
Main Level Programming Levels Description
7
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
Information
Fixture
Information
Ver V_ Current Version
Running Mode _ _ _
Current Mode
DMX Address _ _ _
Temperature _ _ _ Current Temperature
Fixture Hours _ _ _ _ _ Current active hours
Ip _ _ _ _ _ Current IP address
SubMask _ _ _ _ _ Current subnet mask
MAC _ _ _ _ _ MAC address
Fan Information
Base Fan1 Speed _ _ _ _
View speed setting
Base Fan2 Speed _ _ _ _
head Fan1 Speed _ _ _ _
head Fan2 Speed _ _ _ _
Error Information _ _ _ _ _ _ Will appear on screen
Channel
Information
Frequency Hz
Status of individual channel
Pan
000–255
Pan Fine
Tilt
Tilt Fine
P/T Speed
Dimmer
Dimmer Fine
Shutter
Virtual Shaking
Cyan
Magenta
Yellow
CTO
Color
Gobo
Gobo Rotate
Gobo Index
Gobo2
Animation
Animation Rotate
Focus
Focus Fine
Focus Auto
Zoom
Zoom Fine
Prism
Prism Rotate
Iris
Frost
Frost2
CMY Macro
CMY Macro Speed
Special Function
Main Level Programming Levels Description
EN
8
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
DMX Values
33Ch
Channel Function Value Percent/Setting
1Pan 000 255 0–100%
2Fine Pan 000 255 Fine control (16-bit)
3Tilt 000 255 0–100%
4 Fine Tilt 000 255 Fine control (16-bit)
5 Pan/Tilt Speed 000 255 Fast to slow
6 Dimmer 000 255 0–100%
7 Fine Dimmer 000 255 Fine control (16-bit)
8Strobe
000 003 Closed
004 007 Open
008 076 Strobe, slow to fast
077 145 Pulse strobe, slow to fast
146 215 Random strobe, slow to fast
216 255 Open
9 Virtual Strobe
000 001 No function
002 128 Shaking strobe, slow to fast
129 255 Fading shake, slow to fast
10 Cyan 000 255 0–100%
11 Magenta 000 255 0–100%
12 Yellow 000 255 0–100%
13 CTO 000 255 0–100%
14 Color Wheel
000 006 Open
007 013 Red
014 020 Orange
021 027 Green
028 034 Blue
035 041 Magenta
042 048 UV
049 059 CTO
060
187 Split color
188 219 Color scroll, fast to slow
220 223 Stop
224 255 Reverse color scroll, slow to fast
15 Gobo Wheel 1
000 007 Open
008 015 Gobo 1 (Sail Boats)
016 023 Gobo 2 (Radial Dot)
024 031 Gobo 3 (Mower Blade)
032 039 Gobo 4 (Bolts)
040 047 Gobo 5 (Shower Glass)
048 055 Gobo 6 (Ballistic Clouds)
056 063 Gobo 7 (Four Eyes)
064 071 Gobo 7 shaking
072 079 Gobo 6 shaking
080 087 Gobo 5 shaking
088 095 Gobo 4 shaking
096 103 Gobo 3 shaking
104 111 Gobo 2 shaking
112 119 Gobo 1 shaking
120 127 Open
128 191 Gobo scroll, slow to fast
192 255 Reverse gobo scroll, slow to fast
9
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
16 Gobo 1 Rotate
000 063 Rotating gobo index
064 145 Gobo rotation, fast to slow
146 149 Stop
150 231 Reverse gobo rotation, slow to fast
232 255 Bounce effect, short to long
17 Gobo Wheel 1 Indexing 000 255 Fine control (16-bit)
18 Gobo Wheel 2
000 005 Open
006 011 Gobo 1 (Beam)
012 017 Gobo 2 (Bars)
018 023 Gobo 3 (Circles)
024 029 Gobo 4 (Breakup)
030 035 Gobo 5 (Dots)
036 041 Gobo 6 (Circuits)
042 047 Gobo 7 (Triangles)
048 053 Gobo 8 (Forest)
054 063 Gobo 9 (Rainbows)
064 069 Gobo 9 shaking
070 075 Gobo 8 shaking
076 081 Gobo 7 shaking
082 087 Gobo 6 shaking
088 093 Gobo 5 shaking
094 099 Gobo 4 shaking
100 105 Gobo 3 shaking
106 111 Gobo 2 shaking
112 117 Gobo 1 shaking
118 127 Open
128 191 Gobo scroll, slow to fast
192 255 Reverse gobo scroll, slow to fast
19 Animation Wheel 000 255 Animation effect, 0–100%
20
Animation Wheel
Rotate
000 124 Animation wheel rotation, fast to slow
125 130 Stop
131 255 Reverse animation wheel, slow to fast
21 Focus 000 255 0–100%
22 Fine Focus 000 255 Fine control (16-bit)
23 Auto Focus
000 010 No function
011 030 0–5 m
031 050 6 m
051 070 7 m
071 090 8 m
091 110 9 m
111 130 10 m
131 150 12.5 m
151 170 15 m
171 190 17.5 m
191 210 20–60 m
211 255 Auto-detect distance
24 Zoom 000 255 0–100%
25 Fine Zoom 000 255 Fine control (16-bit)
26 Prism
000 004 No function
005 255 Prism effect
27 Prism Rotate
000 127 Rotating prism index
128 189 Prism rotation, fast to slow
190 193 Stop
194 255 Reverse prism rotation, slow to fast
Channel Function Value Percent/Setting
EN
10
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
28 Iris
000 063 Big to small
064 127 Auto change, slow to fast
128 191 Slow expand, fast shrink (slow to fast)
192 255 Slow shrink, fast expand (slow to fast)
29 Frost 1 000 255 0–100%
30 Frost 2 000 255 0–100%
31 CMY Macro
000 009 No function
010 255 CMY macro
32 CMY Macro Speed 000 255 CMY macro speed, fast to slow
33 Control
000 007 No function
008 015 XY blackout
016 023 C blackout
024 031 G blackout
032 039 XY/C blackout
040 047 XY/G blackout
048 055 XY/C/G blackout
056 095 No function
096 103 X reset
104 111 Y reset
112 119 Color reset
120 127 Gobo wheels and rotation reset
128 135 No function
136 143 Prism reset
144 151 No function
152 159 All reset
160 167 Iris reset
168 175 Frost reset
176 183 No function
184 191 CMY reset
192 199 Fan ECO mode
200 207 Fan full speed
208
215 Fan auto
216 220 No function
221 225 Iris fast mode
226 230 Iris smooth mode
231 235 XY swap on
236 240 XY swap off
241 245 No function
246 250 XY smooth mode
251 255 XY fast mode
Channel Function Value Percent/Setting
11
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
26Ch
Channel Function Value Percent/Setting
1Pan 000 255 0–100%
2Fine Pan 000 255 Fine control (16-bit)
3Tilt 000 255 0–100%
4 Fine Tilt 000 255 Fine control (16-bit)
5 Pan/Tilt Speed 000 255 Fast to slow
6 Dimmer 000 255 0–100%
7Strobe
000 003 Closed
004 007 Open
008 076 Strobe, slow to fast
077 145 Pulse strobe, slow to fast
146 215 Random strobe, slow to fast
216 255 Open
8 Virtual Strobe
000 001 No function
002 128 Shaking strobe, slow to fast
129 255 Fade in/out, slow to fast
9Cyan 000 255 0–100%
10 Magenta 000 255 0–100%
11 Yellow 000 255 0–100%
12 CTO 000 255 0–100%
13 Color Wheel
000 006 Open
007 013 Red
014 020 Orange
021 027 Green
028 034 Blue
035 041 Magenta
042 048 UV
049 059 CTO
060 187 Split color
188 219 Color scroll, fast to slow
220 223 Stop
224 255 Reverse color scroll, slow to fast
14 Gobo Wheel 1
000 007 Open
008 015 Gobo 1 (Sail Boats)
016 023 Gobo 2 (Radial Dot)
024 031 Gobo 3 (Mower Blade)
032 039 Gobo 4 (Bolts)
040 047 Gobo 5 (Shower Glass)
048 055 Gobo 6 (Ballistic Clouds)
056 063 Gobo 7 (Dots)
064 071 Gobo 7 shaking
072 079 Gobo 6 shaking
080 087 Gobo 5 shaking
088 095 Gobo 4 shaking
096 103 Gobo 3 shaking
104 111 Gobo 2 shaking
112 119 Gobo 1 shaking
120 127 Open
128 191 Gobo scroll, slow to fast
192 255 Reverse gobo scroll, slow to fast
15 Gobo 1 Rotate
000 063 Rotating gobo index
064 145 Gobo rotation, fast to slow
146 149 Stop
150 231 Reverse gobo rotation, slow to fast
232 255 Bounce effect
EN
12
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
16 Gobo Wheel 2
000 005 Open
006 011 Gobo 1 (Beam)
012 017 Gobo 2 (Bars)
018 023 Gobo 3 (Circles)
024 029 Gobo 4 (Breakup)
030 035 Gobo 5 (Four Eyes)
036 041 Gobo 6 (Circuits)
042 047 Gobo 7 (Triangles)
048 053 Gobo 8 (Forest)
054 063 Gobo 9 (Rainbows)
064 069 Gobo 9 shaking
070 075 Gobo 8 shaking
076 081 Gobo 7 shaking
082 087 Gobo 6 shaking
088 093 Gobo 5 shaking
094 099 Gobo 4 shaking
100 105 Gobo 3 shaking
106 111 Gobo 2 shaking
112 117 Gobo 1 shaking
118 127 Open
128 191 Gobo scroll, slow to fast
192 255 Reverse gobo scroll, slow to fast
17 Animation Wheel 000 255 Animation effect
18
Animation Wheel
Rotate
000 255 Animation wheel rotation, fast to slow
000 255 Stop
000 255 Reverse animation wheel, slow to fast
19 Focus 000 255 0–100%
20 Zoom 000 255 0–100%
21 Prism
000 004 No function
005 255 Prism effect
22 Prism Rotate
000
127 Rotating prism 1 index
128 189 Prism 1 rotation, fast to slow
190 193 Stop
194 255 Reverse prism 1 rotation, slow to fast
23 Iris
000 063 Big to small
064 127 Auto change, slow to fast
128 191 Slow zoom out, fast zoom in (slow to fast)
192 255 Slow zoom in, fast zoom out (slow to fast)
24 Frost 1 000 255 0–100%
25 Frost 2 000 255 0–100%
Channel Function Value Percent/Setting
13
EN
QUICK REFERENCE GUIDE
Maverick Storm 1 Spot QRG Rev. 2
26 Control
000 007 No function
008 015 XY blackout
016 023 C blackout
024 031 G blackout
032 039 XY/C blackout
040 047 XY/G blackout
048 055 XY/C/G blackout
056 095 No function
096 103 X reset
104 111 Y reset
112 119 Color reset
120 127 Gobo wheels and rotation reset
128 135 No function
136 143 Prisms reset
144 151 Framing shutter reset
152 159 All reset
160 167 Iris reset
168 175 Frost reset
176 183 Zoom reset
184 191 CMY reset
192 199 Fan low speed
200 207 Fan full speed
208 215 Fan auto
216 220 No function
221 225 Iris fast mode
226 230 Iris smooth mode
231 235 XY swap on
236 240 XY swap off
241 245 No function
246 250 XY smooth mode
251 255 XY fast mode
Channel Function Value Percent/Setting
ES
14
Maverick Storm 1 Spot GRR Rev. 2
GUÍA DE REFERENCIA RÁPIDA
Acerca de esta Guía
La Guía de Referencia Rápida (GRR) del Maverick Storm 1 Spot contiene información básica sobre el producto, como
conexión, montaje, opciones de menú y valores DMX. Descargue el Manual de Usuario de www.chauvetprofessional.com
para información más detallada.
Exención de Responsabilidad
La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.
GARANTÍA LIMITADA
PARA VER EL REGISTRO DE GARANTÍA Y LOS TÉRMINOS Y CONDICIONES COMPLETOS, VISITE NUESTRO SITIO WEB.
Para clientes en los Estados Unidos y México: www.chauvetlighting.com/warranty-registration.
Para clientes en Reino Unido, República de Irlanda, Bélgica, Países Bajos, Luxemburgo, Francia y Alemania:
www.chauvetlighting.eu/warranty-registration
.
Chauvet garantiza que este producto estará libre de defectos de material y mano de obra en condiciones de uso normales,
durante el periodo especificado, sujeto siempre a las exclusiones y limitaciones establecidas en la garantía limitada
completa de nuestro sitio web. Esta garantía se concede únicamente al comprador original del producto y no es transferible.
Para ejercer los derechos que otorga esta garantía, usted debe proporcionar una prueba de compra en forma de un recibo
de compra original, expedido por un distribuidor autorizado, donde figure el nombre del producto y la fecha de compra. NO
EXISTEN OTRAS GARANTÍAS EXPRESAS NI IMPLÍCITAS. Esta garantía le otorga derechos legales específicos. Es
posible que a usted le asistan otros derechos, que variarán dependiendo del estado o del país. Esta garantía solamente es
válida en los Estados Unidos, Reino Unido, República de Irlanda, Bélgica, Países Bajos, Luxemburgo, Francia, Alemania y
México. Para conocer los términos de garantía en otros países, consulte a su distribuidor local.
Notas de Seguridad
Estas notas de seguridad incluyen información importante sobre el montaje, uso y mantenimiento.
NO abra este producto. No contiene piezas reparables por el usuario.
NO mire a la fuente de luz cuando el producto esté encendido.
Para evitar un desgaste innecesario y alargar su vida útil, desconecte complemente el producto de la alimentación,
mediante el interruptor o desenchufándolo, durante los periodos en los que no se use.
Cuidado: cuando transfiera el producto desde ambientes con temperatura extrema (p. ej., del remolque frío de un camión a
una sala de baile con calor y humedad), puede formarse condensación en la electrónica interna del producto. Para evitar que
se produzca una avería, deje que el producto se aclimate completamente al ambiente antes de conectar la alimentación.
¡CUIDADO! La carcasa de este producto está caliente cuando las luces están en funcionamiento.
Monte este producto en una ubicación con ventilación adecuada, al menos a 20'' (50 cm) de superficies adyacentes.
NO deje ningún material inflamable a menos de 50 cm de este producto mientras esté funcionando o conectado a la
alimentación.
USE un cable de seguridad cuando monte este producto en lo alto.
NO sumerja este producto (IP65). La operación normal en exteriores es correcta.
NO ponga en funcionamiento este producto si sospecha que la carcasa, lentes o cables están dañados.
NO conecte este producto a un atenuador o reostato.
Conecte este producto SOLO a un circuito con toma de tierra y protegido.
Use SOLAMENTE los soportes de colgar/montar o las asas para mover este producto.
En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
La máxima temperatura ambiente es de 113 °F (45 °C). No haga funcionar este producto a temperaturas más altas.
La temperatura de inicio máxima es de -4 °F (-20 °C). No ponga en funcionamiento el producto a temperaturas más bajas.
La temperatura ambiente mínima es de -22 °F (-30 °C). No haga funcionar el producto a temperaturas más bajas.
Cumplimiento de la FCC
Este dispositivo cumple la parte 15, parte B de las normas FCC. El funcionamiento está supeditado al cumplimiento de estas
dos condiciones:
1. Este dispositivo no puede causar interferencias perjudiciales; y
2. Este dispositivo debe aceptar cualquier interferencia recibida, incluyendo las interferencias que puedan causar un
funcionamiento no deseado.
Cualquier cambio o modificación que no haya sido expresamente autorizado por la parte responsable de conformidad puede
anular la potestad del usuario para hacer funcionar el equipo.
Advertencia de exposición a RF para América del Norte y Australia
¡Advertencia!
Este equipo cumple los límites FCC de exposición a radiación establecidos para un entorno no controlado.
Este equipo debe instalarse y manejarse con una distancia mínima de 20 cm entre el radiador y su cuerpo. Este transmisor no
se debe situar junto a ninguna otra antena o transmisor ni hacerse funcionar en combinación con ellos.
Contacto
Fuera de EE. UU., Reino Unido, Irlanda, Benelux, Francia, Alemania o México póngase en contacto con su distribuidor
para solicitar asistencia o devolver un producto. Consulte Contact Us
al final de este GRR para información de contacto.
15
ES
GUÍA DE REFERENCIA RÁPIDA
Maverick Storm 1 Spot GRR Rev. 2
Qué va Incluido
Corriente Alterna
Este producto tiene una fuente de alimentación con detección automática que puede funcionar con un rango de tensión
de entrada de 100–240 VCA, 50/60 Hz.
Enchufe CA
Sustitución del Fusible
1. Desconecte este producto de la alimentación.
2. Utilizando un destornillador Phillips, desatornille la tapa del portafusibles de la carcasa.
3. Quite el fusible fundido del portafusibles y sustitúyalo con uno nuevo del mismo tipo y categoría.
4. Vuelva a atornillar la tapa del portafusibles en su sitio y conecte de nuevo la alimentación.
Enlace DMX
El Maverick Storm 1 Spot funcionará con un controlador DMX usando una conexión serie DMX normal. Hay un manual
DMX disponible en www.chauvetprofessional.com.
Conexión DMX
El Maverick Storm 1 Spot usa una conexión de datos DMX normal para sus personalidades: 33Ch y 26Ch. Vea el
Manual de Usuario para conectar y configurar para funcionamiento DMX.
Conexiones de señal
Puede enlazar el Maverick Storm 1 Spot a un controlador o software controlador usando una conexión DMX, una
conexión Ethernet o ambas. Si está usando otros productos compatibles con Art-Net™, sACN o Kling-Netcon, el
Maverick Storm 1 Spot puede controlar cada uno individualmente en una sola red. Consulte el Manual de usuario para
obtener información sobre cómo conectar y configurar el producto para estas señales.
Conexión Art-Net™
Art-Net™ es un protocolo Ethernet que utiliza TCP/IP para transferir gran cantidad de datos DMX512 usando una
conexión etherCON RJ45 sobre una red de gran tamaño. Hay disponible un documento sobre el protocolo Art-Net™
desde www.chauvetprofessional.com. Chauvet Professional recomienda la utilización de modo Unicast para mejores
resultados.
Conexión sACN
También conocido como ANSI E1.31, el streaming ACN es un protocolo Ethernet que usa las capas y formato de
Architecture for Control Networks (arquitectura para redes de control) para transportar datos DMX512 sobre IP o
cualquier otra red compatible con ACN. El mantenimiento de ACN corre a cargo de la Professional Lighting and Sound
Association (Asociación de Sonido e Iluminación Profesional, PLASA).
RDM (gestión remota del dispositivo)
Remote Device Management (gestión remota del dispositivo) o RDM, es un estándar que permite a los dispositivos con
capacidad DMX una comunicación bidireccional por un cableado DMX existente. El Maverick Storm 1 Spot admite
protocolo RDM, que posibilita información para supervisar cambiar las opciones del mapa de menú. Descargue el
manual de usuario de www.chauvetprofessional.com para una información más detallada.
Maverick Storm 1 Spot
Cable de alimentación Seetronic Powerkon IP65
2 soportes Omega con material de montaje
Guía de Referencia Rápida
Conexión Cable (EE.UU) Cable (Europa) Color del Tornillo
CA Cargado Negro Marrón Amarillo/Bronce
CA Neutro Blanco Azul Plata
CA Tierra Verde/Amarillo Verde/Amarillo Verde
Para evitar un desgaste innecesario y alargar su vida útil, desconecte complemente el producto
de la alimentación, mediante el interruptor o desenchufándolo, durante los periodos en los que
no se use.
ES
16
Maverick Storm 1 Spot GRR Rev. 2
GUÍA DE REFERENCIA RÁPIDA
Montaje
Antes de montar este producto, lea las Notas de Seguridad. Utilice al menos dos puntos de montaje por producto.
Asegúrese de que las abrazaderas de montaje son capaces de soportar el peso del producto. Para nuestra línea
Chauvet de abrazaderas de montaje, visite http://trusst.com/products
.
Diagrama de Montaje
Descripción del Panel de Control
Pantalla alimentada con batería
Pulse y mantenga pulsado hasta que aparezca la pantalla de menú (aprox. 15 s).
Modo de seguimiento
El modo de seguimiento de puntos desactiva los motores de giro e inclinación, lo que permite que la salida del producto
sea dirigida a mano. Para habilitar el modo de seguimiento de puntos del Maverick Storm 1 Spot, mantenga presionados
<UP> y <LEFT> mientras el producto se enciende. Cuando el producto se apaga y se vuelve a encender, la panorámica
y la inclinación volverán a su funcionamiento normal.
Botón Nombre Función
<>
<UP>
Navega hacia arriba por la lista de menú o aumenta el valor numérico cuando está en una
función
<>
<MENU> Sale del menú o función actual
<>
<DOWN>
Navega hacia abajo por la lista de menú o disminuye el valor numérico cuando está en una
función
<>
<LEFT> Navega hacia la izquierda por la lista de menú
<>
<ENTER>
Habilita el menú actualmente en pantalla o configura el valor seleccionado actualmente
dentro de la función seleccionada
<>
<RIGHT> Navega hacia la derecha por la lista de menú
Montaje en Altura Montaje en el Suelo
Abrazadera
de Montaje
Cable de
Seguridad
Soporte
Omega
(x2)
17
ES
GUÍA DE REFERENCIA RÁPIDA
Maverick Storm 1 Spot GRR Rev. 2
Mapa de Menú
Nivel Principal Niveles de Programación Descripción
Address 000–512 Configuración de red
Network
Setup
IP Mode
Manual
Selección del modo IP DHCP
Static
Universe 000–255 Configurar el universo
Ip _ _ _._ _ _._ _ _._ _ _ Configuracian de IP
SubMask _ _ _._ _ _._ _ _._ _ _ Máscara de subred
Personality
DMX 26CH
NO
Escoger 26 canales de DMX
YES
DMX 33CH
NO
Escoger 33 canales de DMX
YES
Settings
Control Mode
DMX
Selección de senal
WDMX
ArtNet
sACN
Pan Reverse
NO
Invertir el movimiento panorámico
YES
Tilt Reverse
NO
Invertir la inclinación
YES
Screen Reverse
NO
Invertir la pantalla manual o
automaticamente
YES
AUTO
Pan Angle
540
Cambiar el angulo panoramico 360
180
Tilt Angle
270
Cambiar el angulo de inclinacion 180
90
BL. O. P/T Move
NO
Habilitar/deshabilitar el blackout XY
YES
BL. O. Color Move
NO
Habilitar/deshabilitar el blackout de
color
YES
BL. O. Gobo Move
NO
Habilitar/deshabilitar el blackout de
gobo
YES
Lock Screen
NO
Bloqueo de los botones y pantalla tactil
PASSCODE: 0920
YES
Swap X/Y
NO
Intercambiar movimiento panorámico y
de inclinación
YES
WDMX Reset
NO
Reiniciar DMX inalámbrico
YES
Backlight Timer
30S
Configura la retroiluminacion para que
se apague transcurrido cierto tiempo
1M
5M
ON
Loss of Data
Hold
Configuracion de perdida de datos
Close
ES
18
Maverick Storm 1 Spot GRR Rev. 2
GUÍA DE REFERENCIA RÁPIDA
Settings
(cont.)
Fans
Auto
Cambiar el modo de velocidad del
ventilador
Full
ECO
Theatrical Dimming
ON
Activar / Desactivar atenuación teatral
OFF
Dimmer Curve
Linear
Configurar la curva del atenuador
Square
I Squa
SCurve
PWM Option
600Hz
Selecciona la frecuencia de emisión
PWM
1200Hz
2000Hz
4000Hz
6000Hz
25000Hz
Smart Zoom
OFF
Activar / desactivar la función de zoom
inteligente
ON
Beam Correction
OFF
Habilitar / deshabilitar la corrección del
haz
ON
Preset Select
PRESET A
Opciones de menú preconfiguradas
grabadas
PRESET B
PRESET C
Preset Sync
NO Permite transferir las opciones de
menú preconfiguradas grabadas a
otros Maverick Storm 1 Spots de la
cadena DMX
YES
Reset Function
Pan/Tilt
YES/NO
Restablecer las funciones individuales
a los valores de fábrica
Iris/
Prism
Color/
CMY
Gobo/
Gobo
Rotate
Frost
All
Factory Settings
NO
Restablecer todas las funciones a los
valores de fábrica
YES
Nivel Principal Niveles de Programación Descripción
19
ES
GUÍA DE REFERENCIA RÁPIDA
Maverick Storm 1 Spot GRR Rev. 2
Test
Auto Test
Hacer una prueba automática del producto
Manual Test
Pan
000–255
Comprobar individualmente cada
función/canal
Pan Fine
Tilt
Tilt Fine
P/T Speed
Dimmer
Dimmer Fine
Shutter
Virtual Shaking
Cyan
Magenta
Yellow
CTO
Color
Gobo
Gobo Rotate
Gobo Index
Gobo2
Animation
Animation Rotate
Focus
Focus Fine
Focus Auto
Zoom
Zoom Fine
Prism
Prism Rotate
Iris
Frost
Frost2
CMY Macro
CMY Macro Speed
Special Function
Nivel Principal Niveles de Programación Descripción
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Chauvet Maverick Storm 1 Spot Referenzhandbuch

Kategorie
Flutlichter
Typ
Referenzhandbuch
Dieses Handbuch eignet sich auch für