Cognex In-Sight 7410 Benutzerhandbuch

Typ
Benutzerhandbuch
In-Sight
®
7000 Series
Vision System
Manual
03/01/2017
Version:5.4.0.20
Note: For the most up-to-date CE declaration and regulatory conformity
information, please refer to the Cognex online support site:
http://www.cognex.com/Support.
Declaration of Conformity
Manufacturer
Cognex Corporation
One Vision Drive
Natick, MA 01760 USA
In-Sight 7010/7010C/7020/7050: Regulatory Model 1AAA
In-Sight 7200/7200C/7210/7230: Regulatory Model 1AAA
In-Sight 7400/7400C/7410/7430: Regulatory Model 1AAA
In-Sight 7402/7402C/7412/7432: Regulatory Model 1AAA
FCC
FCC Part 15, Class A
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference; and (2)
this device must accept any interference received, including interference that may
cause undesired operation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.
KCC In-Sight 7010/7010C/7020/7050: Regulatory Model 1AAA KCC-REM-CGX-1AAA
In-Sight 7200/7200C/7210/7230: Regulatory Model 1AAA KCC-REM-CGX-1AAA
In-Sight 7400/7400C/7410/7430: Regulatory Model 1AAA KCC-REM-CGX-1AAA
In-Sight 7402/7402C/7412/7432: Regulatory Model 1AAA KCC-REM-CGX-1AAA
NRTL V SÜD AM SCC/NRTL OSHA Scheme for UL/CAN 60950-1. Regulatory Model
1AAA.
CB V SÜD AM, IEC/EN 60950-1. CB report available upon request.
EU RoHS Compliant to the latest applicable Directive.
1
China RoHS
Hazardous Substances
Part Name
Lead (Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls (PBB)
Polybrominated
diphenyl ethers
(PBDE)
Regulatory
Model 1AAA
X O O O O O
This table is prepared in accordance with the provisions of SJ/T 11364.
SJ / T 11364
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below
the limit requirement of GB / T26572 - 2011.
GB / T26572 - 2011
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this
part is above the limit requirement of GB / T26572 - 2011.
GB / T26572 - 2011
2
Precautions
Observe these precautions when installing the vision system to reduce the risk of
injury or equipment damage:
l The In-Sight vision system is intended to be supplied by a UL or NRTL listed
power supplywith a 24VDC output rated for at least 2A continuous and a
maximum short circuit current rating of less than 8A and a maximum power
rating of less than 100VA and marked Class 2 or Limited Power Source
(LPS). Any other voltage creates a risk of fire or shockand can damage the
components. Applicable national and local wiring standards and rules must
be followed.
l According to IEC 62471, the white ring light isin Risk Group 1; it isnot
recommended to stare directly into the illumination LEDs when the vision
system isreceiving power. According to IEC 62471, the blue ring light is in
Risk Group 2; CAUTION Possibly hazardous optical radiation emitted
from this product. Do not stare at operating light. May be harmful to the
eyes. The green ring light, the red ring light and the Infrared (IR) ring light
are Exempt Group products, therefore no precautions are required.
l Do not install In-Sight vision systems where they are directly exposed to
environmental hazards such as excessive heat, dust, moisture, humidity,
impact, vibration, corrosive substances, flammable substances, or static
electricity.
l To reduce the risk of damage or malfunction due to over-voltage, line noise,
electrostaticdischarge (ESD), power surges, or other irregularities in the
power supply, route allcables and wires away from high-voltage power
sources.
3
l Do not expose the image sensor to laser light; image sensors can be
damaged by direct, or reflected, laser light. If your application requires the
use of laser light that may strike the image sensor, a lens filter at the
corresponding laser's wavelength is recommended. Contact your local
integrator or application engineer for suggestions.
l The In-Sight vision system does not contain user-serviceable parts. Do not
make electrical or mechanical modifications to In-Sight vision system
components. Unauthorized modifications may void your warranty.
l Changes or modifications not expressly approved by the party responsible
for regulatory compliance could void the user’s authority to operate the
equipment.
l Service loops should be included with all cable connections.
l Cable shielding can be degraded or cables can be damaged or wear out
more quickly if a service loop or bend radius is tighter than 10X the cable
diameter. The bend radius must be at least six inches from the connector.
l Class A Equipment (broadcasting and communication equipment for office
work): Seller and user shallbe notified that this equipment issuitable for
electromagnetic equipment for office work (ClassA) and can be used
outside the home.
l Thisdevice should be used in accordance with the instructions in this
manual.
4
5
Installation
Installation procedures and specifications are presented in detailin the In-Sight
®
7000 Series Vision System Installation Manual, which is installed with In-Sight
Explorer software.
Note:
l Cables are sold separately.
l If any of the standard components appear to be missing or damaged,
immediatelycontact your Cognex Authorized Service Provider (ASP)
or Cognex Technical Support.
CAUTION: All cable connectors are keyed” to fit the connectors on the vision
system; do not force the connections or damage may occur.
Install the Lens (C-Mount Lens
Configuration)
There are two lens configurations available for the vision system: an M12 lens
configuration, and a C-Mount lens configuration. If you purchased a vision system
with the M12 lens configuration, the vision system isshipped with the lens pre-
installed and no additional installation is required. If you purchased a vision system
with the C-Mount lens configuration, you will need to complete the following steps to
install the lens to the vision system.
6
Note:
l Autofocus is not supported for the C-Mount lens configuration.
l If you purchased a vision system with the pre-installed M12 lens, the
lens can be replaced with other M12 lenses. The Cognex Lens Tool
accessory (LNS-M12-TOOLKIT) must be used to replace the M12
lens. For installation instructions, refer to the In-Sight
®
7000 Series
Vision System Optional Configurations, available for download on the
In-Sight support site: http://www.cognex.com/Support/InSight.
CAUTION: Using a non-Cognex lens or replacing the M12 lens without the
Cognex Lens Tool accessory (LNS-M12-TOOLKIT) may cause damage to
the vision system.
1. Remove the protective film covering the threaded lens opening, if present.
2. Attach a C-Mount lens to the vision system. The exact lens focal length
needed depends on the working distance and the field of view required for
your machine vision application.
3. If using a lens cover, attach the lens cover to the vision system.
a. Align the keys on each side of the lens cover with the notches on the
vision system, then push the lens cover down to the vision system
until it stops moving.
CAUTION: The lens cover is "keyed" to fit the vision system;
do not force the connections or damage may occur.
b. Turn the lens cover clockwise until it isin the locked position.
7
Mount the Vision System
The mounting kit includes a mounting bracket and M3 screws (quantity 4) for
mounting the vision system and securing it to a mounting surface. The mounting
bracket also has 1/4 - 20, M6 and flathead mounting holes available for mounting the
vision system to a mounting surface.
Note: The mounting kit is only shipped with vision systems with the M12 lens
configuration. If you purchased a vision system with the C-Mount lens
configuration, the mounting kit isnot included in the box, but can be purchased
as an optional component. Please contact your Cognex sales representative
for more information.
CAUTION:
l When mounting the vision system with the mounting bracket, use the
M3 screws supplied with the mounting kit.
l If using the 1/4 - 20 or M6 screw holes on the mounting bracket to
secure the vision system to a mounting surface, the insertion depth of
the screw should not exceed 7mm. Allowing the mounting screw to
bottom in the mounting hole can damage the vision system.
l If mounting the vision system without the mounting bracket, the
exposed thread length of the M3 screw should not exceed 3mm. The
total length of the M3 screw should be 3mm, plus the thickness of the
mounting materialused. Otherwise, it may damage the vision system.
1. Align the mounting blockwith the mounting holes on the vision system.
2. Insert the M3 screws (quantity4) into the mounting holes and tighten the
screws using a 2.5mm hex wrench; the maximum torque is 0.9039 Nm (8
in-lb).
8
Connect the Light Cable (Optional)
Tip: The space between the vision system connectors is limited; it is
recommended to first connect the Light cable to ensure enough space for the
connection of the Ethernet cable and Breakout cable.
1. Remove the protective cap from the LIGHT connector, if present.
2. Connect the Light cables M12 connector to the vision system's LIGHT
connector.
3. Connect the other end of the Light cable to an external lighting device (for
example, a strobe light).
Connect the Ethernet Cable
1. Connect the Ethernet cables M12 connector to the vision system’s ENET
connector.
2. Connect the Ethernet cables RJ-45 connector to a switch/router or PC, as
applicable.
Connect the Breakout Cable
Note: Unused bare wires can be clipped short or tied back using a tie made of
non-conductive material. Keep all bare wires separated from the +24VDC
wire.
1. Verifythat the 24VDC power supply being used isunplugged and not
receiving power.
9
2. Optionally, connect the I/O or serial wires to an appropriate device (for
example, a PLC or a serial device). Refer to Breakout Cable Specifications
on page12 for wiring details.
3. Attach the Breakout cable's +24VDC (Red wire) and 24V Common (Black
wire) to the corresponding terminalson the power supply. Refer to
Breakout Cable Specifications on page12 for wiring details.
CAUTION: Never connect voltages other than 24VDC. Always
observe the polarity shown.
4. Connect the Breakout cable's M12 connector to the vision system's PWR
connector.
5. Restore power to the 24VDC power supplyand turn it on if necessary.
Install Software and Documentation
To configure an In-Sight vision system, In-Sight Explorer software must be installed
on a networked PC. In-Sight software is available as a free download from the
In-Sight support site: http://www.cognex.com/Support/InSight.
Log On to the Vision System
1. Open the In-Sight Explorer software.
2. From the Get Connected Application Step, select your In-Sight vision
system from the Select an In-Sight Sensor or Emulator group box and press
the Connect button.
10
Vision System Specifications
Specifications
In-Sight
7010/7020/7050/7200/
7210/7230/7400/7410/7430
In-Sight
7010C/7200C/7400C
In-Sight
7402/7412/7432
In-Sight 7402C
Operating
Temperature
0°C to 45°C (32°F to 113°F)
Storage Temperature -30°C to 8C (-22°F to 176°F)
Humidity 90%, non-condensing (Operating and Storage)
Protection IP67 with lens cover properly installed.
Shock (Shipping and
Storage)
80 G Shock per IEC 60068-2-27.
Vibration (Shipping
and Storage)
10G from 10-500Hz with a 50 gram or lighter lens per IEC60068-2-6, FC (C-Mount
lens configuration only).
11
Breakout Cable Specifications
Signal Name (I/O Mode) Wire Color
IN 2 Yellow
IN 3 White/Yellow
HS OUT 2 Brown
HS OUT 3 White/Brown
IN 1/ RS-232 RECEIVE
1
Violet
INPUT COMMON White/Violet
+24VDC Red
24V COMMON Black
OUTPUT COMMON Green
TRIGGER Orange
HS OUT 0 Blue
HS OUT 1/ RS-232 TRANSMIT
2
Grey
SHIELD Bare Wire
1
If hardware handshaking isrequired, an I/O module must be used.
2
If hardware handshaking isrequired, an I/O module must be used.
12
: CE 適合および規制に関る最報については、Cognex ンライン
サポートセンターにアクセスてください。http://www.cognex.com/Support
適合宣言書
製造者
Cognex Corporation
One Vision Drive
Natick, MA 01760 USA
In-Sight 7010/7010C/7020/7050: 規制モデル 1AAA
In-Sight 7200/7200C/7210/7230: 規制モデル 1AAA
In-Sight 7400/7400C/7410/7430: 規制モデル 1AAA
In-Sight 7402/7402C/7412/7432: 規制モデル 1AAA
FCC
FCC (アメリカ連邦通信委員会) 規則第15 章クラス A 準拠
本装置は FCC 規則第 15 章に準拠しり、 次の2 条件を前提として動作します。
(1) 本装置が有害な干渉を起こいこと。(2) 本装置が干渉 (誤動作を引き起こす恐
れの干渉を含む) 受けても耐えること 本装置は高周波を発生・使用・放射するこ
ります。取扱説明書の指示に従わずに設置・使用し場合、無線通信に有害な干
渉を与える可能性がありす。 本装置を住宅地で使用すると有害な電波障害を起こす恐
れがり、こ場合、使用者の負担で障害を是正する必要があります。
KCC In-Sight 7010/7010C/7020/7050: 規制モデ 1AAA KCC-REM-CGX-1AAA
In-Sight 7200/7200C/7210/7230: 規制モデル 1AAA KCC-REM-CGX-1AAA
In-Sight 7400/7400C/7410/7430: 規制モデル 1AAA KCC-REM-CGX-1AAA
In-Sight 7402/7402C/7412/7432: 規制モデル 1AAA KCC-REM-CGX-1AAA
NRTL TÜV SÜD AM SCC/NRTL OSHA Scheme for UL/CAN 60950-1. 規制モデ
1AAA
CB TÜV SÜD AM、IEC/EN 60950-1請求により、CB 報告書を提供しす。
欧州 RoHS 適用可能な最新の指令に準拠。
1
中国 RoHS
有害物質 有害物
部品名
部件名称
(Pb)
水銀 (Hg)
カドミ
(Cd)
六価クロム
(Cr (VI))
六价铬
リ臭素化ビフェ
(PBB)
多溴联苯
リ臭素化ジフェニル
テル (PBDE)
多溴二苯醚
規制モデル
1AAA
X O O O O O
本表は、SJ/T 11364 規定に従って作成されました。
这个标签是根据SJ / T 11364 的规定准备的。
O: この部品のすべての均質材料に含まれる有害物質が、GB / T26572 - 2011 の制限要件を下回っていこと
示します。
表示本部件所有均质材料中含有的有害物质低于GB / T26572 - 2011 的限量要求。
X: この部品に使用されて均質材料の少なくと 1 に含まれている有害物質が、GB / T26572 - 2011
限要件を超えていることを示します。
表示用于本部件的至少一种均质材料中所含的危害物质超过GB / T26572 - 2011 的限制要求。
2
注意
人体への害や器の損傷を防ぐために、ビンシステをインスールる際
次の注意を厳守てください。
l In-Sight シリーズビンシステは、NRTL に準 2A
定格 24VDC、短絡格電 8A 下、電力最大 100 VA
ラス 2 または LPS (Limited Power Source) よる電給を必要と
ます。異なる電を使用ると、火災や感の危険性が生じ、In-Sight のコ
ンポーネント損傷を与る原なります。 それを使用ると
火災感電の危険、コンポーネントに損を与える原因なります。
必要て、および地格および規則にてください。
l IEC 62471 基準は、リングライトはリスクープ 1 (険) に分
されます。電源時に、こを直視ることは推奨さません IEC
62471 では、青色リングライトはリスグループ 2 (険) に分され
ます。こ LED は目有害な光を放するがあります。 この光を直
ないでください。 ると、目に害を与があります。 リングライ
リングライトよび赤外 (IR) リングライトはリスクープ用外
ため、特別な予防措は必要ありません。
l 過度の熱、ほこ、水分、湿度、衝撃、腐食性物、可燃性物
などの境下、In-Sight ビジョンシステを設置しないでください。
l 過電、回線イズ、静電放電 (ESD)、電力サージ、その異常
因した損傷や誤を防止るために、ケーブワイヤはすべて電源
を避けて配線てください。
l ーザー光を画像センサに当てないでください。直接または間接レー
ー光たると、画像センサが傷す可能ります。 センサに
ーザー光たるような場合には、対応するーザーの波長合わせたレ
ンズフィタをお勧めします くのシステインータやアプリケーショ
ンエンジニアにお尋ねください。
3
l In-Sight ビジョンシステムは、ーザが修理できる部はありません。
的または機械的な変を加えなでください。 可なく変造を行った場合は、
保証が無効になります。
l 各種関連の明示的な了なしに変、変造を行った場合は、本
機器の使用を失う可能性があります
l ーブルの配線はサービスループ (長ループ) を設ください
l ーブル径の10 倍にたない小さな曲げ半やサービープを設た場
ケーブシールドのケーブの損傷または磨耗で生
があります。 げ半径はコネタから最 152.4mm (6 インチ) 離れて
る必あります
l ラス A 装置 (目的の放送・通信機器)。本機は、用の電磁 (
ラス A) 、家庭以外使用であることを、販売者あるいは購入者
知す必要がありす。
l のデバイスは、本マニュアルの指示に従て使用してください。
4
5
設置
設置および仕様についの詳細は、In-Sight Explorer ウェアされて
る、『In-Sight® 7000 リーズビジョンシステインストールガイド』をごください。
:
l ーブルは別途ご購入ください。
l 内容の不足や破る場合は、コグネ売代 (ASP)
たは弊社ニカルサポートまでご連絡ください。
注意 : ケーブは、ビジョンシテムのコネクキー溝に合わせてるよう
に設されてますに接うとする、破損するがあります。
レンズの取 (C マウントレンズ)
本ビジョンシテム M12 ンズモデルと C ントレンズモデル 2 種類があり
ます M12 ンズモデルはレンズとリングライトインストールた状出荷
ユーザによるレンズの取り付け業は必ありません。 C ウントンズモデルをお使
いの場合は、のステプにたがってレンズをり付けてくだい。
6
:
l C ウントンズモデルでは、オートーカはサポートてい
ません。
l M12 ンズモデルているレンズは他の M12 レンズに
交換ることきます 換の際は専用工 (M12 レンズ取
LNS-M12-TOOLKIT) をご使用ください は、
In-Sight
®
7000 Series Vision System Optional Configurations』
をご照ください。In-Sight サポート Web サイト
http://www.cognex.com/Support/InSight でダウンロードいただ
ます
注意 : M12 ンズの換には必ずコグ純正 M12 レンズと
(M12 ンズ取り付けキット LNS-M12-TOOLKIT) をご使ください。指定
以外のレンズや工を使用るとビジョンシステる恐があります。
1. ネジきレンズ開口部をカバーしている保護ィルを取します (
ない場合もます)
2. ビンシステ C ントレンズを取り付けます。レンズの離は、マ
ンビョンアリケーションがる視ワークディスタンスによて変
ります
3. レンズカバーを使る場ビジョンシテムンズカーを取ます
a. ンズカバー両側のキーをビジョンシテムの溝にせ、レンズバ
をビンシステに装ます
注意 : ンズカバーはビジョンシムのキー溝に適るよ
うに設されています。無理接続しようとす破損ること
b. ンズカーをロックまで時向にます
7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95

Cognex In-Sight 7410 Benutzerhandbuch

Typ
Benutzerhandbuch