Vulkan V3457 Assembly Instructions

Typ
Assembly Instructions
V3457
Cylindrical Luminaire/Zylinderleuchte
060.0906.398.93 08/16
Installation Instructions · Montageanleitung
IP65 11,0
230 V
50 Hz
4 + 6
IEC 598
3,5 - 5,0 m
max. wind
projecting surface
max. Windangriffs-
fläche:
A = 0,1 m2
Dimensions [mm]
589
Ø 635
Ø 76
General safety notes
Allgemeine Sicherheitshinweise
D
GB - Installation/maintenance only by skilled personnel.
- Use luminaires only with complete protection covers!
- During overhaul/maintenance only use original parts.
- The light source contained in this luminaire shall only
be replaced by the manufacturer or his service agent or a similar
qualified person.
- If any luminaire is subsequently modified, the person
responsible for the modification shall be considered the manufacturer.
- The manufacturer bears no liability for damage caused by
inappropriate use or application.
- Montage/Wartung nur durch Fachkräfte.
- Die Leuchte darf nur mit ihren vollständigen Schutz-
abdeckungen betrieben werden!
- Bei Instandsetzung/Instandhaltung nur Originalteile verwenden.
- Die Lichtquelle dieser Leuchte darf nur vom Hersteller oder einem
von ihm beauftragten Servicetechniker oder einer vergleichbar
qualifizierten Person ersetzt werden.
- Werden nachträglich Änderungen an Leuchten vorgenommen,
so gilt derjenige als Hersteller, der diese Änderung vornimmt.
- Der Hersteller übernimmt keine Haftung für Schäden, die
durch unsachgemäßen Einsatz entstehen.
Nordeon GmbH
Rathenaustraße 2-6
D-31832 Springe
Germany
Phone +49(0)5041 75 0
www.nordeon.com/www.vulkan.eu
Leuchte mit Zündgerät
Vor Öffnen Spannung
abschalten!
Switch off mains supply
before opening!
Luminaire with high voltage
ignitor
Lamp technologies/Konventionelle Bestückung
Lamp/Lampe
HSE-E/T
(Natriumhochdruck)
Nominal
power
Nenn-
leistung
System
power
System-
leistung
Mounting
start page
Montage
ab Seite
CDO-ET/TT
(Halogenmetalldampf)
LED technologies (driver 40 W)
LED-Bestückung (Treiber 40 W)
12 W - 38 W
(High-pressure sodium)
(Metal halide)
Inrush Current:
Einschaltstrom:
Max. drivers on MCB (16 A type-B): max. 21
Max. Treiber MCB (16 A Typ-B): max. 21
Ipeak
max. 21 A/ 300
µ
s @ 230V
max. 21 A/ 300
µ
s @ 230V
Twidth
65 W
85 W
65/85 W
85/65 W
85 W
2
2
2
2
2
3
50 W
70 W
50/70 W
70/50 W
70 W
3x
5
6
3x
3x
5
6
17 Nm
3x
or/oder
or/oder
Mounting/Montage
2
HSE-E/T + CDO-ET/TT Pos. 1 - 7
LED............................... Pos. 4 - 7
1.
3.
2.
4
17 Nm
4
3x
3
Mounting/Montage
4.
5.
6.
Electrical connection/Elektrischer Anschluss
L
N
E
...MT-R / ...MS-R
...MT-R / ...MS-R
75
45 8+2
LL
N
ST
N
EL
L
ST
8+2
45
75
45 8+2
L
N
75
45 8+2
45 8+2 45 8+2
L
N
L
ST
N
EL
ST
L
L = max.
l
oad / Ganznacht
, L
ST
=
power reduction
/
Halb
nacht
4
100%
12:00
80%
60%
40%
20%
0%
14:00 16:00 18:00 20:00 22:00 00:00 2:00 4:00 6:00 8:00 10:00 12:00
15:00
T1 T2 T3 T4 T5
D1
D2
D3
D4
D5
LRA2
20:00 10:00
6:00
70%
50%
100%
12:00
80%
60%
40%
20%
0%
14:00 16:00 18:00 20:00 22:00 00:00 2:00 4:00 6:00 8:00 10:00 12:00
15:00 23:00
T1 T2 T3 T4 T5
D1
D2
D3
D4
LRA3
21:00 10:005:00
60%
30%
100%
12:00
80%
60%
40%
20%
0%
14:00 16:00 18:00 20:00 22:00 00:00 2:00 4:00 6:00 8:00 10:00 12:00
15:00 22:00
T1 T2 T3 T4 T5
D1
D2
D3
D4
D5
LRA1
00:00 10:00
6:00
70%
50%
saving
(Power reduction/
Leistungsreduktion)
LRA - Light regulation antarkic /Autarke Lichtsteuerung
saving
(Power reduction/
Leistungsreduktion)
saving
(Power reduction/
Leistungsreduktion)
5:00
5:00
6:00
D5
23:00
LRT - Light regulation twin phases/Leistungsreduzierung mit Steuerphase
Light regulation for LED version
Leistungsreduzierung bei LED-Ausführung
Max. load
Volllast
= 100%
N
L
Power reduction
Leistungsreduzierung
N
L
V3457 V3457
L
ST
L
ST