Dometic RMV5301, RMV5305 Installationsanleitung

Kategorie
Kühlschränke
Typ
Installationsanleitung
RMV5301, RMV5305
Absorber refrigerator
Installation Manual. . . . . . . . . . . . . . . . . . . . 12
Absorber-Kühlschrank
Montageanleitung. . . . . . . . . . . . . . . . . . . .27
Réfrigérateur à absorption
Instructions de montage . . . . . . . . . . . . . . .42
Absorptiekoelkast
Montagehandleiding . . . . . . . . . . . . . . . . .57
EN
DE
FR
NL
REFRIGERATION
5 SERIES
RMV530x-I-West.book Seite 1 Mittwoch, 30. Oktober 2019 10:50 22
RMV530x-I-West.book Seite 2 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
3
486 mm
821 mm
478,5 mm
1
> 760 mm
5
4
3
2
1
2
RMV530x-I-West.book Seite 3 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
4
15 – 25 mm
> 25 mm
> 25 mm
3
1
4
40 mm
5
6
115°
2.
1.
RMV530x-I-West.book Seite 4 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
5
451 mm
156 mm
1
2
3
7
373 mm
315 mm
1
2
3
8
RMV530x-I-West.book Seite 5 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
6
1.
2.
A
LS200 LS230
B
C
2.
1.
2.
9
0
RMV530x-I-West.book Seite 6 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
7
A B
CD
EF
GH
IJ
1.
1.
2.
2.
a
RMV530x-I-West.book Seite 7 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
8
A B
DC
FE
GH
IJ
1.
2.
1.
2.
2.
1.
3.
3.
3.
b
RMV530x-I-West.book Seite 8 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
9
AB
C
2.
1.
c
d
RMV530x-I-West.book Seite 9 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
10
br rt sw ws
EN Brown Red Black White
DE Braun Rot Schwarz Weiß
FR Marron Rouge Noir Blanc
NL Bruin Rood Zwart Wit
IN OUT
LLNN
AC
TO GV 12VDCOUT
TO FC
TOP
ABS
HE OUT 12 VDC HE IN
swrt
brbrbrws
S+D+(+)
(+)
(-)
(-)
(+)
(-)
L
NL
A
BCDE FG
1
2
6
5
4
7
8
3
10
11
9
N
12
13
e
RMV530x-I-West.book Seite 10 Mittwoch, 30. Oktober 2019 10:50 22
RMV5301, RMV5305
11
f
RMV530x-I-West.book Seite 11 Mittwoch, 30. Oktober 2019 10:50 22
EN
RMV5301, RMV5305
12
Please read this instruction manual carefully before installation and first
use, and store it in a safe place. If you pass on the product to another
person, hand over this instruction manual along with it.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6 Installing the refrigerator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
7 Reversing the door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8 Put on the door panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9 Connecting the refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
10 Cleaning and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
12 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
13 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
RMV530x-I-West.book Seite 12 Mittwoch, 30. Oktober 2019 10:50 22
EN
RMV5301, RMV5305 Explanation of symbols
13
1 Explanation of symbols
!
!
A
I
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and incorrect
connection voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
!
WARNING! Failure to obey these warnings could result in death
or serious injury.
Explosion hazard
Never open the absorber unit. It is under high pressure and can cause
injury if it is opened.
Only operate the device at the pressure shown on the type plate.
Only use pressure controllers with a fixed setting which comply with
the national regulations (in Europe EN 12864).
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
RMV530x-I-West.book Seite 13 Mittwoch, 30. Oktober 2019 10:50 22
EN
Safety instructions RMV5301, RMV5305
14
Fire hazard
Ensure clean and residue-free handling if silicon sealant or similar is
used. There is a risk of fire if silicone filaments come into contact with
hot parts or naked flames.
Never use a naked flame to check the device for leaks.
Only use propane or butane gas (not natural gas).
Health hazard
Do not operate the device if it is visibly damaged.
If the AC power cable for this device is damaged, it must be replaced
by the manufacturer, customer service or a similarly qualified person in
order to prevent safety hazards.
This device may only be repaired by qualified personnel. Inadequate
repairs may cause serious hazards.
Risk of asphyxiation
Dismantle all device doors for the disposal of the old device and leave
the shelves in the device to prevent accidental enclosure and suffoca-
tion.
!
CAUTION! Failure to obey these cautions could result in minor or
moderate injury.
Electrical shock
Before starting the device, ensure that the power supply line and the
plug are dry.
Risk of crushing
Do not put your fingers into the hinge.
A
NOTICE! Damage hazard
Only hold the device at the body of the device during transport. Never
hold the device at the absorber unit, the cooling fins, the gas pipes,
the door or the control panel.
Make sure that the device circuit is not damaged during
transportation. The refrigerant in the device circuit is highly
flammable.
In the event of any damage to the device circuit (smell of ammonia):
Switch off the device if applicable.
Avoid naked flames and sparks.
Air the room well.
Do not install the device near naked flames or other heat sources (heat-
ers, direct sunlight, gas ovens etc.).
RMV530x-I-West.book Seite 14 Mittwoch, 30. Oktober 2019 10:50 22
EN
RMV5301, RMV5305 Scope of delivery
15
Danger of overheating!
Always ensure sufficient ventilation so that the heat generated during
operation can dissipate. Make sure that the device is sufficiently far
away from walls and other objects so that the air can circulate.
Check that the voltage specification on the type plate is the same as
that of the power supply.
Do not open the refrigerant circuit under any circumstances.
Only use the AC connection cable supplied to connect the device to
the AC mains.
Only use cables with a suitable size.
Never pull the plug out of the socket by the connection cable.
The device may not be exposed to rain.
3Scope of delivery
Refrigerator
•Caps
•Ice-cube tray
Operating manual
Installation manual
4Accessories
Available as accessories (not included in the scope of delivery):
•Fan kit
LS200 ventilation grille
LS230 ventilation grille
Cleaning brush for gas burner
If you have questions regarding the accessories, please contact your local service
partner.
RMV530x-I-West.book Seite 15 Mittwoch, 30. Oktober 2019 10:50 22
EN
Intended use RMV5301, RMV5305
16
5 Intended use
The refrigerator is designed for installation in caravans or motorhomes. It is only suit-
able for cooling, freezing and storing foodstuffs. The refrigerator is not intended for
the proper storage of medicine.
The refrigerator is designed to be operated on a DC power supply and an AC socket
and can be powered by liquid gas (propane or butane). The refrigerator may not be
run on natural gas or city gas. The RMV5305 refrigerator also always requires a per-
manent DC supply.
6 Installing the refrigerator
6.1 Preparing the installation
When installing the refrigerator, note the following:
To enable the refrigerant to circulate properly, the refrigerator may not exceed an
angle of 3°.
Park the vehicle on a level surface with the help of a spirit level.
The refrigerator must be installed so that it is easily accessible for service work,
easy to de-install and install and can be easily removed from the vehicle.
The distance between the refrigerator and the rear wall must be min. 15 mm –
max. 25 mm (fig. 3, page 4).
The refrigerator must be installed in a recess so that it stands firm when the vehicle
is in motion. Note the following dimensions here (fig. 1, page 3).
In the installed state, the door opening angle must be at least 115° for left-hung
and right-hung doors (fig. 6, page 4). Only this will ensure that the freezer com-
partment can be removed or the freezer compartment door opened. This also
applies to the case of the customer changing the side that the door opens on.
The outer wall must be fitted with an air inlet vent (fig. 2 2, page 3) and an outlet
vent (fig. 2 3, page 3) with ventilation grilles so that the heat generated can be
easily released to the outside:
Air inlet vent: Fit the ventilation grille as flush as possible underneath the
burner lid (fig. 2 1, page 3) with a minimum cross-section of 250 cm².
Outlet vent: fit above the refrigerator as far as possible.
If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig. 2 5, page 3) must be provided in the floor for
releasing leaked gas.
RMV530x-I-West.book Seite 16 Mittwoch, 30. Oktober 2019 10:50 22
EN
RMV5301, RMV5305 Installing the refrigerator
17
The air vents must not be covered by vehicle parts (such as an open door or by
installing accessories such as bicycle racks) while operating.
There must be sufficient space at the back of the refrigerator for the air to be able
to circulate around the cooling element.
Fit a heat conduction plate (fig. 2 4, page 3) above the refrigerator so that the
heat does not accumulate in the vehicle.
A distance of more than 25 mm between the refrigerator and rear wall leads to
poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator to create adequate air inlet and outlet
ventilation (fig. 3, page 4). Use a ventilation plate, for example, to do this.
Install the refrigerator so that it is protected from excessive heat, as this leads to
poor performance and increases the power consumption of the refrigerator.
The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and EN 1648-2.
The gas installation must comply with national and local regulations.
European standard: EN 1949.
The refrigerator must be installed in a draught-proof location in accordance with
EN 1949, see chapter “Installing the refrigerator in a draught-proof location” on
page 17.
6.2 Installing the refrigerator in a draught-proof location
Gas-powered refrigerators in caravans or motorhomes must be installed in a
draught-free location according to EN 1949. This means that the combustion air is
not extracted from the interior and the exhaust fumes are prevented from directly
entering the living space.
A suitable seal must be fitted between the rear panel of the refrigerator and the
interior of the vehicle.
!
The manufacturer recommends using a flexible seal to ease removal and installation
for maintenance purposes.
Attach the sealing lips (fig. 4 1, page 4) to a stop rail behind the refrigerator, for
example, by using an adhesive.
When installing, push the refrigerator against the stop rails with the sealing lips.
This then seals the space behind the refrigerator to the interior of the vehicle.
WARNING! Fire hazard!
Do not use flammable materials such as silicone sealants, foam or similar
for the draught-proof installation.
RMV530x-I-West.book Seite 17 Mittwoch, 30. Oktober 2019 10:50 22
EN
Installing the refrigerator RMV5301, RMV5305
18
6.3 Creating the air vents
I
Make an air inlet vent and an air outlet vent in the outer wall. Observe instructions
when doing this, see chapter “Preparing the installation” on page 16 and the
dimensions in fig. 7 and fig. 8, page 5.
If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
Make an air inlet vent in the floor (fig. 5, page 4) behind the refrigerator near the
gas burner. The vent pipe must lead directly outside. This allows leaking
unburned gas to escape outside.
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 5, page 4).
6.4 Installing the ventilation grille
LS200
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
No. in
fig. 7, page 5
Description
1 Installation frame
2 Ventilation grille
3 Winter cover
RMV530x-I-West.book Seite 18 Mittwoch, 30. Oktober 2019 10:50 22
EN
RMV5301, RMV5305 Installing the refrigerator
19
LS230
Proceed as follows (fig. 9, page 6):
Ensure the installation frame is water resistant (A).
Insert the installation frame and screw it down tightly (B).
Insert the ventilation grille and lock it in place (C).
6.5 Securing the refrigerator
!
I
Move the refrigerator into its final location.
Fasten the four screws through the four plastic washers in the sides of the refrig-
erator (fig. 0, page 6), and further into the wall.
No. in
fig. 8, page 5
Description
1 Installation frame
2 Ventilation grille
3 Winter cover
CAUTION!
Only drill through the receptacles provided, otherwise foamed
components, including cables, can be damaged.
NOTE
Attach the side walls or the attached strips so that the screws are tight,
even when under increased loads (while driving).
RMV530x-I-West.book Seite 19 Mittwoch, 30. Oktober 2019 10:50 22
EN
Reversing the door RMV5301, RMV5305
20
7 Reversing the door
Rotary door lock
Replace the door as shown (fig. a, page 7).
2-button door lock
Replace the door as shown (fig. b, page 8).
8 Put on the door panel
A
The door panel must have the following dimensions:
740 x 455 x max. 3 – 3.8 (H x W x D in mm)
Put on the door panel as shown (fig. c, page 9).
NOTICE! Beware of damage
Only ever lay the refrigerator on its side and never on its back. Otherwise
the unit may be damaged.
RMV530x-I-West.book Seite 20 Mittwoch, 30. Oktober 2019 10:50 22
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Dometic RMV5301, RMV5305 Installationsanleitung

Kategorie
Kühlschränke
Typ
Installationsanleitung