6
Installation
GB
Remove the curing cover.
1
Fasten the shower hanger to the base plate.
2
Connect the connector / connect the power supply.
3
Fasten the base plate.
To prevent bolt burn-in, do not use an impact wrench.
To prevent warping, tighten gently before tightening firmly.
4
Install the shower base and the cover plate.
5
Connect the shower head.
6
Check the thickness of the tiles.
Please base the choice of included replacement parts on the thickness of the tiles.
The products within the thick border of the table are standard products.
7
Connect the spout.
Depending on the thickness of the tiles, replace the adapter if necessary.
9
Connect the handle.
* If it is necessary to replace the spindle and screw because of the thickness of the tiles, please use
the included maintenance tools.
8
Perform a trial run.
10
Specifications
Safety notes
Installation is only possible in frost-free rooms.
Operating pressure range:
- Recommended:
- With pressure reducing valve:
Hot water supply temperature:
Flow rate:
Supply voltage:
Power consumption:
0.05MPa 0.5bar min.
1.2MPa 12bar max.
0.2–0.3 MPa
0.2–0.3 MPa
60–85ºC
25 l/min (0.3MPa) (3bar) (spout)
9 l/min, 12 l/min (shower)
AC 100–240 V (50/60 Hz)
IPX5 (controller)
G1/2
Waterproof specifications:
Water inlet:
5
1
2
1
2
10