Pressalit R8585572000 Benutzerhandbuch

Kategorie
Herzfrequenzmesser
Typ
Benutzerhandbuch

Dieses Handbuch ist auch geeignet für

R8574572/R8575572
R8584572/R8585572
R8594572/R8595572
Change table – Operation and maintenance manual en
Skifteleje Brugs- og vedligeholdelsesvejledning dk
Pflegeliege Gebrauchs- und Pegeanleitung de
Table de change Manuel d’utilisation et d’entretien fr
Aankleedtafels Gebruiks- en onderhoudshandleiding nl
Skötbord Bruks- och underhållsanvisning sv
Stellebord Bruks- og vedlikeholdsveiledning no
Cambiador - Instrucciones de uso y mantenimiento es
Stół do pielęgnacji instrukcja użytkowania i konserwacji pl
换洗台- 操作和维护手册 中文
    
ةيبرعلا
CT 4000/CT 4100
en The warranty covers faults or defects in the material of our products within a period of
3 years from date of invoice. Products subject to minor technical modifi cations and design
deviations E. & O.E.
dk Garantien dækker i 3 år fra fakturadato for materiale- og fabrikationsfejl. Der tages forbe-
hold for trykfejl, tekniske ændringer og modelafvigelser.
de Die Garantie gilt für drei Jahre ab Rechnungsdatum für Material- und Herstellungsfehler.
Druckfehler, technische Änderungen und Modellabweichungen vorbehalten.
fr La garantie couvre les vices de fabrication et de matériaux pour une durée de 3 ans à partir
de la date de facturation. Sous réserve de modifi cations techniques et d’erreurs d’impression.
nl De garantie is tot 3 jaar na factuurdatum geldig voor materiaal- en fabricagefouten. Onder
voorbehoud van drukfouten, technische wijzigingen en modelafwijkingen.
sv Garantin gäller i 3 år från fakturadatum för material- och fabrikationsfel. Med reservation
för tryckfel, tekniska ändringar och modellavvikelser.
no Garantien gjelder i 3 år fra fakturadato for material- og fabrikasjonsfeil. Med forbehold for
trykkfeil, tekniske endringer og modellforskjeller.
es La garantía cubre fallos de material o fabricación durante los 3 años posteriores a partir de
la fecha de factura. Mantenemos reservas en caso de problemas de presión, modifi caciones
técnicas y varia ciones de modelo.
pl Trzyletnia gwarancja obejmuje usterki oraz wady produkcyjne i materiałowe. Produkty
mogą ulec nieznacznym zmianom technicznym i projektowym. Zastrzegamy sobie prawo
do błędów i pominięć.
中文 保修涵盖3年内出现的材料或制造故障或缺陷。产品的技术和设计可能稍微发生变
化,恕不另行通知。
ﺔﯿﺑﺮﻌﻟا قورﻓو ﺔﯾﻧﻓ تﻼﯾدﻌﺗﻟ ﺔﺿرﻋ تﺎﺟﺗﻧﻣﻟا .ماوﻋأ 3 ةرﺗﻔﻟ ﻊﯾﻧﺻﺗﻟا وأ داوﻣﻟا ﻲﻓ بوﯾﻌﻟا وأ ءﺎطﺧﻷا نﺎﻣﺿﻟا ﻲطﻐﯾ
.ةﺎﻧﺛﺗﺳﻣ وﮭﺳﻟاو ﺄطﺧﻟا تﻻﺎﺣ .مﯾﻣﺻﺗﻟا ﻲﻓ ﺔﻔﯾﻔط
English ..........................................................8
Dansk ..........................................................32
Deutsch ........................................................56
Français ........................................................80
Nederlands .....................................................104
Svenska .......................................................128
Norsk .........................................................151
Español........................................................175
Język polski ....................................................199
中文223
ﺔﯾﺑرﻌﻟا . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
3
REF
R8574572/R8584572/R8594572
R8575572/R8585572/R8595572
YYYY-MM-DD
YY-MM-DD
U:XXXV
XX-XX Hz IPXX
P:X W I:XXA
RZZZZYYYXXX-X
(01)0XXXXXXXXXXXXX(10)YYMMDD
xxx kg
xxx lbs ++xxx kg
xxx lbs
xxx kg
xxx lbs
++
2
min
18
min
Pressalit A/S, Pressalitvej 1 DK-8680 Ry
+45 8788 8777, www.pressalit.com
REF
CT 4100
CT 4000
4
REF
230V
R8584572
R8585572
REF
120V
R8594572
R8595572
REF
230V
R8574572
R8575572
Max P U Max I
R8584572, R8585572
R8574572, R8575572
75W 230V 0.3
R8594572, R8595572 36W 120V 0.3
5
CT 4000
R8574572/R8584572/R8594572
CT 4100
R8575572/R8585572/R8595572
R8486 R8489
R8487
++
R8574572/R8584572/
R8594572 75 kg / 165 lbs
227 kg / 500 lbs
R8575572/R8585572/
R8595572 85 kg / 187 lbs
kg
lbs
6
T5256
T5268
Page 1/4
+45 87 88 87 88
+45 87 88 87 89
pressalit.com
Telephone:
Telefax:
E-mail:
Web:
Pressalit
Pressalitvej 1
DK 8680 Ry
Danmark
20XX-01-01
EN Mounting instruction NL Montage-voorschrift
DK Monteringsvejledning SV Monteringsanvisning
DE Montageanleitung NO Monteringsveiledning
FR Notice de montage ES Instrucciones de montaje
PL Instrukcja montażu FI Asennusohje
Subject to alteration without further notice. Ret til ændringer forbeholdes.· Recht auf Änderungen sind
vorbehalten. ·Nous nous réservons le droit d’apporter toutes modifications sans préavis. · Wijzigingen
voorbehouden. ·Rätten till ändringar förbehålles.· Vi forbeholder oss rett til endringer. · Salvo variaciones.
Podlega zmianom bez wcześniejszego powiadomienia. · Pidätämme oikeuden muutoksiin.
7
mm
inch
167
120
750
1829
813
989
1008
1180
1460
6.57
4.72
29.5
3
72.01
32.01
38.94
39.69
46.46
57.48
8
en
Symbols used in this manual.....................................9
General safety .................................................10
Intended use ..................................................11
Using alone (no helper)....................................11
Using with a helper. .......................................12
Intended operator profile ..................................13
Intended user profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating environment....................................13
Contraindications for use ..................................13
Biocompatibility ..........................................13
Operating instructions .........................................14
Folding up and down, CT 4000 .............................14
Folding up and down, CT 4100 .............................15
Height adjustment ........................................16
The safety rail ............................................17
The body belt.............................................17
Cleaning......................................................18
Disinfection...................................................18
Maintenance..................................................19
Maintenance inspection ...................................19
Product label..................................................21
Resetting .....................................................23
Trouble-shooting ..............................................23
Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Electromagnetic immunity.................................26
Electromagnetic emission .................................29
Technical data.................................................30
Storage and transportation .....................................30
Disposal and recycling .........................................31
Original instructions
Content
Mounting instruction
A mounting instruction is included with the product. It can also
be downloaded from pressalit.com.
Operational signage
An operational signage is included with this product. It can also
be downloaded from pressalit.com.
9
en
Symbols used in this manual
The following symbols are used in this manual as well as the associated
documentation supplied with the product.
!WARNING WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
!CAUTION CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury. It may also be used
to alert against unsafe practices.
IMPORTANT IMPORTANT indicates important
information about handling and use
of the product.
NOTICE NOTICE is used to address practices
not related to personal safety.
Hand injury
warning
Head injury
warning
Electricity /
voltage warning
Other specific
warning
Compatible
products Spare parts Power
specifications
EMC related
symbols
++
REF
Product weight Max. user weight Article number/
versions
Do not leave
patient
unattended
10
en
General safety
!CAUTION
• Please comply with these instructions to avoid the product becoming
damaged or destroyed.
• Do not perform repairs, disassembly, or assembly operations,
extensions, re-adjustments or modifications to this product. These
must be carried out by Pressalit or by persons authorized by Pressalit
only.
• Never allow children to operate this product unless under supervision.
The product is not intended for play.
• Never use the product if it is defective or damaged. Do not use a
defective product before it has been repaired.
!WARNING
• Read and understand the manual completely before use. Keep the
manual close to the unit.
• Comply with this manual to avoid accidents involving serious personal
injury.
• Never use or handle this product in other ways than specified in this
manual, as this can put your safety at risk and cause damage to the
product.
• Make sure that everyone who is to install or use the product and its
systems has the necessary information and access to this manual.
NOTICE
• The information in this manual is based on correct fitting of the
product in accordance with our mounting instruction.
• Pressalit cannot be held liable if the product is used in any way which
differs from that described in the guide.
• We reserve the right to amend this manual without prior notice.
11
en
!CAUTION
This product has no manual lowering function, so in case of a power
outage, the lying surface will stay in its current position. It is therefore not
recommended to take the lying surface to the highest position when using the
product alone.
Intended use
Using alone (no helper)
12
en !CAUTION
It is only recommended to take the lying surface to its highest position when
using this product in the presence of a helper.
Using with a helper.
13
en
This product is intended for people who
• need to get changed on a change table
• are above the usual change table age
• are caregivers and need a customized work position
• need to use a change table in combination with person lifts
Intended operator profile
The product is to be used by a person trained in health care and/or trained in
changing a person in their care. It can also be used by self-reliant users.
Intended user profile
The product can be used by adults whose weight does not exceed the
maximum load of 227 kg / 500 lbs.
Operating environment
For indoor use in public changing facilities and schools. Can also be used in
nursing homes and hospitals under normal working conditions.
Contraindications for use
Use of the change table is not recommended for patients with infusion or
insulin pump, inflammatory skin diseases or patients in feverish conditions.
Patients with cardiac insufficiency, cardiovascular diseases, craniocerabral
injury, open wounds, feed or drain lines (e.g. catheter, drainage tube) may use
the change table only after consulting with the attending physician.
Do not use if the patient's weight exceeds 227 kg / 500 lbs.
Biocompatibility
The materials in contact with the skin of the user during the intended use
have been evaluated for their content of harmful substances according to
the procedures in BS EN ISO 10993-1:2020 Biological evaluation of medical
devices – Part 1 and are therefore considered suitable for this purpose.
!CAUTION
Never allow children to operate the unit without supervision of an adult.
• Keep pets and pests away from the unit.
14
en
Operating instructions
Folding up and down, CT 4000
7 kg
15 lbs
Support the table using your
hand or body when folding
it down, to avoid the risk of
damage.
The built-in gas cylinders make it
easy to fold the table up against
the wall after use. Be sure to fold
the safety rail away first.
Take care to avoid injury to hands,
feet and head when in the vicinity of
moving mechanical parts.
NOTICE
Any serious incident that has occurred in relation to the product should be
reported to the manufacturer and the health authorities.
!CAUTION
Always be careful when moving a person to and from the table.
Do not leave the patient unattended.
15
en
The table folds up and down electrically
On the wired remote control for this model, there are two
additional buttons that control the fold-up function.
Press and hold the fold up button to fold the table up, and
press and hold the fold down button to fold the table down.
The movement stops when the button is released.
2 3
Folding up and down, CT 4100
Take care to avoid injury to hands,
feet and head when in the vicinity of
moving mechanical parts.
16
en
Make sure that there are no objects under
the change table when adjusting the
height.
To avoid the risk of strangulation, make
sure that the wired remote control is
placed in its holder when not in use.
Height adjustment
When the change table is installed at the recommended height, it can be
adjusted between 300 and 1000 mm (11.81 and 39.37 inches) above the floor.
The height adjustment is done by pressing the buttons on the frame or on the
wired remote control unit.
Press and hold the Up button to raise the table, and press and hold the Down
button to lower the table. The movement stops when the button is released.
The height adjustment may only be used at temperatures between 15 and 30
degrees Celsius.
17
en
The safety rail
The body belt
To pull the safety rail
up: Release the lock and
pull the safety rail from the
underside of the table, and
swing it upwards. The safety
rail will automatically lock
into position.
The product is equipped with a body belt, that can be used to secure the user.
Pull the belt lock lever up to release the belt lock. Press the lever down again
to lock the body belt.
To fold the safety rail
away: Release the lock
and swing the safety rail
down to the underside of
the table. The safety rail
will automatically lock into
position.
2
1
18
en
Cleaning
Disinfection
When using the change table for multiple patients, it is necessary to both
clean and disinfect it between uses on different patients to prevent the risk of
cross infection.
IMPORTANT
• Do not use an autoclave or other type of steam cleaner.
• Avoid aggressive cleaning agents containing acids.
• Never spray the product directly with a high pressure cleaner.
• Avoid use of abrasive, corrosive or chlorine-based cleaning or
disinfecting products.
The product is to be cleaned with hot water or a mild soapy cleaning agent.
To see which cleaning products have been tested and approved by Pressalit
for the specific product, please visit Pressalit.com and refer to the product’s
item number. Pressalit recommends cleaning the product after installation.
!CAUTION
Always read the material safety data sheet (MSDS) and supplied
instructions of the cleaning, disinfecting or de-scaling agent and comply
with instructions for safe use, dilution, rinsing, drying, handling and
storage of the agent.
19
en
Maintenance
Expected service life of the change table is 10 years, provided that
maintenance is carried out as described below:
It is recommended on a weekly basis to run the motors on the product to their
maximum positions by raising the table to its full height, and then lowering it
to its lowest position, so that the internal parts are lubricated.
It is recommended that inspection is done once a year.
Maintenance inspection
1
1
2
2
Check the hinges and other fittings on the table and the safety rail .
Tighten if necessary.
!CAUTION
Do not perform any type of maintenance inspection on the change table
while a patient is lying on it.
20
en
1
1
1
1
Remove the upper and lower retaining
screws on the lift unit cover and
carefully remove the cover.
• Check the wall brackets and
tighten if necessary.
• Oil moving parts, especially the
sliding brackets .
2
2
2
2
5
6
4
3
3
Disconnect mains before
removing the covers.
• Check all electrical connections to the control box .
• Check the chain wheel for wear.
• Oil the chain .
• Put the unit cover back again and tighten the retaining screws.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270

Pressalit R8585572000 Benutzerhandbuch

Kategorie
Herzfrequenzmesser
Typ
Benutzerhandbuch
Dieses Handbuch ist auch geeignet für