Laserscale BL57-RE Benutzerhandbuch

Typ
Benutzerhandbuch
BL57-RE
LASERSCALE / LASERSCALE
Instruction Manual / Bedienungsanleitung
Scale Unit / Maßstabseinheit
Read all the instructions in the manual carefully before use and strictly follow them.
Keep the manual for future references.
Lesen Sie die ganze Anleitung vor dem Betrieb aufmerksam durch und folgen Sie beim
Betrieb des Geräts den Anweisungen. Bewahren Sie diese Bedienungsanleitung zum
späteren Nachlesen griffbereit auf.
BL57-RE
BL57-RE
(E) (1)
Safety Precautions
Magnescale Co., Ltd. products are designed in full consideration of safety. However, improper
handling during operation or installation is dangerous and may lead to fire, electric shock or
other accidents resulting in serious injury or death. In addition, these actions may also worsen
machine performance.
Therefore, be sure to observe the following safety precautions in order to prevent these types of
accidents, and to read these “Safety Precautions” before operating, installing, maintaining, in-
specting, repairing or otherwise working on this unit.
Warning indication meanings
The following indications are used throughout this manual, and their contents should be under-
stood before reading the text.
Warning
Failure to observe these precautions may lead to fire, electric shock or other accidents resulting
in serious injury or death.
Caution
Failure to observe these precautions may lead to electric shock or other accidents resulting in
injury or damage to surrounding objects.
Symbols requiring attention
Symbols prohibiting actions
Symbols specifying actions
CAUTION ELECTRICAL
SHOCK
FINGER JAM
DO NOT
DISASSEMBLE
UNPLUG-
GING
LASER BEAM
(2) (E)
BL57-RE
CLASS 1 LASER PRODUCT
LASERSCHUTZKLASSE 1 PRODUKT
TO EN 60825
Warning
Do not use this unit with voltages other than the specified supply voltages as this may
result in fire or electric shock.
Do not perform installation work with wet hands as this may result in electric shock.
Do not disassemble or modify the unit as this may result in injury or damage the
internal circuits.
This device is a class 1 laser product using a semiconductor laser with wavelength of
790 nm that is outside the visible range. The maximum output of the laser is 6 mW
(class 3B).
Although the laser beams emitted from the head interior are invisible to the eye, they
are hazardous to the human body. Therefore, never disassemble the scale unit, or try
to look into it from the sealed section of the scale unit. Also, never insert foreign ob-
jects into the sealed section of the scale unit.
Caution
Be sure to check the machine and device conditions to ensure work safety before
working on the machine.
Be sure to cut off the power supply and other sources of drive power before working
on the machine. Failure to do so may result in fire or accidents.
When turning on the power supply or other sources of drive power to operate the
machine, take care not to catch your fingers in peripheral machines and devices.
BL57-RE
(E) (3)
CAUTION
Use of controls or adjustments or perfomance of procedures other than those specified herein may result in haz-
ardous radiation exposure.
q Specification/DHHS label
w Laser Danger label
e FCC label
See Manual
THIS CLASS A DIGITAL DEVICE COMPLIES WITH PART 15 OF THE FCC
RULES AND THE CANADIAN ICES-003.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS
DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE. AND (2) THIS DEVICE
MUST ACCEPT ANY INTERFERENCE RECEIVED. INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME
NMB-003 DU CANADA.
3-188-177-22
q
w
e
CERTIF I CAT ION
PO
PO
WER
R
SU
SU
PPLY : DC
+
5V
5V
Magnescale Co
Magnescale Co
., Ltd.
MAD
AD
E
E
I N
N
JAP
AP
AN
PRO DUCT
CT
CO
CO
MPL I ES
ES
WI
WI
TH
TH
D H H S
S
R UL
UL
E S
S
21
21
CFR
CFR
S U B C H A PT
PT
E R
J
J
A P P L I CA
CA
BLE
BLE
AT
T
D A T E
E
OF
OF
MAN U F A C T U R E.
E.
BL57
(4) (E)
BL57-RE
Operating Precautions
An antistatic cap is attached to the connector plug of the interface unit. Do not remove this cap until you are
ready to connect the peripherals.
After removing the static electricity proof cap, take care not to touch the connector pins as this might cause
malfunctions.
Be sure to make all connections of the interface unit connector and the peripherals before switching the power on.
Never insert or pull out the connector when the power switch is on.
Do not pull at the cable forcibly or bend it excessively. (Bending radius (inside) Static: 10 mm or more, immobile)
Use the BL57-RE approximately 30 minutes after power is supplied to the unit, when the temperature of the
detector head reaches a stable state.
The BL57-RE is a precision measuring instrument. Handle it with extreme care so that no excessive shock is
applied to it. For transport, be sure to pack it in the same way as it was packed at the time of purchase. Be sure
to always attach the antistatic cap to the connector.
Notes on installation
Take careful note of the following points when installing the scale unit to prevent noise and electromagnetic interfer-
ence from other equipment.
Do not pass the head cable and connection cable through the same duct as the power line.
Install in a location that is at least 0.5 meters separated from sources of high voltage and large currents and
large power relays.
Do not use the cable connecting the detector head to the interface unit in a location where it is likely to be
repeatedly subjected to a bending force (cable bear, etc.). In such a case, bend the cable connected to the
output connector on the interface unit.
Notes on attachment location
Attach the scale in a location as near as possible to the workpiece and measurement object of the machine.
Use this product in an environment with an ambient temperature of 0 to 40 °C.
Do not attach it to a location that is exposed to direct sunlight or warm air or near sources of heat such as motors.
This could adversely affect the accuracy.
If using a water-soluble cutting fluid or other substances, ensure that there is adequate protection so that it does
not adhere to the scale.
Never place objects on top of the attached scale, rest your elbows or feet on the scale when using it, or apply an
excessive amount of pressure to the scale.
Notes on storage
Do not store in locations with high temperatures or high humidity.
This could have an adverse effect on scale performance. Store in a location that is as dry as possible.
General Precautions
When using Magnescale Co., Ltd. products, observe the following general precautions along with those given
specifically in this manual to ensure proper use of the products.
Before and during operations, be sure to check that our products function properly.
Provide adequate safety measures to prevent damages in case our products should develop malfunctions.
Use outside indicated specifications or purposes and modification of our products will void any warranty of the
functions and performance as specified of our products.
When using our products in combination with other equipment, the functions and performance as noted in this
manual may not be attained, depending upon operating environmental conditions. Make full study of the com-
patibility in advance.
BL57-RE
(E) (5)
[For U.S.A. and Canada]
THIS CLASS A DIGITAL DEVICE COMPLIES WITH
PART15 OF THE FCC RULES AND THE CANADIAN
ICES-003. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT
MAY CAUSE UNDERSIGNED OPERATION.
CET APPAREIL NUMERIQUE DE LA CLASSE A
EST CONFORME A LA NORME NMB-003 DU
CANADA.
(6) (E)
BL57-RE
BL57-RE
(E) i
Contents
1. Overview ......................................................................... 1-1
1-1. Introduction .................................................................................................. 1-1
1-2. Main Features ............................................................................................... 1-1
1-3. Series Models ............................................................................................... 1-2
2. Names and Functions of Parts ..................................... 2-1
3. Mounting and Adjustment ............................................. 3-1
3-1. Mounting Precautions .................................................................................. 3-1
3-1-1. When Mounting .......................................................................... 3-1
3-1-2. Mounting Direction ..................................................................... 3-2
3-1-3. Mounting Requirements .............................................................. 3-2
3-2. Mounting Surface Preparations .................................................................... 3-3
3-3. Scale Mounting ............................................................................................ 3-5
3-4. Detector Head Mounting .............................................................................. 3-9
3-5. Signal Adjustment ...................................................................................... 3-10
3-5-1. Signal Adjustment Preparations ................................................ 3-10
3-5-2. Azimuth Adjustment ................................................................. 3-11
3-6. Completion of Mounting and Adjustment.................................................. 3-13
4. Interface Unit .................................................................. 4-1
4-1. Removing and Attaching the Interface Unit Cover ...................................... 4-1
4-2. Installing the Interface Unit ......................................................................... 4-1
4-3. Names of LEDs ............................................................................................ 4-2
4-4. MODE Switch .............................................................................................. 4-3
4-4-1. Detailed Description of MODE Switches ................................... 4-4
4-5. Changing the Settings .................................................................................. 4-5
4-5-1. Changing the Direction ............................................................... 4-5
4-5-2. Changing the Resolution ............................................................. 4-5
4-5-3. Setting the Reference Point Output Signal Width ....................... 4-5
4-5-4. Adjusting the Reference Point .................................................... 4-6
4-5-5. Setting the Reference Point Output and Reference Point
Detection Direction ..................................................................... 4-7
4-5-6. Setting the Alarm Reset Mode .................................................... 4-8
5. Scale Signal Output ....................................................... 5-1
5-1. A/B Signal and Alarm Output Specifications
(For output formats F and G) ....................................................................... 5-1
5-2. Analog Output Specifications (For output format H) .................................. 5-2
6. Input/Output Connectors ............................................... 6-1
6-1. Connectors.................................................................................................... 6-1
6-2. Connection Specifications ............................................................................ 6-3
6-2-1. A/B Signal Output Type .............................................................. 6-3
6-2-2. Analog Output Type .................................................................... 6-5
6-2-3. Output Cable Length (For analog output only) ........................... 6-6
7. Main Specifications........................................................ 7-1
ii (E)
BL57-RE
8. Dimensions ..................................................................... 8-1
8-1. Neoceram Models ........................................................................................ 8-1
8-2. Soda Lime Glass Models ............................................................................. 8-2
9. Trouble Prevention ......................................................... 9-1
BL57-RE
(E) 1-1
1. Overview
1-1. Introduction
The BL57-RE series is an open-type LASERSCALE with integrated detector containing a built-in reference
point. The interface unit is supplied with DC power at +5 V ±5 % for output of A/B and Z signals, or analog
and reference point signals.
1-2. Main Features
Resolution: A/B signal output type : 0.1/0.05, 0.02/0.01 µm
Analog output type : 0.4 µm
Head signal cycle of 0.4 µm allows the interpolation error to be disregarded
Optical integrated circuits employing the latest semiconductor technology are used to achieve a compact
and low-energy design
Theoretically not affected by changes in temperature, air pressure, or by atmospheric fluctuations and
uses low-expansion glass for enhanced measurement stability
Maximum speed: 3,000 mm/s (analog output)
1-2 (E)
BL57-RE
1-3. Series Models
Neoceram models Soda lime glass models
Model name Measuring length
BL57-003RE
C 30 mm
BL57-006RE
C 60 mm
BL57-011RE
C 110 mm
BL57-016RE
C 160 mm
BL57-021RE
C 210 mm
BL57-026RE
C 260 mm
BL57-031RE
C 310 mm
BL57-036RE
C 360 mm
BL57-041RE
C 410 mm
Note:It is possible to use a special specification unit that
has a measuring length of between 420 and 660 mm.
Table 1-1
Fig. 1-1
Examples
BL57-026REGC : Neoceram 260 mm, Open type with reference point, A/B signal output (0.02/0.01 µm)
BL57-006REFB : Soda lime glass 60 mm, Open type with reference point, A/B signal output (0.1/
0.05 µm)
BL57-026REHB : Soda lime glass 260 mm, Open type with reference point, Analog output (0.4 µm)
Model name Measuring length
BL57-006RE
B 60 mm
BL57-016RE
B 160 mm
BL57-026RE
B 260 mm
BL57-036RE
B 360 mm
BL57-046RE
B 460 mm
BL57-056RE
B 560 mm
BL57-066RE
B 660 mm
BL57-076RE
B 760 mm
BL57-086RE
B 860 mm
BL57-096RE
B 960 mm
BL57-106RE
B 1060 mm
Note: It is possible to use a special specification unit that has
a measuring length of between 1070 and 1360 mm.
Scale material C : Neoceram
B: Soda lime glass
Output format F : A/B signal output (0.1/0.05 µm)
G: A/B signal output (0.02/0.01 µm)
H: Analog output (0.4 µm)
Open type (with reference point)
Measuring length (cm)
Model
BL57
***
RE
BL57-RE
(E) 2-1
2. Names and Functions of Parts
Fig. 2-1
Reference plate
Head cable
Detector
head
Interface unit
Mounting screw
Plain washer
Spacer
Scale clamp
Cable clamp
Pan-head screw
Scale
2-2 (E)
BL57-RE
BL57-RE
(E) 3-1
3. Mounting and Adjustment
Follow the procedure below. (For details refer to the corresponding pages.)
3-1. Mounting Precautions....................................................................................................................... 3-1
3-1-1. When Mounting .................................................................................................................... 3-1
3-1-2. Mounting Direction ............................................................................................................... 3-2
3-1-3. Mounting Requirements ........................................................................................................ 3-2
3-2. Mounting Surface Preparations ........................................................................................................ 3-3
3-3. Scale Mounting................................................................................................................................. 3-5
3-4. Detector Head Mounting .................................................................................................................. 3-9
3-5. Signal Adjustment .......................................................................................................................... 3-10
3-5-1. Signal Adjustment Preparations .......................................................................................... 3-10
3-5-2. Azimuth Adjustment ........................................................................................................... 3-11
3-6. Completion of Mounting and Adjustment ...................................................................................... 3-13
3-1. Mounting Precautions
3-1-1. When Mounting
The scale and the detector head are adjusted to each other. If using more than one scale unit, be sure that
the scale-head combinations have matching serial numbers.
Consider the mounting position (Abbe error) and the environmental conditions (temperature, humidity,
vibration and dust) thoroughly.
Do not lead the head cable through the same duct with the power cable. Also, do not bundle the head cable
and power cable together using a tie.
Install in a location that is at least 0.5 meters separated from sources of high voltage and large currents
and large power relays.
Do not use the cable connecting the detector head to the interface unit in a location where it is likely to be
repeatedly subjected to a bending force (cable bear, etc.). In such a case, bend the cable connected to the
output connector on the interface unit.
Use this product in an environment with an ambient temperature of 0 to 40 °C.
Do not attach it to a location that is exposed to direct sunlight or warm air or near sources of heat such as
motors. This could adversely affect the accuracy.
If using a water-soluble cutting fluid or other substances, ensure that there is adequate protection so that
it does not adhere to the scale.
Set the maximum travel of the machine’s moving part shorter than that of the scale.
Scale’s max. travel = measuring length +10 mm/0.39" (5 mm/0.20" per each side)
(If the scale’s max. travel is exceeded, the scale unit signals will not be output and an error will occur.)
For the scale unit, scale signal adjustment is necessary after mounting. When mounting the scale to the
machine, make sure that there is enough space for the adjustment. (See pages 3-3 to 3-13.)
When mounting and adjusting the detector head, do not touch the surface of the head cover indicated by
the arrows in the drawing below.
Fig. 3-1
BL57-RE
3-2 (E)
or
Upside
Downside
3-1-2. Mounting Direction
Mounting can be performed in the vertical or horizontal direction.
The mounting direction shown in the figure is recommended when mounting in the horizontal direction.
Fig. 3-2
3-1-3. Mounting Requirements
Measuring Instruments
Electrical micrometer or lever type dial gauge ......................................................................................(1)
(one that can measure to an accuracy of 2 µm)
Dial gauge stand .....................................................................................................................................(1)
Oscilloscope ...........................................................................................................................................(1)
Capable of 2-quadrant X-Y display
Input sensitivity : DC 0.1 V/DIV
X-Y frequency band : 1 MHz or more
Tools
Hex. wrenches: 3 mm.............................................................................................................................(1)
Philips screwdriver No. 1 ....................................................................................................................... (1)
Philips screwdriver No. 0 ....................................................................................................................... (1)
Miscellaneous
Accessories ...................................................................................................................................... (1 set)
Gauze ................................................................................................................................ (Small amount)
Alcohol .............................................................................................................................. (Small amount)
BL57-RE
(E) 3-3
3-2. Mounting Surface Preparations
1. Check the mounting surface range (the shaded sections in the figure) and accuracy.
2. Check the accuracy of the mounting screw coordinates.
Fig. 3-3
Note: M refers to the machine guide.
Neoceram models
50
±
0.3 (1.969"
±
0.012 ")
Rmax = 12.5S (500 µinch)
Rmax = 6.3S (250 µinch)
0.02 (0.00079")
M
0.01 (0.00039")
0.01 (0.00039")
Scale mounting surface
Detector head mounting surface
18.4
±
0.2 (0.724"
±
0.008")
Unit: mm (inch)
L1
66 (2.598") or more
96 (3.780") or more
146 (5.748") or more
196 (7.717") or more
246 (9.685") or more
296 (11.654") or more
346 (13.622") or more
396 (15.591") or more
446 (17.559") or more
L2
50 (1.969")
75 (2.953")
100 (3.937")
120 (4.724")
120 (4.724")
75 (2.953")
100 (3.937")
L3
75 (2.953")
100 (3.937")
P
4
6
8
8
8
10
10
12
12
25
±
0.2 (0.984"
±
0.008")
For BL57-003RE
*
C, 011RE
*
C, 016RE
*
C,
021RE
*
C, 036RE
*
C, 041RE
*
C
Measuring length
L2
±
1 (0.039")
L2
±
1 (0.039")
BL57-003RE
*
C
BL57-006RE
*
C
BL57-011RE
*
C
BL57-016RE
*
C
BL57-021RE
*
C
BL57-026RE
*
C
BL57-031RE
*
C
BL57-036RE
*
C
BL57-041RE
*
C
30 (1.181")
60 (2.362")
110 (4.331")
160 (6.299")
210 (8.268")
260 (10.236")
310 (12.205")
360 (14.173")
410 (16.142")
Model
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
L2
±
1 (0.039") L2
±
1 (0.039")L3
±
1 (0.039") L3
±
1 (0.039")
19.5 (0.768")
Scale mounting surface
2-M4 depth: 10 (0.394")
P-M4
depth: 6 (0.236")
40 ±0.2 (1.575"
±
0.008")
88
±
0.3 (3.465"
±
0.012")
Detector head mounting surface
25
±
0.2 (0.984"
±
0.008") 25
±
0.2 (0.984"
±
0.008")
42.7 ±0.2
(1.681" ±0.008")
13.5
±
0.2
(0.531"
±
0.008")
6 (0.236")
L1
27 ±0.2
(1.063" ±0.008")
38
(1.496")
28
(1.102")
5
(0.197")
5.5
(0.217")
(10.5)
(0.413")
(5.5)
(0.217")
BL57-RE
3-4 (E)
Soda lime glass models
Fig. 3-4
Note 1: “M” refers to the machine guide.
Note 2: The flatness of the scale mounting surface must be within 0.02 over the range of 7 (width) × 200 (length) mm.
22 (0.866")
(5)
(0.197")
16 ±0.2
(0.630"
±
0.008")
L2
±
1 (0.039")L2
±
1 (0.039")
L3
±
1 (0.039") L3
±
1 (0.039")
L2 ±1 (0.039")L2 ±1 (0.039")
25 ±0.2 (0.984" ±0.008")
50 ±0.3 (1.969" ±0.012")
Detector head mounting surface
Scale mounting surface
P-M4 depth: 6 (0.236")
Rmax = 6.3S (250 µinch)
0.01 (0.00039")
M
16.4 ±0.2 (0.646" ±0.008")
0.02 (0.00079")
Rmax = 12.5S (500 µinch)
0.01 (0.00039")
Detector head mounting surface
Scale mounting surface
27 ±0.2 (1.063" ±0.008")
38
(1.496")
28
(1.102")
4.5 (0.177")
5.5
(0.217")
(5.5) (0.217")
(10.5)
(0.413")
L1
(Note 1)
Unit: mm (inch)
Model
BL57-006REB
BL57-016REB
BL57-026REB
BL57-036REB
BL57-046REB
L1
96 (3.780") or more
196 (7.717") or more
296 (11.654") or more
396 (15.591") or more
496 (19.528") or more
Measuring length
60 (2.362")
160 (6.299")
260 (10.236")
360 (14.173")
460 (18.110")
L2
75 (2.953")
120 (4.724")
75 (2.953")
120 (4.724")
L3
75 (2.953")
75 (2.953")
P
6
8
10
12
14
For BL57-016REB, 036REB
25
±
0.2
(0.984"
±
0.008")
25
±
0.2
(0.984"
±
0.008")
25
±
0.2
(0.984"
±
0.008")
25
±
0.2
(0.984"
±
0.008")
25
±
0.2
(0.984"
±
0.008")
25
±
0.2
(0.984"
±
0.008")
40
±
0.2 (1.575"
±
0.008")
88
±
0.3 (3.465"
±
0.012")
44.2
±
0.2
(1.740"
±
0.008")
2-M4 depth: 10 (0.394")
10 (0.394")
5
(0.197")
L1
27 ±0.2 (1.063" ±0.008")
38
(1.496")
28
(1.102")
5.5
(0.217")
(5.5) (0.217")
(10.5) (0.413")
10 (0.394")
4.5 (0.177")
5
(0.197")
Model
BL57-056REB
BL57-066REB
BL57-076REB
BL57-086REB
BL57-096REB
BL57-106REB
Measuring length
560 (22.047")
660 (25.984")
760 (29.921")
860 (33.858")
960 (37.795")
1060 (41.732")
L1
596 (23.465") or more
696 (27.402") or more
796 (31.339") or more
896 (35.276") or more
996 (39.213") or more
1096 (43.150") or more
L2
100 (3.937")
75 (2.953")
100 (3.937")
100 (3.937")
75 (2.953")
75 (2.953")
L3
175 (6.890")
225 (8.858")
250 (9.843")
250 (9.843")
300 (11.811")
300 (11.811")
L4
75 (2.953")
75 (2.953")
75 (2.953")
75 (2.953")
75 (2.953")
75 (2.953")
NA
2
3
3
4
5
6
P
16
18
20
24
26
30
For BL57-066REB, 096REB, 106REB
25 ±0.2 (0.984" ±0.008")
16 ±0.2
(0.630" ±0.008")
(6)
(0.236")
44.2 ±0.2
(1.740" ±0.008")
Detector head mounting surface
22 (0.866")
Rmax = 6.3S (250 µinch)
0.1 (0.0039")
0.02 (0.00079")
M
16.4 ±0.2
(0.646" ±0.008")
Rmax = 12.5S (500 µinch)
0.02 (0.00079")/
200 (7.874")
Detector head mounting surface
Scale mounting surface
(Note 2)
Scale mounting surface
P-M4 depth: 6 (0.236")
2-M4 depth: 10 (0.394")
Unit: mm (inch)
L2 ±1 (0.039")L2 ±1 (0.039")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
25 ±0.2
(0.984" ±0.008")
L2 ±1 (0.039") L2 ±1 (0.039")
L3 ±1 (0.039")L3 ±1 (0.039")
NA × L4 ±1 (0.039") NA × L4 ±1 (0.039")
50 (1.969")
50 ±0.3 (1.969" ±0.012") 50 ±0.3 (1.969" ±0.012")
25 0.2
(0.984" ±0.008")
BL57-RE
(E) 3-5
0.1 (0.0039")
M
3-3. Scale Mounting
1 Check that there is no dust or other foreign substances on the mounting surface, and mount the reference
plate parallel to the machine guide as shown in the figure. (Fastening torque: 1.4 N · m)
The reference hole is located on the left, as shown in the figure. Adjust at the right side while observing
the parallelism with the lever type dial gauge.
Fig. 3-5
The scale is pressed against the reference plate for parallelism when mounting. The reference plate is
vital to accurate scale mounting. Be sure to always use the supplied screw and mount it exactly as
described in the specifications.
Fig. 3-6
BL57-003RE, 011RE, 016RE, BL57-006RE, 026RE, 031RE, 046RE
021RE, 036RE, 041RE
Note: M refers to the machine guide.
BL57-003RE to 046RE BL57-056RE to 106RE
BL57-056RE, 066RE, 076RE, 086RE, 096RE, 106RE
0.01 (0.00039")
M
+
0.05
Reference ø4 0
M4
×
8
Plain washer (nominal 4)
Reference abutment
surface
M4 × 8
Plain washer
(nominal 4)
Reference abutment
surface
M4
×
8
M4
×
8
Plain washer (nominal 4)
Plain washer
(nominal 4)
Reference abutment
surface
BL57-RE
3-6 (E)
2 Attach the scale clamps loosely (1 or 2 full turns looser than the semi-tightened position) by using the
mounting screws, as shown in the figure.
Fig. 3-7
BL57-003RE BL57-006RE, 026RE, 031RE, 046RE
BL57-011RE, 016RE, 021RE, 036RE, 041RE
BL57-056RE, 066RE, 076RE, 086RE, 096RE, 106RE
M4 × 8
Plain washer (nominal 4)
Reference plate
Scale clamp
M4
×
8
Plain washer (nominal 4)
Reference plate
Scale clamp
Reference plate
Spacer
M4
× 8
Plain washer (nominal 4)
Scale clamp
Reference plate
Spacer
M4
×
8
Plain washer (nominal 4)
Scale clamp
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108

Laserscale BL57-RE Benutzerhandbuch

Typ
Benutzerhandbuch

in anderen Sprachen