Never leave frying pans
unattended during use as
overheated fat and oil may
catch fire.
If the room where the
cooker hood is to be used
contains a fuel burning
appliance such as a central
heating boiler then this must
be of the room sealed or
balanced flue type. If other
types of flue or appliance are
fitted ensure that there is an
adequate supply of air to the
room. The cooker hood in fact
could extract the air which is
needed for burning. When the
cooker hood and appliances
supplied with energy other
than electricity are
simultaneously in operation the
negative pressure in the room
must not exceed 0,04 mbar in
order to avoid a return of the
gaz emissions. This is possible
through openings in doors,
windows, or air inlet valves
allowing fresh air to enter
the kitchen. In any case, in
connection with the discharge
of exhaust air, the
requirements of the
authorities concerned have
to be observed.
Frittiergeräte, die unter
der Dunstesse betrieben
werden, sind während
der gesamten Betriebsdauer
zu beaufsichtigen:
überhitztes Oel kann die
Haube in Brand setzen.
Wenn in dem Raum
außer der Haube andere,
nicht elektrisch betriebene
Geräte (z.B. Gasöfen)
betrieben werden, muß für
ausreichende Lüftung
gesorgt werden, da beim
Absaugen der Luft durch die
Haube dem Raum die Luft
entnommen wird, die die
Feuerstätte zur Verbrennung
benötigt. Ein gefahrloser
Betrieb ist möglich, wenn bei
gleichzeitgem Betrieb von
Haube und Feuerstätte im
Raum ein Unterdruck von
höchstens 0,04 mbar
erreicht wird und damit
ein Rücksaugen der
Feuerstättenabgase
vermieden wird. Das kann
erreicht werden, wenn durch
nicht verschließbare
Offnungen, z.B. in Türen,
Fenstern, Zuluft-Abluft-
Mauerkasten o.ä. die
Verbrennungsluft
nachströmen kann. In jedem
Fall sind die behördlichen
Vorschriften zu beachten.